Super-Resolution Microscopy for Structural Cell Biology
The DOI matches its Crossref record; 145 of the 145 references it cites were found in a registry or an index.
Abstract
Super-resolution microscopy techniques, and specifically single-molecule localization microscopy (SMLM), are approaching nanometer resolution inside cells and thus have great potential to complement structural biology techniques such as electron microscopy for structural cell biology. In this review, we introduce the different flavors of super-resolution microscopy, with a special emphasis on SMLM and MINFLUX (minimal photon flux). We summarize recent technical developments that pushed these localization-based techniques to structural scales and review the experimental conditions that are key to obtaining data of the highest quality. Furthermore, we give an overview of different analysis methods and highlight studies that used SMLM to gain structural insights into biologically relevant molecular machines. Ultimately, we give our perspective on what is needed to push the resolution of these techniques even further and to apply them to investigating dynamic structural rearrangements in living cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
cryoSPARC: algorithms for rapid unsupervised cryo-EM structure determination
Punjani, A., Rubinstein, J. L., Fleet, D. J., & Brubaker, M. A. (2017) · Nature Methods · doi:10.1038/nmeth.4169 · Cited by 11,626
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Three-Dimensional Super-Resolution Imaging by Stochastic Optical Reconstruction Microscopy
Huang, B., Wang, W., Bates, M., & Zhuang, X. (2008) · Science · doi:10.1126/science.1153529 · Cited by 2,796
HaloTag: A Novel Protein Labeling Technology for Cell Imaging and Protein Analysis
Los, G. V., Encell, L. P., McDougall, M. G., Hartzell, D. D., Karassina, N., Zimprich, C., Wood, M. G., Learish, R., Ohana, R. F., Urh, M., et al. (2008) · ACS Chemical Biology · doi:10.1021/cb800025k · Cited by 2,624
A general method for the covalent labeling of fusion proteins with small molecules in vivo
Keppler, A., Gendreizig, S., Gronemeyer, T., Pick, H., Vogel, H., & Johnsson, K. (2003) · Nature Biotechnology · doi:10.1038/nbt765 · Cited by 1,956
Subdiffraction‐Resolution Fluorescence Imaging with Conventional Fluorescent Probes
Heilemann, M., van de Linde, S., Schüttpelz, M., Kasper, R., Seefeldt, B., Mukherjee, A., Tinnefeld, P., & Sauer, M. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200802376 · Cited by 1,866
Nanoscale architecture of integrin-based cell adhesions
Kanchanawong, P., Shtengel, G., Pasapera, A. M., Ramko, E. B., Davidson, M. W., Hess, H. F., & Waterman, C. M. (2010) · Nature · doi:10.1038/nature09621 · Cited by 1,567
Multicolor Super-Resolution Imaging with Photo-Switchable Fluorescent Probes
Bates, M., Huang, B., Dempsey, G. T., & Zhuang, X. (2007) · Science · doi:10.1126/science.1146598 · Cited by 1,504
Cited by
Mechanisms of microtubule organization in differentiated animal cells
Akhmanova, A., & Kapitein, L. C. (2022) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-022-00473-y · Cited by 233
One-step nanoscale expansion microscopy reveals individual protein shapes
Shaib, A. H., Chouaib, A. A., Chowdhury, R., Altendorf, J., Mihaylov, D., Zhang, C., Krah, D., Imani, V., Spencer, R. K. W., Georgiev, S. V., et al. (2025) · Nature Biotechnology · doi:10.1038/s41587-024-02431-9 · Cited by 104
Visualizing proteins by expansion microscopy
(2022) · doi:10.1101/2022.08.03.502284 · Cited by 104
Advancing membrane-associated protein docking with improved sampling and scoring in Rosetta
Samnata, R., Harmalkar, A., Prathima, P., & Gray, J. J. (2024) · doi:10.1101/2024.07.09.602802 · Cited by 5
“11,12 Conversely, membrane-mimetic platforms molecular resolution but do not replicate the native cell environment 13,14 .”
Advancing Membrane-Associated Protein Docking with Improved Sampling and Scoring in Rosetta
(2024) · doi:10.1021/acs.jctc.4c00927 · Cited by 5
Metadata
- Authors
- Liu, S., Hoess, P., & Ries, J.
- Venue
- Annual Review of Biophysics
- Publisher
- Annual Reviews
- Published
- 2022-05-09
- Volume
- 51
- Issue
- 1
- Pages
- 301-326
- ISSN
- 1936-122X (ISSN-L)
- 1936-1238
- OpenAlex
- W4210283200
- Cited by
- 220
- References
- 145
- FWCI
- 5.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.