Microfluidics and Coagulation Biology
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The study of blood ex vivo can occur in closed or open systems, with or without flow. Microfluidic devices, which constrain fluids to a small (typically submillimeter) scale, facilitate analysis of platelet function, coagulation biology, cellular biorheology, adhesion dynamics, and pharmacology and, as a result, can be an invaluable tool for clinical diagnostics. An experimental session can accommodate hundreds to thousands of unique clotting, or thrombotic, events. Using microfluidics, thrombotic events can be studied on defined surfaces of biopolymers, matrix proteins, and tissue factor, under constant flow rate or constant pressure drop conditions. Distinct shear rates can be generated on a device using a single perfusion pump. Microfluidics facilitated both the determination of intraluminal thrombus permeability and the discovery that platelet contractility can be activated by a sudden decrease in flow. Microfluidic devices are ideal for multicolor imaging of platelets, fibrin, and phosphatidylserine and provide a human blood analog to mouse injury models. Overall, microfluidic advances offer many opportunities for research, drug testing under relevant hemodynamic conditions, and clinical diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tsai, M., Kita, A., Leach, J., Rounsevell, R., Huang, J. N., Moake, J., Ware, R. E., Fletcher, D. A., & Lam, W. A. (2012) · Journal of Clinical Investigation · doi:10.1172/jci58753 · Cited by 297 · cited 1×
“(27) have had success culturing endothelial cells on fibronectincoated surfaces in microfluidic chambers (Figure 3g).”
Background
Cited by
Bioprinted thrombosis-on-a-chip
Zhang, Y. S., Davoudi, F., Walch, P., Manbachi, A., Luo, X., Dell'Erba, V., Miri, A. K., Albadawi, H., Arneri, A., Li, X., et al. (2016) · Lab on a Chip · doi:10.1039/c6lc00380j · Cited by 227
Assessment of whole blood thrombosis in a microfluidic device lined by fixed human endothelium
Jain, A., van der Meer, A. D., Papa, A.-L., Barrile, R., Lai, A., Schlechter, B. L., Otieno, M. A., Louden, C. S., Hamilton, G. A., Michelson, A. D., et al. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0095-6 · Cited by 148
New microfluidic paths to test for bleeding or clotting
Diamond, S. L. (2017) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-017-0476-9 · Cited by 9
Self-citation
Metadata
- Authors
- Colace, T. V., Tormoen, G. W., McCarty, O. J. T., & Diamond, S. L.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2013-07-11
- Volume
- 15
- Issue
- 1
- Pages
- 283-303
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2151132808
- Cited by
- 124
- References
- 1
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfluidics and Coagulation Biology. https://app.cochat.ai/papers/10.1146/annurev-bioeng-071812-152406
- The paper
- Colace, T. V., Tormoen, G. W., McCarty, O. J. T., & Diamond, S. L. (2013). Microfluidics and Coagulation Biology. Annual Review of Biomedical Engineering. https://doi.org/10.1146/annurev-bioeng-071812-152406
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.