Design Guideline for Developing Safe Systems that Apply Electricity to the Human Body
The DOI matches its Crossref record; 189 of the 190 references it cites were found in a registry or an index.
Abstract
The human body has unique electrical characteristics. These characteristics have been investigated in various studies in human-computer interaction (HCI) and related research fields. Such studies include applications for using the body as a conductive lead for transmission or electric field sensing and activating human muscles or organs. However, electricity is not completely safe for the human body; therefore, to avoid harming users, careful consideration is essential when developing such devices. The knowledge required for such consideration is spread throughout a large number research fields, and it can be difficult for researchers in the HCI field to comprehend all of them. The purpose of this article is to support researchers in developing systems that apply electricity to the human body and to serve as a basis for further research. This article reviews previous research pertaining to HCI in which users come into contact with electricity. In addition, considerations of how and where this type of research can be expanded, along with guidelines grounded in other fields for designing systems safely and addressing ethical concerns, are presented. An understanding of the field and of the related safety issues will enhance the understanding of limitations and potential and can clarify the design space.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Nevertheless, the human epidermis has rather large resistances, which makes it quite challenging to decide an appropriate voltage for creating desired stimulations without pain (13, 14).”
From Self-powered electro-tactile system for virtual tactile experiences (2021) · cites this paper as [13]
In the citing paper
“It is worth mentioning that the current of discharge, especially powered by TENG, is much smaller than that of the reported ET display [5 mA of the ET device (10) and 0.96 to 1.83 mA of the ET tattoo (14)], contributing to safe stimulation to skin (under 10 mA) (13)”
From Self-powered electro-tactile system for virtual tactile experiences (2021) · cites this paper as [13]
Citations
Cites
The Computer for the 21st Century
Weiser, M. (1991) · Scientific American · doi:10.1038/scientificamerican0991-94 · Cited by 10,017
The American Psychological Association
Langfeld, H. S. (1919) · Science · doi:10.1126/science.49.1254.51 · Cited by 7,475
Ahlbom, A. (1998) · Health Physics · Cited by 5,817
“Ethical Principles of Psychologists and Code of Conduct”
(2000) · Ethical Reasoning in the Mental Health Professions · doi:10.4324/9781482274400-4 · Cited by 4,251
The 2007 recommendations of the International Commission on Radiological Protection
Valentin, J. (2007) · Elsevier eBooks · Cited by 4,105
The dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156 · cited 1×
“Another interesting application is to use the dielectric properties of tissues [42].”
BackgroundTranscranial direct current stimulation: State of the art 2008
Nitsche, M. A., Cohen, L. G., Wassermann, E. M., Priori, A., Lang, N., Antal, A., Paulus, W., Hummel, F., Boggio, P. S., Fregni, F., et al. (2008) · Brain Stimulation · doi:10.1016/j.brs.2008.06.004 · Cited by 3,057
Ethical principles for medical research involving human subjects
(2003) · Manual for Research Ethics Committees · doi:10.1017/cbo9780511550089.027 · Cited by 2,585
2007 Recommendations of the International Commission on Radiological Protection
Publ., I. (2008) · Annals of the ICRP · Cited by 1,788
American Conference of Governmental Industrial Hygienists
(1987) · Applied Industrial Hygiene · doi:10.1080/08828032.1987.10389787 · Cited by 1,442
Research works printed but not linked: 29
- Reena Antil , Pinki, and Sonal Beniwal . 2013 . Red tacton : A review . International Journal of Science and Engineering Research 4 , 3 (Mar. 2013), 1--7. Reena Antil, Pinki, and Sonal Beniwal. 2013. Red tacton : A review. International Journal of Science and Engineering Research 4, 3 (Mar. 2013), 1--7.
- ESD Association . 2010. Fundamentals of Electrostatic Discharge Part 5: Device Sensitivity and Testing . EOS/ESD Association, Inc. ESD Association. 2010. Fundamentals of Electrostatic Discharge Part 5: Device Sensitivity and Testing. EOS/ESD Association, Inc.
- E. K. Greenwald . 1991. Electrical Hazards and Accidents . Wiley , 28--36. E. K. Greenwald. 1991. Electrical Hazards and Accidents. Wiley, 28--36.
- Inc. H2L. 2016 . UnlimitedHand. Retrieved from http://unlimitedhand.com/en/. Last Accessed May 23, 2018. Inc. H2L. 2016. UnlimitedHand. Retrieved from http://unlimitedhand.com/en/. Last Accessed May 23, 2018.
- Tomita Hiroshi . 1968 . Facial paralysis and electrogustometry (in Japanese) . The Society of Practical Otolaryngology 61 , 4 (1968), 419 -- 429 . Tomita Hiroshi. 1968. Facial paralysis and electrogustometry (in Japanese). The Society of Practical Otolaryngology 61, 4 (1968), 419--429.
- Tomita Hiroshi . 2011 . Whole Picture of Dysgeusia (in Japanese). Shindan to Chiryo sha, Inc ., Chapter 10 , 101 -- 106 . Tomita Hiroshi. 2011. Whole Picture of Dysgeusia (in Japanese). Shindan to Chiryo sha, Inc., Chapter 10, 101--106.
- IEC. 2017 . World Plugs. (2017). Retrieved from http://www.iec.ch/worldplugs/list_byfrequency.htm. Last Accessed May 23, 2018. IEC. 2017. World Plugs. (2017). Retrieved from http://www.iec.ch/worldplugs/list_byfrequency.htm. Last Accessed May 23, 2018.
- Japanese Industrial Standards 2003 . Electric Therapy Apparatus for Home Use . JIS T 2003 : 2011 . Japanese Industrial Standards 2003. Electric Therapy Apparatus for Home Use. JIS T 2003:2011.
- Hiroyuki Kajimoto , Naoki Kawakami , and Susumu Tachi . 2004 . Electro-tactile display with tactile primary color approach . In Proceedings of International Conference on Intelligent Robots and Systems (IROS’04) . Hiroyuki Kajimoto, Naoki Kawakami, and Susumu Tachi. 2004. Electro-tactile display with tactile primary color approach. In Proceedings of International Conference on Intelligent Robots and Systems (IROS’04).
- Pedro Lopes and Lining Yao . 2016 . UIST 2016 Student Innovation Contest. (2016 ). DOI:http://dx.doi.org/uist2016/contest Pedro Lopes and Lining Yao. 2016. UIST 2016 Student Innovation Contest. (2016). DOI:http://dx.doi.org/uist2016/contest
- Pedro Lopes Doga Yuksel and Sijing You. 2016. openEMSstim: Open-hardware module to adjust the intensity of EMS/TENS stimulators. (2016). DOI:http://dx.doi.org/PedroLopes/openEMSstim Pedro Lopes Doga Yuksel and Sijing You. 2016. openEMSstim: Open-hardware module to adjust the intensity of EMS/TENS stimulators. (2016). DOI:http://dx.doi.org/PedroLopes/openEMSstim
- John Marx , Ron Walls , and Robert Hockberger . 2013 . Rosen’s Emergency Medicine -- Concepts and Clinical Practice (8th ed.). Saunders , Chapter 63 , 808 -- 809 . John Marx, Ron Walls, and Robert Hockberger. 2013. Rosen’s Emergency Medicine -- Concepts and Clinical Practice (8th ed.). Saunders, Chapter 63, 808--809.
- S. Monsur . 2013. Essential Topics and Cases for Anesthesia Oral Boards . LULU Press , 333. S. Monsur. 2013. Essential Topics and Cases for Anesthesia Oral Boards. LULU Press, 333.
- Hiromi Nakamura and Homei Miyashita . 2016 . A survey on physiological mechanism and characteristics of electric taste (in Japanese) . Computer Software 33 , 2 (2016), 43 -- 55 . Hiromi Nakamura and Homei Miyashita. 2016. A survey on physiological mechanism and characteristics of electric taste (in Japanese). Computer Software 33, 2 (2016), 43--55.
- National Institute of Standards and Technology (NIST). 2008. EEEL Safety Rules for Moderate and High Voltages . National Institute of Standards and Technology . National Institute of Standards and Technology (NIST). 2008. EEEL Safety Rules for Moderate and High Voltages. National Institute of Standards and Technology.
- A. Noymai , A. Hemakom , P. Israsena , S. Isaradisaikul , N. Navacharoen , S. Boonyanukul , and S. Lekagul . 2010. On engineering and user’s satisfaction of a pocket digital hearing aid: A preliminary report . In Proceedings of the 4th International Convention on Rehabilitation Engineering and Assistive Technology (iCREATe’10) . START Centre, Kaki Bukit TechPark II, Singapore. A. Noymai, A. Hemakom, P. Israsena, S. Isaradisaikul, N. Navacharoen, S. Boonyanukul, and S. Lekagul. 2010. On engineering and user’s satisfaction of a pocket digital hearing aid: A preliminary report. In Proceedings of the 4th International Convention on Rehabilitation Engineering and Assistive Technology (iCREATe’10). START Centre, Kaki Bukit TechPark II, Singapore.
- E. Rehmi Post , Babak Nivi , and Neil Gershenfeld . 2001 . Method and apparatus for transbody transmission of power and information. (2001) . US Patent 6 , 211 ,799. https://patents.google.com/patents/US6211799. E. Rehmi Post, Babak Nivi, and Neil Gershenfeld. 2001. Method and apparatus for transbody transmission of power and information. (2001). US Patent 6,211,799. https://patents.google.com/patents/US6211799.
- 10.5555/851036.856448 · doi:10.5555/851036.856448
- J. D. Ramsey and Y. C. Kwon . 1988. Simplified decision rules for predicting performance loss in the heat . In Proceedings on Heat Stress Indices. Commission of the European Communities , Luxembourg. J. D. Ramsey and Y. C. Kwon. 1988. Simplified decision rules for predicting performance loss in the heat. In Proceedings on Heat Stress Indices. Commission of the European Communities, Luxembourg.
- J. Partick Reilly . 1998 . Applied Bioelectricity -- From Electrical Stimulation to Electropathology. Springer , Chapter 2 , 45 -- 48 . J. Partick Reilly. 1998. Applied Bioelectricity -- From Electrical Stimulation to Electropathology. Springer, Chapter 2, 45--48.
- J. Partick Reilly . 1998 . Applied Bioelectricity -- From Electrical Stimulation to Electropathology. Springer , Chapter 2 , 20 -- 31 . J. Partick Reilly. 1998. Applied Bioelectricity -- From Electrical Stimulation to Electropathology. Springer, Chapter 2, 20--31.
- 10.5555/580581.856565 · doi:10.5555/580581.856565
- Kou Sakabe , Kunio Hane , and Mikio Miyata . 2012 . Body and Electromagnetic wave (in Japanese). Maruzen Publishing Co.,Ltd ., Chapter 1 , 1 -- 26 . Kou Sakabe, Kunio Hane, and Mikio Miyata. 2012. Body and Electromagnetic wave (in Japanese). Maruzen Publishing Co.,Ltd., Chapter 1, 1--26.
- SCENIHR. 2008 . Possible effects of electromagnetic fields (EMF) on human health . Toxicology 246 , 2 -- 3 (2008), 248--250. SCENIHR. 2008. Possible effects of electromagnetic fields (EMF) on human health. Toxicology 246, 2--3 (2008), 248--250.
- Mary Lou Sole , Deborah Goldenberg Klein , and Marthe J. Moseley . 2013 . Introduction to Critical Care Nursing (6th ed.). Saunders , Chapter 20 , 615 -- 617 . Mary Lou Sole, Deborah Goldenberg Klein, and Marthe J. Moseley. 2013. Introduction to Critical Care Nursing (6th ed.). Saunders, Chapter 20, 615--617.
- Yuri Suzuki Oliver Bau Ivan Poupyrev Matt Glisson and Alexander Rothera. 2013. Ishin-Den-Shin: Transmitting Sound Through Touch. (2013). DOI:http://dx.doi.org/project/ishin-den-shin/. Yuri Suzuki Oliver Bau Ivan Poupyrev Matt Glisson and Alexander Rothera. 2013. Ishin-Den-Shin: Transmitting Sound Through Touch. (2013). DOI:http://dx.doi.org/project/ishin-den-shin/.
- Takehiko Takahashi . 2003 . Practical Knowledge for Grounding and Equipotential Bonding Design (in Japanese). Ohmsha , Chapter 1 , 8 -- 23 . Takehiko Takahashi. 2003. Practical Knowledge for Grounding and Equipotential Bonding Design (in Japanese). Ohmsha, Chapter 1, 8--23.
- Koreyuki Taketani . 2001 . Electric Safety by IEC Standards (in Japanese). Riko Tosho , Chapter 4 , 27 -- 41 . Koreyuki Taketani. 2001. Electric Safety by IEC Standards (in Japanese). Riko Tosho, Chapter 4, 27--41.
- H. Tomiyama , H. Tomita , and Y. Okuda . 1971 . Normal level of electric taste (in Japanese) . Journal of the Oto--Rhino--Laryngological Society of Japan (Nippon Jibiinkoka Gakkai Kaiho) 74 , 11 (1971), 1580 -- 1587 . H. Tomiyama, H. Tomita, and Y. Okuda. 1971. Normal level of electric taste (in Japanese). Journal of the Oto--Rhino--Laryngological Society of Japan (Nippon Jibiinkoka Gakkai Kaiho) 74, 11 (1971), 1580--1587.
Cited by
Self-powered electro-tactile system for virtual tactile experiences
Shi, Y., Wang, F., Tian, J., Li, S., Fu, E., Nie, J., Lei, R., Ding, Y., Chen, X., & Wang, Z. L. (2021) · Science Advances · doi:10.1126/sciadv.abe2943 · Cited by 251
“83 mA of the ET tattoo (14)], contributing to safe stimulation to skin (under 10 mA) (13) as well as the simplification of the two-electrode mode to one-electrode fabrication.”
BackgroundHaptic Sensing and Feedback Techniques toward Virtual Reality
Shi, Y., & Shen, G. (2024) · Research · doi:10.34133/research.0333 · Cited by 145
“They used the controlled distance to regulate the current induced into skin, resulting in an ultralow current of 25 μ A, which was remarkably lower than the safety current threshold current (10 mA) on skin [148].”
BackgroundIncreasing Electrical Muscle Stimulation's Dexterity by means of Back of the Hand Actuation
Takahashi, A., Brooks, J., Kajimoto, H., & Lopes, P. (2021) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3411764.3445761 · Cited by 78
Literature Reviews in HCI: A Review of Reviews
Stefanidi, E., Bentvelzen, M., Woźniak, P. W., Kosch, T., Woźniak, M. P., Mildner, T., Schneegass, S., Müller, H., & Niess, J. (2023) · Proceedings of the 2023 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3544548.3581332 · Cited by 66
DextrEMS: Increasing Dexterity in Electrical Muscle Stimulation by Combining it with Brakes
Nith, R., Teng, S.-Y., Li, P., Tao, Y., & Lopes, P. (2021) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/3472749.3474759 · Cited by 65
On the Safety of Human Body Communication
Maity, S., Nath, M., Bhattacharya, G., Chatterjee, B., & Sen, S. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2986464 · Cited by 62
“[22] looks into the different types of interaction between human and computers that require electrical signal transmission through the body and analyzes the safety aspect of some of those studies in terms of the amount of current being injected into the body.”
BackgroundYoon, S. H., Ma, S., Lee, W. S., Thakurdesai, S., Sun, D., Ribeiro, F., & Holbery, J. D. (2019) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/3332165.3347888 · Cited by 45
“Still, it is challenging to employ these devices for general user interaction purposes because of a safety concern resulted from high operating volt ages (>1 kV) [33].”
BackgroundElectrical Head Actuation: Enabling Interactive Systems to Directly Manipulate Head Orientation
Tanaka, Y., Nishida, J., & Lopes, P. (2022) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3491102.3501910 · Cited by 45
“To ensure operational safety during our head actuation via EMS to the neck, we follow the established safety guideline around EMS [28] by using a medically-compliant stimulator throughout the study [50].”
MethodUser Authentication via Electrical Muscle Stimulation
Chen, Y., Yang, Z., Abbou, R., Lopes, P., Zhao, B. Y., & Zheng, H.-T. (2021) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3411764.3445441 · Cited by 42
“Electrode pairs are typically driven using safe and medical compliant muscle stimulators [37].”
BackgroundDifficulties of Measuring Culture in Privacy Studies
Anaraky, R. G., Yao, L., & Knijnenburg, B. P. (2021) · Proceedings of the ACM on Human-Computer Interaction · doi:10.1145/3479522 · Cited by 40
Raben, H., Kämmerer, P. W., Bader, R., & van Rienen, U. (2019) · Applied Sciences · doi:10.3390/app9102160 · Cited by 34
“244 mA flowing between electrode and tissue may be perceptible according to [67] (reproduced in [68]); however, this value is far from the threshold for muscular reactions (5 mA [67]).”
BackgroundElectricItch: Skin Irritation as a Feedback Modality
Pohl, H., & Hornbæk, K. (2018) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/3242587.3242647 · Cited by 34
“As described above, this design includes several components to ensure the generated signal is limited to safe current and voltage levels (see [26, 48] for overviews of applicable safety considerations).”
BackgroundIn-pulse: inducing fear and pain in virtual experiences
Kono, M., Miyaki, T., & Rekimoto, J. (2018) · ACM Symposium on Virtual Reality Software and Technology (VRST) · doi:10.1145/3281505.3281506 · Cited by 31
“The intensity level was always kept to a limited level following knowledge from related work on EMS [10].”
BackgroundSelf-citationA Minimally Invasive Robotic Tissue Palpation Device
Mir, M., Chen, J., Patel, A., Pinezich, M. R., Guenthart, B. A., Vunjak‐Novakovic, G., & Kim, J.-H. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3357293 · Cited by 28
“Themagnitudesofelectricalvoltageand current(voltage:3.2volts,current:0.5mA)usedinthisstudy, whichcouldalsobeeasilyadjustedtodifferentvalues,were withinasafeandclinicallyrelevantrange(Figs.4,5,6,7,8, and9)[11],[59].”
Interactive Benefits from Switching Electrical to Magnetic Muscle Stimulation
Tanaka, Y., Takahashi, A., & Lopes, P. (2023) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/3586183.3606812 · Cited by 28
“A large portion of safety guidelines of EMS [35] may apply to MMS as both pass electrical currents to muscles (e.g., they both require calibration, etc).”
BackgroundFrom Perception to Action: A Review and Taxonomy on Electrical Muscle Stimulation in HCI
Faltaous, S., Koelle, M., & Schneegaß, S. (2022) · International Conference on Mobile and Ubiquitous Multimedia (MUM) · doi:10.1145/3568444.3568460 · Cited by 26
Fused Spectatorship: Designing Bodily Experiences Where Spectators Become Players
Patibanda, R., Saini, A., Overdevest, N., Montoya, M. F., Li, X., Chen, Y., Nisal, S., Andrés, J., Knibbe, J., van den Hoven, E., et al. (2023) · Proceedings of the ACM on Human-Computer Interaction · doi:10.1145/3611049 · Cited by 26
“To ensure safety, we used a commercial EMS device whose parameters like intensity, pulse rate, and width could not be programmatically controlled, as prior work suggested [52, 54, 62].”
MethodEfthimiou, T. N., Perusquía-Hernández, M., Elsenaar, A., Méhu, M., & Korb, S. (2023) · Behavior Research Methods · doi:10.3758/s13428-023-02262-7 · Cited by 23
“…width, and frequency, as well as electrode area), how much current is injected by a specific NMES procedure, and whether it follows safety guidelines. fNMES is a technique that poses certain risks, as is the case with any technique applying an electrical current to the body (Kono et al., 2018).”
Vanichvoranun, N., Lee, H., Kim, S., & Yoon, S. H. (2024) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3678567 · Cited by 21
“This value is well within the safe range for human interaction, which is less than 1 mA [38].”
Luo, Y., Sun, J., Zeng, Q., Zhang, X., Tan, L., Chen, A., Guo, H., & Wang, X. (2023) · Nano Energy · doi:10.1016/j.nanoen.2023.108425 · Cited by 20
Haeder, S. F., Weimer, D. L., & Mukamel, D. B. (2020) · Journal of Health Politics Policy and Law · doi:10.1215/03616878-8641591 · Cited by 18
Reduction of electrotactile perception threshold using subthreshold vibrotactile stimuli
Ray, R. K., Patel, P., & Manivannan, M. (2021) · Displays · doi:10.1016/j.displa.2021.102056 · Cited by 15
Lopes, P., Chuang, L. L., & Maes, P. (2021) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/3411763.3450407 · Cited by 15
“Some clear examples already exist, such as guidelines that ensure the safe measurement and application of electricity on the human body [10].”
BackgroundNiijima, A., & Kubo, Y. (2023) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3544548.3581192 · Cited by 12
“On the basis of a Japanese Industrial Standards standard (electric therapy apparatus for home use, JIS T 2003:2008) and design guideline [31], we set the maximum intensity of EMS; the pulse width is 200 μs, maximum frequency is 200 Hz, and maximum current is 20 mA.”
MethodShindo, M., Isezaki, T., Koike, Y., & Aoki, R. (2023) · PLoS ONE · doi:10.1371/journal.pone.0285831 · Cited by 12
“Based on the JIS standard (electric therapy apparatus for home use, JIS C 9335–2-209:2018) and the design guidelines [25], we set the pulse width to 200 μ s, the frequency to 200 Hz, and the maximum current to 20 mA. Visual SA group.”
MethodDemonstrating User Authentication via Electrical Muscle Stimulation
Chen, Y., Yang, Z., Abbou, R., Lopes, P., Zhao, B. Y., & Zheng, H. (2021) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/3411763.3451563 · Cited by 11
“Electrode pairs are typically driven using safe and medical compliant muscle stimulators [11].”
BackgroundContactless Electrostatic Piloerection for Haptic Sensations
Iriarte, N., Ezcurdia, I., Elizondo, S., Irisarri, J., Hemmerling, D., Ortiz, A., & Marzo, A. (2023) · IEEE Transactions on Haptics · doi:10.1109/toh.2023.3269885 · Cited by 11
Volunteers’ concerns about facial neuromuscular electrical stimulation
Efthimiou, T. N., Hanel, P. H. P., & Korb, S. (2022) · BMC Psychology · doi:10.1186/s40359-022-00827-3 · Cited by 9
“Indeed, the possibility of inducing injuries with NMES is low, as long as the stimulation parameters are carefully selected [8], the device used complies with the International Electrotechnical Commission guidelines [9], and administrators are trained to follow safety guidelines [10].”
wavEMS: Improving Signal Variation Freedom of Electrical Muscle Stimulation
Kono, M., & Rekimoto, J. (2019) · IEEE Conference on Virtual Reality and 3D User Interfaces (VR) · doi:10.1109/vr.2019.8798102 · Cited by 8
“When experiencing stimulation from EMS systems, it is common to use signals around 1–150 Hz and pulse width with 30–800 μs [12].”
BackgroundMethodSelf-citationPrimed Action: Preserving Agency while Accelerating Reaction Time via Subthreshold Brain Stimulation
Tanaka, Y., Mathews, H. G., & Lopes, P. (2025) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/3746059.3747634 · Cited by 7
“Since TMS [57] and EMS [33] could interfere with implanted devices (e.g., pacemakers), we did not recruit such participants.”
Shi, Y., Peng, T., Liang, Y., Li, Y., Ren, R., Zhang, Y., Yan, X., Chen, X., Chen, D., & Shen, G. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c13002 · Cited by 6
Transcutaneous Electrical Stimulation for Haptics: A Narrative Review
Ota, T., & Aoyama, K. (2025) · IEEE World Haptics Conference (WHC) · doi:10.1109/whc64065.2025.11123204 · Cited by 6
“The safety guideline of TENS is studied [137], and it has become widely known among researchers.”
Xu, M., Zhu, Y., Chen, Z., Fu, Y., Zhu, Z., Fan, T., Tang, Z., Li, Y., & Fu, S. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c20611 · Cited by 6
Ohara, H., & Hasegawa, S. (2022) · Augmented Humans International Conference (AHs) · doi:10.1145/3519391.3519415 · Cited by 6
“This is why many researchers have used EMS to study HCI and VR in the past decade [17].”
BackgroundSelf-powered biomedical devices: biology, materials, and their interfaces
Zhuang, Y., Zhang, Q., Wan, Z., Geng, H., Xue, Z., & Cao, H. (2025) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/adaff2 · Cited by 6
Self-powered electro-tactile system for virtual tactile experiences
Shi, Y., Chen, X., & Wang, Z. L. (2022) · IEEE International Flexible Electronics Technology Conference (IFETC) · doi:10.1109/ifetc53656.2022.9948520 · Cited by 6
Myo Action: Accelerating Voluntary Actions via Electromyography and Muscle Stimulation
Tanaka, Y., Hsu, C., Felalaga, B., & Lopes, P. (2026) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3772318.3791103 · Cited by 5
“Our medical-grade stimulator controls electrical currents independent of skin-impedance, and our software limits the maximum output to 20 mA—25 times below the safety limit [27].”
Bioimpedance measurements of fibrotic and acutely injured lung tissues
Mir, M., Chen, J., Patel, A., Pinezich, M. R., Hudock, M. R., Yoon, A., Diane, M., O’Neill, J. D., Bacchetta, M. D., Vunjak‐Novakovic, G., et al. (2025) · Acta Biomaterialia · doi:10.1016/j.actbio.2025.01.039 · Cited by 5
In-body current path manipulation with minimal attenuation
Kang, D., Park, B., Hwang, J., Kim, Y., Kim, S.-H., Kim, H. W., Yu, K. J., Jeon, J., Lee, H. Y., Chung, Y., et al. (2025) · Science Advances · doi:10.1126/sciadv.adx5922 · Cited by 6
Force Control on Fingertip Using EMS to Maintain Light Touch
Shindo, M., Isezaki, T., Aoki, R., & Koike, Y. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630237 · Cited by 5
“Based on the JIS standard (electric therapy apparatus for home use, JIS C 9335-2-209: 2018) and the design guideline [11], we set the maximum pulse width to 100 s, the maximum frequency to 200 Hz, and the maximum current to 20 mA.”
MethodEMS-Supported Throwing: Preliminary Investigation on EMS-Supported Training of Movement Form
Niwa, R., Izumi, K., Suzuki, S., & Ochiai, Y. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-05028-2_31 · Cited by 5
Mishra, A., Kumar, P., Shukla, J., & Parnami, A. (2022) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3550310 · Cited by 4
“5 milliamperes as per the human electrical safety design guidelines given in [15], putting it within a safe operating range.”
Influence of Electrical Stimulation Intensity on the Perception of Piquancy
Ohno, M., Aoyama, K., Amemiya, T., Kuzuoka, H., Matsumoto, K., & Narumi, T. (2023) · IEEE World Haptics Conference (WHC) · doi:10.1109/whc56415.2023.10224409 · Cited by 4
“Moreover, for safety reasons, the range of the enhancement effect remains limited because the amount of electrical stimulation is limited [32], [33].”
BackgroundShindo, M., Isezaki, T., & Aoki, R. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10340950 · Cited by 4
“Using the JIS standard (electric therapy apparatus for home use, JIS C 9335-2-209:2018) and the design guidelines [15] as a basis, we set the pulse width to 200 µs, frequency to 200 Hz, and maximum current to 20 mA.”
MethodDanry, V., Chicos, L., Fonseca, M., Ishraki, K., & Maes, P. (2024) · Augmented Humans International Conference (AHs) · doi:10.1145/3652920.3652932 · Cited by 4
“For precautions for tACS see [17].”
BackgroundPower-on-Touch: Powering Actuators, Sensors, and Devices during Interaction
Mazursky, A., Gupta, A., de la Cruz, A., & Lopes, P. (2025) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3706598.3713987 · Cited by 4
“We see no reason why they cannot be improved, thus we bumped it up in our rating. mA [27]).”
Yang, X., Sayono, J., Xu, J., & Zhang, Y. (2024) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/3613905.3650769 · Cited by 3
“Prior work has outlined the safety regulations for applying electricity on the human body [16, 27, 45] under international guidelines [33].”
Grand Challenges around Designing Computers’ Control Over Our Bodies
Mueller, F., Bianchi‐Berthouze, N., Sra, M., Gonzalez-Franco, M., Pohl, H., Boll, S., Byrne, R., Caetano, A., İnami, M., Knibbe, J., et al. (2026) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3772318.3790606 · Cited by 3
“Clear guidance and training for users are also essential for safe and effective operation [78, 121].”
Grutio: System for Reproducing Swallowing Sensation Using Neck-Skin Movement
Mizoguchi, I., Sakurai, S., Hirota, K., & Nojima, T. (2021) · IEEE Access · doi:10.1109/access.2021.3098228 · Cited by 3
Evaluation of Electric Muscle Stimulation Method for Haptic Augmented Reality
Ishimaru, T., & Saga, S. (2023) · Sensors · doi:10.3390/s23041796 · Cited by 2
“We created these with safety in mind, referring to the study of design guidelines [26].”
MethodPiano Instruction Using AR Hand Presentation and Hand Synchronization by EMS
Mori, S., Ihara, K., & Kawaguchi, I. (2024) · Australian Conference on Human-Computer Interaction (OzCHI) · doi:10.1145/3726986.3727029 · Cited by 2
“The safety of such EMS stimulation has been confirmed by the guidelines proposed for research purposes [11, 12, 36].”
TingleTouch: Touch Guidance through Electrical Stimulation in Resistance Training
Kim, D.-U., Jo, H., Kim, H., Suzuki, R., Je, S., & Kim, Y. (2026) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3772318.3791646 · Cited by 2
“Kono et al. [35] outlined safety guidelines for EMS that describe how current, frequency, electrode placement, and body impedance affect user safety.”
The Do-It-Yourself Electrocardiogram
Haase, E., O’Hara, R., & Maybhate, A. (2022) · Biomedical Engineering Education · doi:10.1007/s43683-021-00061-0 · Cited by 2
Efthimiou, T. N., Perusquía-Hernández, M., Elsenaar, A., Méhu, M., & Korb, S. (2022) · PsyArXiv (OSF Preprints) · doi:10.31234/osf.io/fd8ce · Cited by 2
Leppämäki, M. (2024) · Theseus (Ammattikorkeakoulujen) · Cited by 2
Yamaguchi, T., Tsukahara, A., Tanaka, Y., & Ueno, A. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3541655 · Cited by 1
“Restrictions apply.”
How to Design, Build, and Use Interactive Electrical Stimulation
Tanaka, Y., & Lopes, P. (2025) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/3706599.3706647 · Cited by 1
“Importantly, we detail the necessary safety measured implemented on the stimulator [6] and that participants should apply on their future research.”
Ciarrocchi, D., den Eeckhoudt, R. V., Rusli, N. I., Zompanti, A., Grasso, S., di Biase, L., Santonico, M., Pennazza, G., & Taurino, I. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1717650 · Cited by 1
“The applied current of 5 μ A correspond to a current density of 140 μ A/cm 2 , adhering to the applicable safety current standards for patients (0.5 mA/cm 2 ) (Kono et al., 2018).”
InfluentialPrivacy & Safety Challenges of On-Body Interaction Techniques
Gerhardt, D., Bhardwaj, D., Ram, A., Zenner, A., Steimle, J., & Krombholz, K. (2026) · International Conference on Human Factors in Computing Systems · doi:10.1145/3772318.3790403 · Cited by 2
“Drawing on established safety standards for electrical stimulation [27] and risk mitigation strategies for autonomous haptics [40], this guideline mandates strict hardware limits and robust fail-safe mechanisms to prevent injury.”
Demonstrating Haptic Source-Effector: Full-Body Haptics via Non-Invasive Brain Stimulation
Tanaka, Y., Mathews, H. G., Serfaty, J., & Lopes, P. (2024) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/3672539.3686756 · Cited by 1
“The safety protocol for TMS largely overlaps with EMS’ [3], as both apply electrical currents (e.g., they both require per-user calibration, etc).”
Efthimiou, T. N. (2024) · Open Access at Essex (University of Essex) · Cited by 1
Artificial muscle memory : facilitating motor learning by wearable soft exoskeletons
後藤, 貴., & Kunze, K. S. (2018) · Institutional Repositories DataBase (IRDB)
Volunteers’ concerns about facial neuromuscular electrical stimulationPreprint
Efthimiou, T. N., Hanel, P. H. P., & Korb, S. (2022) · PsyArXiv (OSF Preprints) · doi:10.31234/osf.io/ks4de
Smart Wellness Wearable Devices
Wei, D., & Chen, L. (2022) · Advances in Social Science, Education and Humanities Research/Advances in social science, education and humanities research · doi:10.2991/assehr.k.220706.075
Shindo, M., & Aoki, R. (2024) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc54092.2024.10831074
“Using the JIS standard (electric therapy apparatus for home use, JIS C 9335-2-209:2018) and the design guidelines [15] as a basis, the pulse width was set to 200 µs, maximum frequency to 200 Hz, and maximum current to 20 mA.”
Additional file 1 of Volunteers’ concerns about facial neuromuscular electrical stimulation
Efthimiou, T. N., Hanel, P. H., & Korb, S. (2022) · Figshare · doi:10.6084/m9.figshare.19728616
Takahashi, A. (2022) · Institutional Repositories DataBase (IRDB) · doi:10.18952/00010096
Demonstrating Myo Action: Accelerating Voluntary Actions via Electromyography and Muscle Stimulation
Tanaka, Y., Hsu, C., Felalaga, B., & Lopes, P. (2026) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/3772363.3799165
“Our medical-grade stimulator controls electrical currents independent of skin-impedance, and our software limits the maximum output to 20 mA—25 times below the safety limit [10].”
BladderSense: A Wearable Ultrasound System for Continuous Bladder Monitoring in Real-World Use
Chen, K., Toro, U. S., Lin, J., Huang, C., Xiang, J., Wang, L., Cui, H., Zhu, L., & Wu, K. (2026) · International Conference on Mobile Systems, Applications, and Services · doi:10.1145/3745756.3809187
“BladderSense employs an ultrasonic excitation voltage of 30 V, below the human safety limit for continuous contact of 50 V [61].”
Grand Challenges around Designing Computers’ Control Over Our Bodies
Mueller, F., Bianchi‐Berthouze, N., Sra, M., Gonzalez-Franco, M., Pohl, H., Boll, S., Byrne, R., Caetano, A., Inami, M., Knibbe, J., et al. (2026) · Apollo (University of Cambridge) · doi:10.17863/cam.130555
Litsas, P. (2026) · DSpace - NTUA (National Technical University of Athens) · doi:10.26240/heal.ntua.32779
Kim, J., Kim, K. K., Rhee, T. J., Rhee, T. J., & Jung, M. (2026) · Journal of the Korea Computer Graphics Society · doi:10.15701/kcgs.2026.32.3.23
Shindo, M., Aoki, R., & Hasegawa, N. (2026) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-026-02114-3
When the body is moved: playfulness under invisible control
Patibanda, R., van den Hoven, E., & Mueller, F. (2026) · Humanities and Social Sciences Communications · doi:10.1057/s41599-026-08167-y
Shi, Y., Feng, C., Xu, Z., Liang, Y., Liu, X., Yuan, X., Luo, J., Zhang, J., Qin, Y., & Shen, G. (2026) · Advanced Functional Materials · doi:10.1002/adfm.79266
Metadata
- Authors
- Kono, M., Takahashi, T., Nakamura, H., Miyaki, T., & Rekimoto, J.
- Affiliations
- The University of Tokyo (JP)
- Japan Society for the Promotion of Science (JP)
- Sony Computer Science Laboratories (JP)
- Venue
- ACM Transactions on Computer-Human Interaction
- Published
- 2018-06-08
- Volume
- 25
- Issue
- 3
- Pages
- 1-36
- ISSN
- 1073-0516 (ISSN-L)
- 1557-7325
- OpenAlex
- W2808446212
- Cited by
- 63
- References
- 190
- Citations by year
- 2026: 7 · 2025: 9 · 2024: 9 · 2023: 11 · 2022: 12 · 2021: 9 · 2020: 1 · 2019: 3 · 2018: 2
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- ACM Transactions on Computer-Human Interaction (publishedVersion)
- Funders
- JSPS KAKENHI (15J03919 and 14J09902)
- Topics
- Physical Sciences › Computer Science › Human-Computer Interaction › Innovative Human-Technology Interaction
- Physical Sciences › Computer Science › Human-Computer Interaction › Interactive and Immersive Displays
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Keywords
- electrical safety, bioelectricity, human-computer interaction, electric field sensing, muscle stimulation, design guidelines, human-robot interaction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.