CoChat

MRI-Guided Nanorobotic Systems for Therapeutic and Diagnostic Applications

Vartholomeos, Panagiotis, Fruchard, Matthieu, Ferreira, Antoine, Mavroidis, Constantinos · 2011 · Annual Review of Biomedical Engineering
Cited by 118

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

This review presents the state of the art of magnetic resonance imaging (MRI)-guided nanorobotic systems that can perform diagnostic, curative, and reconstructive treatments in the human body at the cellular and subcellular levels in a controllable manner. The concept of an MRI-guided nanorobotic system is based on the use of an MRI scanner to induce the required external driving forces to propel magnetic nanocapsules to a specific target. It is an active targeting mechanism that provides simultaneous propulsion and imaging capabilities, which allow the implementation of real-time feedback control of the targeting process. The architecture of the system comprises four main modules: (a) the nanocapsules, (b) the MRI propulsion module, (c) the MRI tracking module (for image processing), and (d) the controller module. A key concept is the nanocapsule technology, which is based on carriers such as liposomes, polymer micelles, gold nanoparticles, quantum dots, metallic nanoshells, and carbon nanotubes. Descriptions of the significant challenges faced by the MRI-guided nanorobotic system are presented, and promising solutions proposed by the involved research community are discussed. Emphasis is placed on reviewing the limitations imposed by the scaling effects that dominate within the blood vessels and also on reviewing the control algorithms and computational tools that have been developed for real-time propulsion and tracking of the nanocapsules.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1146/annurev-bioeng-071910-124724

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 118

Metadata

Authors
Vartholomeos, P., Fruchard, M., Ferreira, A., & Mavroidis, C.
Venue
Annual Review of Biomedical Engineering
Published
2011-08-15
Volume
13
Issue
1
Pages
157-184
ISSN
  • 1523-9829 (ISSN-L)
  • 1545-4274
OpenAlex
W2149587958
Cited by
118
References
3
FWCI
0.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MRI-Guided Nanorobotic Systems for Therapeutic and Diagnostic Applications. https://app.cochat.ai/papers/10.1146/annurev-bioeng-071910-124724
The paper
Vartholomeos, P., Fruchard, M., Ferreira, A., & Mavroidis, C. (2011). MRI-Guided Nanorobotic Systems for Therapeutic and Diagnostic Applications. Annual Review of Biomedical Engineering. https://doi.org/10.1146/annurev-bioeng-071910-124724

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.