Cardiac Scan: A Non-contact and Continuous Heart-based User Authentication System
The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
Continuous authentication is of great importance to maintain the security level of a system throughout the login session. The goal of this work is to investigate a trustworthy, continuous, and non-contact user authentication approach based on a heart-related biometric that works in a daily-life environment. To this end, we present a novel, continuous authentication system, namely Cardiac Scan, based on geometric and non-volitional features of the cardiac motion. Cardiac motion is an automatic heart deformation caused by self-excitement of the cardiac muscle, which is unique to each user and is difficult (if not impossible) to counterfeit. Cardiac Scan features intrinsic liveness detection, unobtrusiveness, cost-effectiveness, and high usability. We prototype a remote, high-resolution cardiac motion sensing system based on the smart DC-coupled continuous-wave radar. Fiducial-based invariant identity descriptors of cardiac motion are extracted after the radar signal demodulation. We conduct a pilot study with 78 subjects to evaluate Cardiac Scan in accuracy, authentication time, permanence, evaluation in complex conditions, and vulnerability. Specifically, Cardiac Scan achieves 98.61% balanced accuracy (BAC) and 4.42% equal error rate (EER) in a real-world setup. We demonstrate that Cardiac Scan is a robust and usable continuous authentication system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939 · cited 1×
“, a Butterworth bandpass filter) and 2) adaptive noise canceling techniques [86] (e.”
Method(2010) · Cited by 1,697
Detection of ECG characteristic points using wavelet transforms
Li, C., Zheng, C., & Tai, C. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362922 · Cited by 1,597 · cited 1×
“Also, other methods, such as wavelet transformation [42] and area calculation upon phase portraits [65], will be further explored improve the system accuracy.”
MethodSelf-citationGuyton and Hall: Textbook of Medical Physiology
Khonsary, S. (2017) · Surgical Neurology International · doi:10.4103/sni.sni_327_17 · Cited by 1,394 · cited 2×
“Therefore, the cardiac motion is a unique identity marker for each individual [27].”
BackgroundFiltering the surface EMG signal: Movement artifact and baseline noise contamination
De Luca, C. J., Donald Gilmore, L., Kuznetsov, M., & Roy, S. H. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.01.027 · Cited by 1,277 · cited 1×
“These techniques have also been successfully applied in bio-artifact reduction [19, 87].”
MethodGanong's Review of Medical Physiology
Barrett, K. E. (2009) · Repository of the University of Ljubljana (University of Ljubljana) · Cited by 1,153
Understanding, scoping and defining user experience: a survey approach
Law, E. L.-C., Roto, V., Hassenzahl, M., Vermeeren, A. P. O. S., & Kort, J. (2009) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1518701.1518813 · Cited by 1,127 · cited 1×
“Typically, the user experience can be defined as: a person’s perceptions and responses that result from the use and/or anticipated use of a product, system or service [36].”
BackgroundWhole-home gesture recognition using wireless signals
Pu, Q., Gupta, S., Gollakota, S., & Patel, S. (2013) · Proceedings of the 19th annual international conference on Mobile computing & networking - MobiCom '13 · doi:10.1145/2500423.2500436 · Cited by 1,109
ECG analysis: a new approach in human identification
Biel, L., Pettersson, O., Philipson, L., & Wide, P. (2001) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.930458 · Cited by 949
Smart Homes that Monitor Breathing and Heart Rate
Adib, F., Mao, H., Kabelac, Z., Katabi, D., & Miller, R. C. (2015) · Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702200 · Cited by 916 · cited 1×
“showed that a radio-based sensing system can collect physiological information, such as respiration, heartbeat, for health monitoring [2].”
Background
Cited by
A survey on privacy and security of Internet of Things
Ogonji, M. M., Okeyo, G., & Wafula, J. M. (2020) · Computer Science Review · doi:10.1016/j.cosrev.2020.100312 · Cited by 230
MultiSense: Enabling Multi-person Respiration Sensing with Commodity WiFi
Zeng, Y., Wu, D., Xiong, J., Liu, J., Liu, Z., & Zhang, D. (2020) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3411816 · Cited by 227
“To achieve this goal, we first apply the extended differentiate and cross-multiply (DACM) algorithm proposed in [17] to estimate the rotation direction of the respiration signal in complex plane.”
MethodRadar-Based Monitoring of Vital Signs: A Tutorial Overview
Paterniani, G., Sgreccia, D., Davoli, A., Guerzoni, G., Di Viesti, P., Valenti, A. C., Vitolo, M., Vitetta, G. M., & Boriani, G. (2023) · Proceedings of the IEEE · doi:10.1109/jproc.2023.3244362 · Cited by 201
“The use of a CW Doppler radar device for heart- and breathing-based user authentication has been investigated in [140] and [144] and in [145], [146], and [147], respectively.”
MethodMoVi-Fi: motion-robust vital signs waveform recovery via deep interpreted RF sensing
Chen, Z., Zheng, T., Cai, C., & Luo, J. (2021) · Proceedings of the 27th Annual International Conference on Mobile Computing and Networking · doi:10.1145/3447993.3483251 · Cited by 192
“, [3, 17, 29, 36, 53, 61]): whereas the former focuses on developing radars and equip them with proper signal processing algorithms, the latter aims to build working prototypes based on commercial-grade RF platforms.”
BackgroundInfluentialWireless communications sensing and security above 100 GHz
Jornet, J. M., Knightly, E. W., & Mittleman, D. M. (2023) · Nature Communications · doi:10.1038/s41467-023-36621-x · Cited by 169
“Today ’ sRFsensingapplicationsarequiteimpressiveandinclude monitoring people ina roombehind a wall 71 and monitoring individual heart rate 72 .”
BackgroundCardiacWave: A mmWave-based Scheme of Non-Contact and High-Definition Heart Activity Computing
Xu, C., Li, H., Li, Z., Zhang, H., Rathore, A. S., Chen, X., Wang, K., Huang, M.-C., & Xu, W. (2021) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3478127 · Cited by 49
Self-citation
Metadata
- Authors
- Lin, F., Song, C., Zhuang, Y., Xu, W., Li, C., & Ren, K.
- Venue
- Proceedings of the 23rd Annual International Conference on Mobile Computing and Networking
- Publisher
- ACM
- Published
- 2017-10-04
- Pages
- 315-328
- ISSN
- 1543-5679 (ISSN-L)
- OpenAlex
- W2762561030
- Cited by
- 179
- References
- 63
- FWCI
- 11.55
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.