Mass Spectrometry for Rapid Characterization of Microorganisms
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Advances in instrumentation, proteomics, and bioinformatics have contributed to the successful applications of mass spectrometry (MS) for detection, identification, and classification of microorganisms. These MS applications are based on the detection of organism-specific biomarker molecules, which allow differentiation between organisms to be made. Intact proteins, their proteolytic peptides, and nonribosomal peptides have been successfully utilized as biomarkers. Sequence-specific fragments for biomarkers are generated by tandem MS of intact proteins or proteolytic peptides, obtained after, for instance, microwave-assisted acid hydrolysis. In combination with proteome database searching, individual biomarker proteins are unambiguously identified from their tandem mass spectra, and from there the source microorganism is also identified. Such top-down or bottom-up proteomics approaches permit rapid, sensitive, and confident characterization of individual microorganisms in mixtures and are reviewed here. Examples of MS-based functional assays for detection of targeted microorganisms, e.g., Bacillus anthracis, in environmental or clinically relevant backgrounds are also reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Characterization of intact microorganisms by MALDI mass spectrometry
Fenselau, C., & Demirev, P. A. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10004 · Cited by 834
Self-citationMALDI‐TOF mass spectrometry of bacteria*
Lay, J. O. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10003 · Cited by 507
Identification of bacteria using mass spectrometry
Anhalt, J. P., & Fenselau, C. (1975) · Analytical Chemistry · doi:10.1021/ac60352a007 · Cited by 504
Self-citationAn accurate mass tag strategy for quantitative and high-throughput proteome measurements
Smith, R. D., Anderson, G. A., Lipton, M. S., Pasa-Tolic, L., Shen, Y., Conrads, T. P., Veenstra, T. D., & Udseth, H. R. (2002) · PROTEOMICS · doi:10.1002/1615-9861(200205)2:5<513::aid-prot513>3.0.co;2-w · Cited by 432
COMPARATIVE DNA ANALYSIS ACROSS DIVERSE GENOMES
Karlin, S., Campbell, A. M., & Mrázek, J. (1998) · Annual Review of Genetics · doi:10.1146/annurev.genet.32.1.185 · Cited by 362
Microorganism Identification by Mass Spectrometry and Protein Database Searches
Demirev, P. A., Ho, Y.-P., Ryzhov, V., & Fenselau, C. (1999) · Analytical Chemistry · doi:10.1021/ac990165u · Cited by 326
Self-citationCarbonnelle, E., Beretti, J.-L., Cottyn, S., Quesne, G., Berche, P., Nassif, X., & Ferroni, A. (2007) · Journal of Clinical Microbiology · doi:10.1128/jcm.02405-06 · Cited by 242
Valentine, N., Wunschel, S., Wunschel, D., Petersen, C., & Wahl, K. (2005) · Applied and Environmental Microbiology · doi:10.1128/aem.71.1.58-64.2005 · Cited by 231
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry in clinical chemistry
Marvin, L. F., Roberts, M. A., & Fay, L. B. (2003) · Clinica Chimica Acta · doi:10.1016/j.cccn.2003.08.008 · Cited by 226
Cited by
Primary biological aerosol particles in the atmosphere: a review
Després, V. R., Huffman, J. A., Burrows, S. M., Hoose, C., Safatov, A. S., Buryak, G., Fröhlich-Nowoisky, J., Elbert, W., Andreae, M. O., Pöschl, U., et al. (2012) · Tellus B: Chemical and Physical Meteorology · doi:10.3402/tellusb.v64i0.15598 · Cited by 1,500
“…range of instrumental and bioanalytical techniques such as chromatography coupled to mass spectrometry, spectrophotometry, fluorescence spectroscopy, immunoassays, dye assays, etc. (Griffith and DeCosemo, 1994; Reponen et al., 1995; Franze et al., 2005; Pöschl, 2005; Demirev and Fenselau, 2008).”
MethodBiosensors for detection of pathogenic bacteria
Ivnitski, D., Abdel-Hamid, I., Atanasov, P., & Wilkins, E. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00039-1 · Cited by 931
Environmental Mass Spectrometry: Emerging Contaminants and Current Issues
Richardson, S. D. (2010) · Analytical Chemistry · doi:10.1021/ac101102d · Cited by 634
Diehn, S., Zimmermann, B., Bağcıoğlu, M., Seifert, S., Kohler, A., Ohlson, M., Fjellheim, S., Weidner, S., & Kneipp, J. (2018) · Scientific Reports · doi:10.1038/s41598-018-34800-1 · Cited by 356
MALDI TOF MS profiling of bacteria at the strain level: A review
Sandrin, T. R., Goldstein, J. E., & Schumaker, S. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21359 · Cited by 334
Barbuddhe, S. B., Maier, T., Schwarz, G., Kostrzewa, M., Hof, H., Domann, E., Chakraborty, T., & Hain, T. (2008) · Applied and Environmental Microbiology · doi:10.1128/aem.02689-07 · Cited by 323
Rapid Identification of Bacteria with a Disposable Colorimetric Sensing Array
Carey, J. R., Suslick, K. S., Hulkower, K. I., Imlay, J. A., Imlay, K. R. C., Ingison, C. K., Ponder, J. B., Sen, A., & Wittrig, A. E. (2011) · Journal of the American Chemical Society · doi:10.1021/ja201634d · Cited by 273
EDWARDS-JONES, V., CLAYDON, M. A., EVASON, D. J., WALKER, J., FOX, A. J., & GORDON, D. B. (2000) · Journal of Medical Microbiology · doi:10.1099/0022-1317-49-3-295 · Cited by 253
MS/MS networking guided analysis of molecule and gene cluster families
Nguyen, D. D., Wu, C.-H., Moree, W. J., Lamsa, A., Medema, M. H., Zhao, X., Gavilan, R. G., Aparicio, M., Atencio, L., Jackson, C., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1303471110 · Cited by 249
Angeletti, S. (2017) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2016.09.003 · Cited by 247
“In the following years, the technique was successfully applied and described as a simple and rapid method to identify whole cells of bacterial and fungal microorganisms (Lay JO, 2001; Keys et al. 2004; Demirev and Fenselau, 2008), but despite this, it was slowly applied to clinical microbiology.”
BackgroundMethodGiebel, R., Worden, C., Rust, S. M., Kleinheinz, G. T., Robbins, M., & Sandrin, T. R. (2010) · Advances in Applied Microbiology · doi:10.1016/s0065-2164(10)71006-6 · Cited by 176
Proteomics for routine identification of microorganisms
Welker, M. (2011) · PROTEOMICS · doi:10.1002/pmic.201100049 · Cited by 175
“The first studies on ICMS already indicated the potential for rapid microbial identification [31].”
Background
Metadata
- Authors
- Demirev, P. A., & Fenselau, C.
- Venue
- Annual Review of Analytical Chemistry
- Publisher
- Annual Reviews
- Published
- 2008-07-01
- Volume
- 1
- Issue
- 1
- Pages
- 71-93
- ISSN
- 1936-1327 (ISSN-L)
- 1936-1335
- OpenAlex
- W2120953279
- Cited by
- 213
- References
- 48
- FWCI
- 0.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.