Biological Insight from Super-Resolution Microscopy: What We Can Learn from Localization-Based Images
Open accessThe DOI matches its Crossref record; 103 of the 103 references it cites were found in a registry or an index.
Abstract
Super-resolution optical imaging based on the switching and localization of individual fluorescent molecules [photoactivated localization microscopy (PALM), stochastic optical reconstruction microscopy (STORM), etc.] has evolved remarkably over the last decade. Originally driven by pushing technological limits, it has become a tool of biological discovery. The initial demand for impressive pictures showing well-studied biological structures has been replaced by a need for quantitative, reliable data providing dependable evidence for specific unresolved biological hypotheses. In this review, we highlight applications that showcase this development, identify the features that led to their success, and discuss remaining challenges and difficulties. In this context, we consider the complex topic of defining resolution for this imaging modality and address some of the more common analytical methods used with this data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1967) · Cited by 23,719
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
DBSCAN Revisited, Revisited: Why and How You Should (Still) Use DBSCAN
Schubert, E., Sander, J., Ester, M., Kriegel, H. P., & Xu, X. (2017) · ACM Transactions on Database Systems · doi:10.1145/3068335 · Cited by 2,737
Beiträge zur Theorie des Mikroskops und der mikroskopischen Wahrnehmung
Abbe, E. (1873) · Archiv für Mikroskopische Anatomie · doi:10.1007/bf02956173 · Cited by 2,724
HaloTag: A Novel Protein Labeling Technology for Cell Imaging and Protein Analysis
Los, G. V., Encell, L. P., McDougall, M. G., Hartzell, D. D., Karassina, N., Zimprich, C., Wood, M. G., Learish, R., Ohana, R. F., Urh, M., et al. (2008) · ACS Chemical Biology · doi:10.1021/cb800025k · Cited by 2,624
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
A practical guide to evaluating colocalization in biological microscopy
Dunn, K. W., Kamocka, M. M., & McDonald, J. H. (2011) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00462.2010 · Cited by 2,038
Cited by
Super-resolution microscopy demystified
Schermelleh, L., Ferrand, A., Huser, T., Eggeling, C., Sauer, M., Biehlmaier, O., & Drummen, G. P. C. (2019) · Nature Cell Biology · doi:10.1038/s41556-018-0251-8 · Cited by 1,211
Sage, D., Pham, T.-A., Babcock, H., Lukes, T., Pengo, T., Chao, J., Velmurugan, R., Herbert, A., Agrawal, A., Colabrese, S., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0364-4 · Cited by 333
Switchable Fluorophores for Single-Molecule Localization Microscopy
Li, H., & Vaughan, J. C. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00767 · Cited by 319
Khater, I. M., Nabi, I. R., & Hamarneh, G. (2020) · Patterns · doi:10.1016/j.patter.2020.100038 · Cited by 286
Zwettler, F. U., Reinhard, S., Gambarotto, D., Bell, T. D. M., Hamel, V., Guichard, P., & Sauer, M. (2020) · Nature Communications · doi:10.1038/s41467-020-17086-8 · Cited by 189
The cell biologist's guide to super-resolution microscopy
Jacquemet, G., Carisey, A. F., Hamidi, H., Henriques, R., & Leterrier, C. (2020) · Journal of Cell Science · doi:10.1242/jcs.240713 · Cited by 171
“A processing software is then used to fit the blinking events and create a super-resolved image (Baddeley and Bewersdorf, 2018).”
MethodA practical guide to optimization in X10 expansion microscopy
Truckenbrodt, S., Sommer, C., Rizzoli, S. O., & Danzl, J. G. (2019) · Nature Protocols · doi:10.1038/s41596-018-0117-3 · Cited by 159
Imaging Approaches for the Study of Metabolism in Real Time Using Genetically Encoded Reporters
Chandris, P., Giannouli, C. C., & Panayotou, G. (2022) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2021.725114 · Cited by 19
“Collectively, although super resolution has a constantly expanding irrefutable role in our understanding of how cells organize their subcellular entities (Baddeley and Bewersdorf, 2018), its role in dissecting highly dynamic phenomena in living systems is rather limited so far due to the increased phototoxicity by hig…”
Background
Metadata
- Authors
- Baddeley, D., & Bewersdorf, J.
- Venue
- Annual Review of Biochemistry
- Publisher
- Annual Reviews
- Published
- 2018-06-20
- Volume
- 87
- Issue
- 1
- Pages
- 965-989
- ISSN
- 0066-4154 (ISSN-L)
- 1545-4509
- OpenAlex
- W2779346725
- Cited by
- 186
- References
- 103
- FWCI
- 1.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.