Cardiac Scan: A Non-contact and Continuous Heart-based User Authentication System
The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
Continuous authentication is of great importance to maintain the security level of a system throughout the login session. The goal of this work is to investigate a trustworthy, continuous, and non-contact user authentication approach based on a heart-related biometric that works in a daily-life environment. To this end, we present a novel, continuous authentication system, namely Cardiac Scan, based on geometric and non-volitional features of the cardiac motion. Cardiac motion is an automatic heart deformation caused by self-excitement of the cardiac muscle, which is unique to each user and is difficult (if not impossible) to counterfeit. Cardiac Scan features intrinsic liveness detection, unobtrusiveness, cost-effectiveness, and high usability. We prototype a remote, high-resolution cardiac motion sensing system based on the smart DC-coupled continuous-wave radar. Fiducial-based invariant identity descriptors of cardiac motion are extracted after the radar signal demodulation. We conduct a pilot study with 78 subjects to evaluate Cardiac Scan in accuracy, authentication time, permanence, evaluation in complex conditions, and vulnerability. Specifically, Cardiac Scan achieves 98.61% balanced accuracy (BAC) and 4.42% equal error rate (EER) in a real-world setup. We demonstrate that Cardiac Scan is a robust and usable continuous authentication system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939 · cited 1×
“, a Butterworth bandpass filter) and 2) adaptive noise canceling techniques [86] (e.”
Method(2010) · Cited by 1,697
Detection of ECG characteristic points using wavelet transforms
Li, C., Zheng, C., & Tai, C. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362922 · Cited by 1,597 · cited 1×
“Also, other methods, such as wavelet transformation [42] and area calculation upon phase portraits [65], will be further explored improve the system accuracy.”
MethodSelf-citationGuyton and Hall: Textbook of Medical Physiology
Khonsary, S. (2017) · Surgical Neurology International · doi:10.4103/sni.sni_327_17 · Cited by 1,394 · cited 2×
“Therefore, the cardiac motion is a unique identity marker for each individual [27].”
BackgroundFiltering the surface EMG signal: Movement artifact and baseline noise contamination
De Luca, C. J., Donald Gilmore, L., Kuznetsov, M., & Roy, S. H. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.01.027 · Cited by 1,277 · cited 1×
“These techniques have also been successfully applied in bio-artifact reduction [19, 87].”
MethodGanong's Review of Medical Physiology
Barrett, K. E. (2009) · Repository of the University of Ljubljana (University of Ljubljana) · Cited by 1,153
Understanding, scoping and defining user experience: a survey approach
Law, E. L.-C., Roto, V., Hassenzahl, M., Vermeeren, A. P. O. S., & Kort, J. (2009) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1518701.1518813 · Cited by 1,127 · cited 1×
“Typically, the user experience can be defined as: a person’s perceptions and responses that result from the use and/or anticipated use of a product, system or service [36].”
BackgroundWhole-home gesture recognition using wireless signals
Pu, Q., Gupta, S., Gollakota, S., & Patel, S. (2013) · Proceedings of the 19th annual international conference on Mobile computing & networking - MobiCom '13 · doi:10.1145/2500423.2500436 · Cited by 1,109
ECG analysis: a new approach in human identification
Biel, L., Pettersson, O., Philipson, L., & Wide, P. (2001) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.930458 · Cited by 949
Smart Homes that Monitor Breathing and Heart Rate
Adib, F., Mao, H., Kabelac, Z., Katabi, D., & Miller, R. C. (2015) · Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702200 · Cited by 916 · cited 1×
“showed that a radio-based sensing system can collect physiological information, such as respiration, heartbeat, for health monitoring [2].”
BackgroundAnalysis of the phase unwrapping algorithm
Itoh, K. (1982) · Applied Optics · doi:10.1364/ao.21.002470 · Cited by 887 · cited 1×
“Once Paper Session VII: Leaks, Plugs, Alice and Bob the demodulation exceeds this range, phase unwrapping is required, which is challenging in practical detection when noise is strong and the movement amplitude is large [29].”
BackgroundFrank, M., Biedert, R., Ma, E., Martinovic, I., & Song, D. (2013) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2012.2225048 · Cited by 844 · cited 1×
“Behavioral screentouch features have also been explored for continuous authentication (e.g., Frank et al. [24] and Chan et al. [13]).”
BackgroundIsrael, S. A., Irvine, J. M., Cheng, A., Wiederhold, M. D., & Wiederhold, B. K. (2005) · Pattern Recognition · doi:10.1016/j.patcog.2004.05.014 · Cited by 669 · cited 2×
“cal information that is unique and non-volatile for individuals, and are also independent of the sensor location or state of the individual such as anxiety, nervousness, or excitement [28].”
BackgroundDroitcour, A. D., Boric-Lubecke, O., Lubecke, V. M., Lin, J., & Kovacs, G. T. A. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.823552 · Cited by 662
Eyeblink-based Anti-Spoofing in Face Recognition from a Generic Webcamera
Pan, G., Sun, L., Wu, Z., & Lao, S. (2007) · 2007 IEEE 11th International Conference on Computer Vision · doi:10.1109/iccv.2007.4409068 · Cited by 658
Arctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems
Park, B.-K., Boric-Lubecke, O., & Lubecke, V. M. (2007) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2007.895653 · Cited by 604
Face Liveness Detection from a Single Image with Sparse Low Rank Bilinear Discriminative Model
Tan, X., Li, Y., Liu, J., & Jiang, L. (2010) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-15567-3_37 · Cited by 521 · cited 1×
“The general idea of anti-spoofing is liveness detection [52, 80].”
BackgroundEmotion recognition using wireless signals
Zhao, M., Adib, F., & Katabi, D. (2016) · Proceedings of the 22nd Annual International Conference on Mobile Computing and Networking · doi:10.1145/2973750.2973762 · Cited by 461 · cited 1×
“Zhao et al. proposed EQ-Radio to infer a person’s emotions from RF signals reflected off the body [90].”
BackgroundRandom Body Movement Cancellation in Doppler Radar Vital Sign Detection
Li, C., & Lin, J. (2008) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2008.2007139 · Cited by 448 · cited 5×
“However, existing cancellation approaches either compromise the quality of the baseband signals [40] or require sweeping the carrier frequency and adjusting the target position [82], which is not applicable to capture the high-fidelity cardiac motion in a real-world setup.”
BackgroundMethodInfluentialSelf-citationChen, K.-M., Huang, Y., Zhang, J., & Norman, A. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.817625 · Cited by 445 · cited 1×
“[16, 21, 41, 48, 49].”
HMOG: New Behavioral Biometric Features for Continuous Authentication of Smartphone Users
Sitova, Z., Sedenka, J., Yang, Q., Peng, G., Zhou, G., Gasti, P., & Balagani, K. S. (2016) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2015.2506542 · Cited by 398 · cited 1×
“used hand gestures for continuous smartphone authentication [76], however, these methods require users to be obligated to continuously interact with systems for authentication.”
MethodECG Biometric Recognition: A Comparative Analysis
Odinaka, I., Lai, P.-H., Kaplan, A. D., O'Sullivan, J. A., Sirevaag, E. J., & Rohrbaugh, J. W. (2012) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2012.2215324 · Cited by 356
Microwave sensing of physiological movement and volume change: A review
Lin, J. C. (1992) · Bioelectromagnetics · doi:10.1002/bem.2250130610 · Cited by 299 · cited 1×
“Traditionally, to detect the weak physiological signal x(t), the small-angle approach was used [21, 40, 41, 48], which suffers from two inherent problems.”
MethodHandbook of Biometric Anti-Spoofing: Trusted Biometrics under Spoofing Attacks
(2014) · Advances in Computer Vision and Pattern Recognition · doi:10.1007/978-1-4471-6524-8 · Cited by 270
ECG Biometric Recognition Without Fiducial Detection
Plataniotis, K. N., Hatzinakos, D., & Lee, J. K. M. (2006) · 2006 Biometrics Symposium: Special Session on Research at the Biometric Consortium Conference · doi:10.1109/bcc.2006.4341628 · Cited by 243 · cited 1×
“For fiducial descriptors, there exist literature [3, 44, 50, 64] where multiple cardiac cycles were used.”
BackgroundWang, G., Zou, Y., Zhou, Z., Wu, K., & Ni, L. M. (2014) · Proceedings of the 20th annual international conference on Mobile computing and networking · doi:10.1145/2639108.2639112 · Cited by 241 · cited 1×
“Wang et al. studied radio signal analysis for people localization and motion tracking [83].”
BackgroundSoft Biometric Traits for Continuous User Authentication
Niinuma, K., Park, U., & Jain, A. K. (2010) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2010.2075927 · Cited by 202 · cited 1×
“used the color of user’s clothing and facial skin for continuous monitoring [56].”
MethodLi, C., & Lin, J. (2008) · 2008 IEEE MTT-S International Microwave Symposium Digest · doi:10.1109/mwsym.2008.4633229 · Cited by 192 · cited 1×
“When the body is drifting toward one radar, it is moving away from the other; whereas heartbeat presents similar expansion/contraction patterns to the two radars [39].”
BackgroundSelf-citationWang, F.-K., Horng, T.-S., Peng, K.-C., Jau, J.-K., Li, J.-Y., & Chen, C.-C. (2011) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2011.2171712 · Cited by 179
SleepSense: A Noncontact and Cost-Effective Sleep Monitoring System
Lin, F., Zhuang, Y., Song, C. L., Wang, A., Li, Y., Gu, C., Li, C., & Xu, W. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2541680 · Cited by 150 · cited 1×
“Then two baseband signals, the in-phase signal I ( t ) and quadrature signal Q ( t ) can be derived from R ( t ) [47]: is the quadrature signal: where A I and A Q are the amplitude of the in-phase signal and the quadrature signal, respectively.”
BackgroundSelf-citationCounterfeit iris detection based on texture analysis
Wei, Z., Qiu, X., Sun, Z., & Tan, T. (2008) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.2008.4761673 · Cited by 142 · cited 1×
“Wei et al. detected counterfeit iris through texture analysis [84].”
BackgroundTotal heart volume variation throughout the cardiac cycle in humans
Carlsson, M., Cain, P., Holmqvist, C., Stahlberg, F., Lundback, S., & Arheden, H. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01125.2003 · Cited by 137 · cited 1×
“) and 3D deformation of the heart [12].”
BackgroundECG Based Recognition Using Second Order Statistics
Agrafioti, F., & Hatzinakos, D. (2008) · Annual Communication Networks and Services Research Conference (CNSR) · doi:10.1109/cnsr.2008.38 · Cited by 137 · cited 1×
“For fiducial descriptors, there exist literature [3, 44, 50, 64] where multiple cardiac cycles were used.”
BackgroundA Human ECG Identification System Based on Ensemble Empirical Mode Decomposition
Zhao, Z., Yang, L., Chen, D., & Luo, Y. (2013) · Sensors · doi:10.3390/s130506832 · Cited by 128 · cited 1×
“extracted ECG feature for a human identification system by decomposing ECG signal into intrinsic mode functions using ensemble empirical mode decomposition [91].”
MethodDoppler and direction-of-arrival (DDOA) radar for multiple-mover sensing
Lin, A., & Ling, H. (2007) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.2007.4407473 · Cited by 123
Robust ECG Biometrics by Fusing Temporal and Cepstral Information
Li, M., & Narayanan, S. S. (2010) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.2010.330 · Cited by 122 · cited 1×
“For fiducial descriptors, there exist literature [3, 44, 50, 64] where multiple cardiac cycles were used.”
BackgroundElectrocardiogram (ECG) Biometric Authentication Using Pulse Active Ratio (PAR)
Safie, S. I., Soraghan, J. J., & Petropoulakis, L. (2011) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2011.2162408 · Cited by 116 · cited 10×
“generated ECG features for authentication by using a pulse active ratio (PAR) technique [70].”
MethodInfluentialContinuous user authentication using multi-modal biometrics
Saevanee, H., Clarke, N., Furnell, S., & Biscione, V. (2015) · Computers & Security · doi:10.1016/j.cose.2015.06.001 · Cited by 109 · cited 1×
“utilize a text-based multimodal biometric including linguistic analysis, keystroke dynamics and behavioural profiling [69].”
MethodA digital signal processor for Doppler radar sensing of vital signs
Lohman, B., Borić-Lubecke, O., Lubecke, V. M., Ong, P. W., & Sondhi, M. M. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2002.1044188 · Cited by 107
Broken Hearted: How To Attack ECG Biometrics
Eberz, S., Paoletti, N., Roeschlin, M., Patani, A., Kwiatkowska, M., & Martinović, I. (2017) · Network and Distributed System Security Symposium · doi:10.14722/ndss.2017.23408 · Cited by 106 · cited 1×
“hardware-based arbitrary waveform generator (AWG) and a sound card based AWG software to encode and emulate a set of pulse signals for attacking heart-based biometrics on the Nymi band [22].”
Evaluation of Electrocardiogram for Biometric Authentication
Singh, Y. N., & Singh, S. (2012) · Journal of Information Security · doi:10.4236/jis.2012.31005 · Cited by 102 · cited 1×
“The system is also evaluated in combination with face and fingerprint biometrics [75].”
MethodFinger ECG signal for user authentication: Usability and performance
Silva, H., Fred, A. L. N., Lourenço, A., & Jain, A. K. (2013) · IEEE International Conference on Biometrics: Theory, Applications and Systems (BTAS) · doi:10.1109/btas.2013.6712689 · Cited by 100 · cited 1×
“Silva et al. collected ECG from fingers for user authentication [18].”
BackgroundFeasibility study of photoplethysmographic signals for biometric identification
Spachos, P., Gao, J., & Hatzinakos, D. (2011) · IEEE International Conference on Digital Signal Processing (DSP) · doi:10.1109/icdsp.2011.6004938 · Cited by 87 · cited 1×
“To improve usability, other heart-related biosignals, such as Photoplethysmogram (PPG) [71, 78, 88], carotid pulse [17, 32], and finger pulse response [67], were investigated for human identification.”
BackgroundSufi, F. K., Khalil, I., & Hu, J. (2010) · Springer eBooks · doi:10.1007/978-3-642-04117-4_17 · Cited by 85 · cited 1×
“interfered with by parameters setting [79], making non-fiducialbased methods inapplicable for continuous real-time authentication.”
Assessment of Human Respiration Patterns via Noncontact Sensing Using Doppler Multi-Radar System
Gu, C., & Li, C. (2015) · Sensors · doi:10.3390/s150306383 · Cited by 84
Self-citationPreventing Lunchtime Attacks: Fighting Insider Threats With Eye Movement Biometrics
Eberz, S., Rasmussen, K., Lenders, V., & Martinović, I. (2015) · Network and Distributed System Security Symposium · doi:10.14722/ndss.2015.23203 · Cited by 78 · cited 1×
“However, keystroke dynamics [63, 73] require the user to keep typing on the keyboard, while gaze patterns [23, 54] requires the user to face and continuously look at the screen.”
BackgroundHuman Electrocardiogram for Biometrics Using DTW and FLDA
Venkatesh, N., & Jayaraman, S. (2010) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.2010.935 · Cited by 78 · cited 2×
“To prove the identifiability in cardiac motion, dynamic time warping (DTW) [81] is used as the similarity matching metric.”
MethodKhan, H., Atwater, A., & Hengartner, U. (2014) · ACM Annual International Conference on Mobile Computing and Networking (MobiCom) · doi:10.1145/2639108.2639141 · Cited by 75 · cited 1×
“Android smartphone based on behavioral biometrics [34], yet there is no new biometrics proposed in this work.”
BackgroundEyeVeri: A secure and usable approach for smartphone user authentication
Song, C., Wang, A., Ren, K., & Xu, W. (2016) · IEEE Conference on Computer Communications (INFOCOM) · doi:10.1109/infocom.2016.7524367 · Cited by 72 · cited 1×
“Some studies leveraged eye movement biometrics (e.g., Eberz et al. [23], Mock et al. [54] and Song et al. [77]).”
BackgroundSelf-citationMeasurement of respiration rate in preterm infants by laser Doppler vibrometry
Scalise, L., Ercoli, I., Marchionni, P., & Tomasini, E. P. (2011) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2011.5966740 · Cited by 72 · cited 1×
“Compared with other techniques such as non-contact laser vibrometer [72] and infrared imager [53] that can only detect motion at body surface, it has been shown”
MethodReal-time continuous iris recognition for authentication using an eye tracker
Mock, K. J., Hoanca, B., Weaver, J., & Milton, M. (2012) · ACM SIGSAC Conference on Computer and Communications Security (CCS) · doi:10.1145/2382196.2382307 · Cited by 57 · cited 1×
“However, keystroke dynamics [63, 73] require the user to keep typing on the keyboard, while gaze patterns [23, 54] requires the user to face and continuously look at the screen.”
BackgroundBreath Rate Monitoring During Sleep using Near-IR Imagery and PCA
Martínez, M., & Stiefelhagen, R. (2013) · Cited by 51
Gait-Based Wi-Fi Signatures for Privacy-Preserving
Li, Y., & Zhu, T. (2016) · ACM Asia Conference on Computer and Communications Security (ASIA CCS) · doi:10.1145/2897845.2897909 · Cited by 48
Signal validation for cardiac biometrics
Agrafioti, F., & Hatzinakos, D. (2010) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2010.5495461 · Cited by 47 · cited 1×
“permanence of heart-based biometrics was discussed in early experiments in many short-term studies [4, 25, 55].”
BackgroundAuthentication using pulse-response biometrics
Martinović, I., Rasmussen, K., Roeschlin, M., & Tsudik, G. (2017) · Communications of the ACM · doi:10.1145/3023359 · Cited by 43 · cited 4×
“utilized human body pulse-response as a continuous authenticationmechanism[67].”
BackgroundMethodInfluentialMonitoring internal organ motion with continuous wave radar in CT
Pfanner, F., Maier, J., Allmendinger, T., Flohr, T. G., & Kachelrieß, M. (2013) · Medical Physics · doi:10.1118/1.4818061 · Cited by 24 · cited 1×
“that the Doppler radar sensor can directly measure the motion of internal organs [62] and heart [68, 92].”
BackgroundLi, M., & Li, X. (2014) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2014.6854306 · Cited by 22 · cited 1×
“These stages vary from person to person due to the change in size, position, anatomy of the heart, chest configuration and various other factors [43].”
BackgroundAli, Z., Payton, J., & Sritapan, V. (2016) · IEEE Security and Privacy Workshops (SPW) · doi:10.1109/spw.2016.29 · Cited by 21 · cited 1×
“Keystroke dynamics, especially the rollover pattern, have been used for continuous authentication (e.g., Pinto et al. [63], Shepherd [73], Ali et al. [6]).”
MethodMotion noise cancellation in seismocardiographic monitoring of moving subjects
Yang, C., & Tavassolian, N. (2015) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2015.7348361 · Cited by 17
ECG for blind identity verification in distributed systems
Gao, J., Agrafioti, F., Mohammadzade, H., & Hatzinakos, D. (2011) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2011.5946882 · Cited by 17 · cited 1×
“The permanence of heart-based biometrics was discussed in early experiments in many short-term studies [4, 25, 55].”
BackgroundFree Typed Text Using Keystroke Dynamics for Continuous Authentication
Pinto, P., Patrão, B., & Santos, H. (2014) · Lecture notes in computer science · doi:10.1007/978-3-662-44885-4_3 · Cited by 13 · cited 1×
“However, keystroke dynamics [63, 73] require the user to keep typing on the keyboard, while gaze patterns [23, 54] requires the user to face and continuously look at the screen.”
BackgroundSleepSense: Non-invasive sleep event recognition using an electromagnetic probe
Zhuang, Y., Song, C. L., Wang, A., Lin, F., Li, Y., Gu, C., Li, C., & Xu, W. (2015) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2015.7299364 · Cited by 11
Self-citationTouchpad Input for Continuous Biometric Authentication
Chan, A. Y., Halevi, T., & Memon, N. D. (2014) · Lecture notes in computer science · doi:10.1007/978-3-662-44885-4_7 · Cited by 8 · cited 1×
“Behavioral screentouch features have also been explored for continuous authentication (e.g., Frank et al. [24] and Chan et al. [13]).”
Background
Cited by
A survey on privacy and security of Internet of Things
Ogonji, M. M., Okeyo, G., & Wafula, J. M. (2020) · Computer Science Review · doi:10.1016/j.cosrev.2020.100312 · Cited by 230
MultiSense: Enabling Multi-person Respiration Sensing with Commodity WiFi
Zeng, Y., Wu, D., Xiong, J., Liu, J., Liu, Z., & Zhang, D. (2020) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3411816 · Cited by 227
“To achieve this goal, we first apply the extended differentiate and cross-multiply (DACM) algorithm proposed in [17] to estimate the rotation direction of the respiration signal in complex plane.”
MethodMoVi-Fi: motion-robust vital signs waveform recovery via deep interpreted RF sensing
Chen, Z., Zheng, T., Cai, C., & Luo, J. (2021) · Proceedings of the 27th Annual International Conference on Mobile Computing and Networking · doi:10.1145/3447993.3483251 · Cited by 192
“, [3, 17, 29, 36, 53, 61]): whereas the former focuses on developing radars and equip them with proper signal processing algorithms, the latter aims to build working prototypes based on commercial-grade RF platforms.”
BackgroundInfluentialCardiacWave: A mmWave-based Scheme of Non-Contact and High-Definition Heart Activity Computing
Xu, C., Li, H., Li, Z., Zhang, H., Rathore, A. S., Chen, X., Wang, K., Huang, M.-C., & Xu, W. (2021) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3478127 · Cited by 49
Self-citation
Metadata
- Authors
- Lin, F., Song, C., Zhuang, Y., Xu, W., Li, C., & Ren, K.
- Venue
- Proceedings of the 23rd Annual International Conference on Mobile Computing and Networking
- Publisher
- ACM
- Published
- 2017-10-04
- Pages
- 315-328
- ISSN
- 1543-5679 (ISSN-L)
- OpenAlex
- W2762561030
- Cited by
- 179
- References
- 63
- FWCI
- 11.55
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›