Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 931

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Biosensors for detection of pathogenic bacteria

Ivnitski, Dmitri, Abdel-Hamid, Ihab, Atanasov, Plamen, Wilkins, Ebtisam·1999·Biosensors and Bioelectronics

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0956-5663(99)00039-1

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 228

  1. Abdel-Hamid, 1998, Fast amperometrci assay for E. coli O157:H7 using partially immeresed immunoelectrodes, Electronalysis, 10, 758, 10.1002/(SICI)1521-4109(199809)10:11<758::AID-ELAN758>3.0.CO;2-5 · doi:10.1002/(sici)1521-4109(199809)10:11<758::aid-elan758>3.0.co;2-5
  2. Abdel-Hamid, 1998, Development of a flow-through immunoassay system, Sensors Actuators B, 49, 202, 10.1016/S0925-4005(98)00125-7 · doi:10.1016/s0925-4005(98)00125-7
  3. Abdel-Hamid, 1999, Flow-through immunofiltration assay system for rapid detection of E. coli O157:H7, Biosensors Bioelectronics, 14, 309, 10.1016/S0956-5663(99)00004-4 · DOI · Paper page
  4. Abdel-Hamid, I., Ivnitski, D., Atanasov, P., Wilkins, E., 1999. Flow-injection immunosensor and immunofiltration assay system for rapid detection of bacteria. Anal. Chim. Acta in press. · doi:10.1016/s0003-2670(99)00580-2
  5. Allman, R., Manchee, R., Lloyd, D., 1993. Flow cytometric analysis of heterogeneous bacterial populations. In: Lloyd, D. (Ed.), Flow Cytometry in Microbiology. Springer-Verlag London Limited, Germany, pp. 27–47 (Chapter 3). · DOI
  6. Alvarez-Icaza, 1993, Mass production of biosensors, Anal. Chem., 65, 525A, 10.1021/ac00059a001 · doi:10.1021/ac00059a001
  7. Andle, 1992, An acoustic plate mode biosensor, Sensors Actuators B, 8, 191, 10.1016/0925-4005(92)80180-6 · doi:10.1016/0925-4005(92)80180-6
  8. Aubert, 1997, Accelerated detection of DNA on Membranes by automated enzyme-linked immunofiltration assay, Anal. Biochem., 247, 25, 10.1006/abio.1997.2030 · DOI
  9. Avanissaghajani, 1996, Molecular technique for rapid identification of mycobacteria, J. Clin. Microbiol., 34, 98, 10.1128/JCM.34.1.98-102.1996 · doi:10.1128/jcm.34.1.98-102.1996
  10. Bao, 1996, Determination of microorganisms with a quartz crystal microbalance sensor, Anal. Chim. Acta, 319, 97, 10.1016/0003-2670(95)00466-1 · doi:10.1016/0003-2670(95)00466-1
  11. Basile, 1998, Pathogenic Bacteria: their detection and differentiation by rapid lipid profiling with pyrolysis mass-spectrometry, Trends Anal. Chem., 17, 95, 10.1016/S0165-9936(97)00103-9 · doi:10.1016/s0165-9936(97)00103-9
  12. Bataillard, 1988, Direct detection of immunospecies by capacitance measurements, Anal. Chem., 60, 2374, 10.1021/ac00172a011 · doi:10.1021/ac00172a011
  13. Ben-Dov, 1997, Piezoelectric immunosensors for urine specimens of Chlamydia-Trachomatis emploting quartz-crystal microbalance microgravimetric analyses, Anal. Chem., 69, 3506, 10.1021/ac970216s · doi:10.1021/ac970216s
  14. Beran, 1991, Food safety: an overview of problems, Dairy Food Environ. Sanit., 11, 189
  15. Bird, J.A., Easter, M.C., Hadfield, S.G., May, E., Stringer, M.F., 1989. Rapid Salmonella detection by a combination of conductance and immunological techniques. In: Standard, C.J., Petit, S.B., Skinner, F.A. (Eds.), Rapid Microbiological Methods for Foods, Beverages and Pharmaceuticals. Soc. Appl. Bacteriology Tech. Series, No 25. Blackwell Sci. Publications, Oxford, pp. 165–183.
  16. Blasco, 1998, Specific assays for bacteria using phage mediated release of adenylate kinase, J. Appl. Microbiol., 84, 661, 10.1046/j.1365-2672.1998.00393.x · doi:10.1046/j.1365-2672.1998.00393.x
  17. Blixt, 1999, Using an electronic nose for determining the spoilage of vacuum-packaged beef, Intl. J. Food Microbiol., 46, 123, 10.1016/S0168-1605(98)00192-5 · doi:10.1016/s0168-1605(98)00192-5
  18. Blum, L.J. (Ed.), 1997. Bio- and chemiluminescent sensors. World Scientific, Singapore, River Edge, NJ, 198 pp. · DOI
  19. Borch, 1996, Bacterial spoilage of meat and cured meat products, Int. J. Food Microbiol., 33, 103, 10.1016/0168-1605(96)01135-X · DOI · Paper page
  20. Bourrounet, 1995, Application of a multi-gas sensor device in the meat industry for boar-taint detection, Sensors Actuators B, 26-27, 250, 10.1016/0925-4005(94)01596-A · doi:10.1016/0925-4005(94)01596-a
  21. Bouvrette, 1995, Development of a flow-injection analysis immunosensor for the detection of E. coli, Intl. J. Food Microbiol., 27, 129, 10.1016/0168-1605(94)00157-2 · doi:10.1016/0168-1605(94)00157-2
  22. Boye, 1991, Bacterial growth control studied by flow cytometry, Res. Microbiol., 142, 131, 10.1016/0923-2508(91)90020-B · doi:10.1016/0923-2508(91)90020-b
  23. Brakstad, 1993, Detection of Staphylococcus aureus with biotinylated monoclonal antibodies directed against staphylococcal Tnase complexed to avidin-peroxidase in a rapid sandwich enzyme-linked immunofiltration assay, J. Med. Microbiol., 39, 128, 10.1099/00222615-39-2-128 · doi:10.1099/00222615-39-2-128
  24. Brayton, 1987, Enumeration of Vibrio-Cholerae 01 in Bangladesh waters by flourescent-antibody direct viable count, Appl. Environ. Microbiol., 53, 2862, 10.1128/AEM.53.12.2862-2865.1987 · doi:10.1128/aem.53.12.2862-2865.1987
  25. Brewster, 1996, Immunoelectrochemical assays for bacteria: use of epifluorescence microscopy in development of an assay for Salmonella, Anal. Chem., 68, 4153, 10.1021/ac9604503 · doi:10.1021/ac9604503
  26. Brewster, 1998, Filtration capture and immunoelectrochemical detection for rapid assay of E. coli O157:H7, J. Immunol. Methods, 211, 1, 10.1016/S0022-1759(97)00161-0 · doi:10.1016/s0022-1759(97)00161-0
  27. Bringham-Burke, 1992, Detection of receptor ligand interactions using surface plasmon resonance: model studies employing the HIV-1 GP120/CD4 interactions, J. Anal. Biochem., 205, 125, 10.1016/0003-2697(92)90588-X · DOI
  28. Brooks, 1990, Sensitive enzyme-amplified electrical immunoassay for protein A-bearing Staphylococcus aureus in foods, Appl. Environ. Microbiol., 56, 3278, 10.1128/AEM.56.11.3278-3284.1990 · doi:10.1128/aem.56.11.3278-3284.1990
  29. Brooks, 1992, Experimental enzyme-linked amperometric immunosensors for the detection of Salmonella in foods, J. Appl. Bacteriol., 73, 189, 10.1111/j.1365-2672.1992.tb02977.x · doi:10.1111/j.1365-2672.1992.tb02977.x
  30. Buchanan, 1997, Foodborne desease significance of E. coli O157:H7 and other enterohemorrhagic E. coli, Food Technol., 51, 69
  31. Bunde, 1998, Piezoelectric quartz-crystal biosensors, Talanta, 46, 1223, 10.1016/S0039-9140(97)00392-5 · doi:10.1016/s0039-9140(97)00392-5
  32. Cao, 1995, Detection of Yersinia pestis Fraction 1 antigen with a fiber optic biosensor, J. Clin. Microbiol., 33, 336, 10.1128/JCM.33.2.336-341.1995 · doi:10.1128/jcm.33.2.336-341.1995
  33. Carter, 1995, Quartz crystal microbalance detection of Vibro cholerae O139 serotype, J. Immunol. Methods, 187, 121, 10.1016/0022-1759(95)00176-B · doi:10.1016/0022-1759(95)00176-b
  34. Chen, 1996, Salmonella detection in eggs using lux+ bacteriophages, J. Food Protect., 59, 908, 10.4315/0362-028X-59.9.908 · doi:10.4315/0362-028x-59.9.908
  35. Chowdhury, 1995, A simplified immunofluorescence technique for detection of viable cells of Vibrio cholerae O1 and O139, J. Microbiol. Methods, 24, 165, 10.1016/0167-7012(95)00066-6 · doi:10.1016/0167-7012(95)00066-6
  36. Clark, 1993, 96-Well apparatus and method for use in enzyme-linked immunofiltration assay, Biotechnol. Tech., 7, 461, 10.1007/BF00155481 · doi:10.1007/bf00155481
  37. Colwell, 1985, Viable but non-culturable Vibrio-Cholerae and related pathogens in the environment: implications for release of genetically engineered microorganisms, Biotechnology, 3, 817, 10.1038/nbt0985-817 · DOI · Paper page
  38. Compton, J.A.F., 1987. Military Chemical and Biological Agents. Telford Press, Caldwell, NJ, 458 pp.
  39. Craven, M.A., Hines E.L., Gardner J.W., Horgan, P., Morgan, D., Ene I.A., 1994. In: Ifeachor, E.C., Rosen, K.G. (Eds.), Neural Networks and Expert Systems in Medicine and Healthcare. University of Plymouth, Plymouth, pp. 226–234.
  40. Cush, 1993, The resonant mirror: a novel optical biosensor for direct sensing of biomolecular interactions, Biosensors Bioelectron., 8, 347, 10.1016/0956-5663(93)80073-X · doi:10.1016/0956-5663(93)80073-x
  41. Dainty, 1992, The relationship between the phenotypic properties of bacteria from chill-stored meat and spoilage processes, J. Appl. Bacteriol., 73, 103S, 10.1111/j.1365-2672.1992.tb03630.x · DOI · Paper page
  42. Dalgaard, 1995, Qualitative and quantitative characterization of spoilage bacteria from packed fish, Int. J. Food Microbiol., 26, 319, 10.1016/0168-1605(94)00137-U · DOI · Paper page
  43. Deng, 1996, In-situ continuous detection of bacteria on the surface of solid medium with a bulk acoustic wave-impedance sensor, J. Microbiol. Methods, 26, 197, 10.1016/0167-7012(96)00914-1 · doi:10.1016/0167-7012(96)00914-1
  44. Deng, 1997, On-line rapid detection of urease-producing bacteria with a novel bulk acoustic wave ammonia sensor, Enzyme Microbial Technol., 21, 258, 10.1016/S0141-0229(97)00039-2 · doi:10.1016/s0141-0229(97)00039-2
  45. Deshpande, 1994, Biosensors and their potential use in food quality-control, Food Technol., 48, 146
  46. DeSilva, 1995, Impedance based sensing of the specific binding reaction between Staphylococcus enterotoxin B and its antibody on an ultra-thin platinum film, Biosensors Bioelectron., 10, 675, 10.1016/0956-5663(95)96958-2 · doi:10.1016/0956-5663(95)96958-2
  47. Dezenclos, 1994, Optimization of the indirect impedancemetry technique — a handy technique for microbial growth measurement, Appl. Microbiol. Biotechnol., 42, 232, 10.1007/BF00902722 · doi:10.1007/bf00902722
  48. DiGleria, 1989, Homogeneous amperometric ligand-binding assay amplified by a proteolytic enzyme cascade, J. Electroanal. Chem., 267, 83, 10.1016/0022-0728(89)80239-6 · DOI
  49. DiNatale, 1997, An electronic nose for food analysis, Sensors Actuators B, 44, 521, 10.1016/S0925-4005(97)00175-5 · doi:10.1016/s0925-4005(97)00175-5
  50. Ding, 1993, Control of microbial activity by flow injection analysis during high cell density cultivation of E. coli, J. Biotechnol., 27, 143, 10.1016/0168-1656(93)90104-U · DOI
  51. Donnelly, 1986, Method for flow-cytometric detction of Listeria-monocytogenes in milk, Appl. Environ. Microbiol., 52, 689, 10.1128/AEM.52.4.689-695.1986 · DOI · Paper page
  52. Duan, 1994, Separation-free sandwich enzyme immunoassays using microporous gold electrodes and self-assembled monolayer/immobilized capture antibodies, Anal. Chem., 66, 1369, 10.1021/ac00081a003 · doi:10.1021/ac00081a003
  53. Dupont, 1996, Rapid estimation of E. coli in live marine bivalve shellfish using automated conductance measurement, J. Appl. Bacteriol., 80, 81, 10.1111/j.1365-2672.1996.tb03193.x · doi:10.1111/j.1365-2672.1996.tb03193.x
  54. Duverlie, 1992, A nylon membrane enzyme immunoassay for rapid diagnosis of Influenza A infection, J. Virol. Methods, 40, 77, 10.1016/0166-0934(92)90009-3 · DOI
  55. Ebato, 1994, Investigation of specific binding of antiflourescyl antibody and FAB to flourescin lipids in langmuir-bladgett deposited films using quartz crystal microbalance, Anal. Chem., 66, 1683, 10.1021/ac00082a014 · doi:10.1021/ac00082a014
  56. Edelman, P.G., Wang, J. (Eds.), 1992. Biosensors and Chemical Sensors: Optimizing Performance through Polymeric Materials. ACS, Washington. · DOI
  57. Eden, R., Eden, G. (Eds.), 1984. Impedance Microbiology. Research Studies Press, Letchworth, Herts, SG 63BE England, John Wiley and Sons, New York.
  58. Ehret, 1997, Monitoring of cellular behaviour by impedance measurements in interdigitated electrode structures, Biosensors Bioelectron., 12, 29, 10.1016/0956-5663(96)89087-7 · DOI · Paper page
  59. Endo, 1996, A biosensor system for the determination of cell number of Enteroccus-Seriolicida, Fisheries Sci., 62, 235, 10.2331/fishsci.62.235 · doi:10.2331/fishsci.62.235
  60. Federal Register, 1990. Assessing defined-substrate technology for meeting monitoring requirements of the total coliform rule. J. Am. Water Works Assoc. 82, 83–87. · doi:10.1002/j.1551-8833.1990.tb07024.x
  61. Fenselau, C. (Ed.), 1994. Mass Spectrometry for the Characterization of Microorganisms. ACS, Washington, DC, 240 pp. · doi:10.1021/bk-1994-0541
  62. Feng, 1992, Commercial assay systems for detecting foodborne Salmonella: a review, J. Food Protect., 55, 927, 10.4315/0362-028X-55.11.927 · doi:10.4315/0362-028x-55.11.927
  63. Feng, 1996, Emergence of rapid methods for identifying microbial pathogens in food, J. AOAC Intl., 79, 809, 10.1093/jaoac/79.3.809 · doi:10.1093/jaoac/79.3.809
  64. Flint, 1993, Evaluation of the TECRA immunocapture ELISA fot the detection of Salmonella typhimurium in foods, Lett. Appl. Microbiol., 17, 4, 10.1111/j.1472-765X.1993.tb01422.x · doi:10.1111/j.1472-765x.1993.tb01422.x
  65. Folley-Thomas, 1995, Phage infection, transfection and transformation of Mycobacteruim tuberculosis by means of luciferase reporter gene, Microbiology, 141, 1173, 10.1099/13500872-141-5-1173 · DOI
  66. Frat Amico, 1998, Detection of E. coli O157:H7 using a surface-plasmon resonance biosensor, Biotechnol. Techn., 12, 571, 10.1023/A:1008872002336 · doi:10.1023/a:1008872002336
  67. Gardner, J.W., Bartlett, P.N. (Eds.), 1992. Sensors and Sensory Systems for an Electronic Nose, NATO ASI Series E: Applied Sciences, vol. 212. Kluwer, Dordrecht. · DOI · Paper page
  68. Gardner, 1994, A brief history of electronic noses, Sensors Actuators B, 18-19, 211
  69. Gardner, 1998, The prediction of bacteria type and culture growth phase by an electronic nose with a multi-layer perceptron network, Measurement Sci. Technol., 9, 120, 10.1088/0957-0233/9/1/016 · doi:10.1088/0957-0233/9/1/016
  70. Gehring, 1996, Enzyme-linked immunomagnetic electrochemical detection of Salmonella typhimurium, J. Immunol. Methods, 195, 15, 10.1016/0022-1759(96)00076-2 · doi:10.1016/0022-1759(96)00076-2
  71. Gehring, 1998, Use of a light-addressable potentiometric sensor for the detection of Eschrichia Coli O157:H7, Anal. Biochem., 258, 293, 10.1006/abio.1998.2597 · doi:10.1006/abio.1998.2597
  72. Ghindilis, 1998, Immunosensors: electrochemical sensing and other engineering approaches, Biosensors Bioelectron., 13, 113, 10.1016/S0956-5663(97)00031-6 · DOI · Paper page
  73. Gibson, 1992, Automated conductance method for the detection of Salmonella in foods: collaborative study, J. Assoc. Off. Anal. Chem., 75, 293
  74. Gibson, 1997, Detection and simultaneous identification of microorganisms from headspace samples using an electronic nose, Sensors Actuators B, 44, 413, 10.1016/S0925-4005(97)00235-9 · doi:10.1016/s0925-4005(97)00235-9
  75. Glazier, 1994, Autofluorescence detection of E. coli on silver membrane filters, J. Microbiol. Methods, 20, 23, 10.1016/0167-7012(94)90060-4 · doi:10.1016/0167-7012(94)90060-4
  76. Goh, 1997, Identification of Staphylococcus species and subspecies by the chaperonin-60 gene identification method and reverse checkerboard hybridization, J. Clin. Microbiol., 35, 3116, 10.1128/JCM.35.12.3116-3121.1997 · DOI
  77. Goepel, 1991, Chemical sensing, molecular electronics, and nanotechnology: interface technologies down to the molecular scale, Sensors Actuators B, 4, 7, 10.1016/0925-4005(91)80172-G · DOI
  78. Goepel, 1995, Interface analysis in biosensor design, Biosensors Bioelectron., 10, 853, 10.1016/0956-5663(95)99225-A · DOI
  79. Gorovits, 1993, New antibody technique using antibody immobilized on a membrane and a flow cuvette as reaction vessel, J. Immunol. Methods, 157, 11, 10.1016/0022-1759(93)90064-E · doi:10.1016/0022-1759(93)90064-e
  80. Graham, 1992, Gene probe assays on a fibre-optic evanescent wave biosensor, Biosenssors Bioelectron., 7, 487, 10.1016/0956-5663(92)80005-V · DOI
  81. Griffin, 1991, The epidemiology of infections caused by E. coli 0157:H7 and other Enterohemorrhagic E. coli, and the associated hemolytic-uremic syndrome, Epidemiol. Rev., 13, 60, 10.1093/oxfordjournals.epirev.a036079 · DOI · Paper page
  82. Griffiths, 1993, Biosensors — What real progress is being made?, Trends Biotechnol., 11, 122, 10.1016/0167-7799(93)90086-O · DOI
  83. Greenberg, A.E., Trussel, R.R., Clesceri, L.S., Franson, M.A.H. (Eds.), 1992. Standard Methods for the Examination of Water and Wastewater. American Pablic Health Association, Washington, DC.
  84. Guschin, 1997, Oligonucleotide microchips as genosensors for determinative and environmental studies in microbiology, Appl. Environ. Microbiol., 63, 2397, 10.1128/AEM.63.6.2397-2402.1997 · DOI · Paper page
  85. Hadley, W.K., Yajko, D.M., 1985. Detection of microorganisms and their metabolism by measurements of electrical impedance. In Nelson, W.H. (Ed.), Instrumental Methods for Rapid Microbiological Analysis. VCH Publishers, pp. 193–211 (Chapter 7).
  86. Hafeman, 1988, Light-addressable potentiometric sensor for biochemical systems, Science, 240, 1182, 10.1126/science.3375810 · DOI · Paper page
  87. Hall, E.A.H. (Ed.), 1990. Biosensors. Open University Press, Milton Keynes, 351 pp.
  88. Harris, 1985, The estimation of mirobial biomass, Biosensors, 1, 17, 10.1016/0265-928X(85)85005-7 · doi:10.1016/0265-928x(85)85005-7
  89. Harteveld, 1997, Detection of Staphylococcal Enterotoxin-B employing a piezoelectric crystal immunosensor, Biosensors Bioelectron., 12, 661, 10.1016/S0956-5663(97)00024-9 · doi:10.1016/s0956-5663(97)00024-9
  90. Haugen, 1998, Electronic nose and artificial neural network, Meat Sci., 49, S273, 10.1016/S0309-1740(98)90054-7 · doi:10.1016/s0309-1740(98)90054-7
  91. Helrich, K., 1990. Official Methods of Analysis of the Association of Official Analytical Chemists, Microbiological Methods, 2, 15 ed. AOAC, Arlington, VA, 425–497 (Chapter 17).
  92. He, 1994, Rapid detection of E. coli using a separated electrode piezoelectric crystal sensor, Anal. Chim. Acta, 289, 313, 10.1016/0003-2670(94)90007-W · DOI
  93. Highfield, 1992, DNA probes for microbial diagnosis, Br. J. Biomed. Sci., 42, 352
  94. Hitchens, 1993, Bacterial activity measurements by mediated amperometry in a flow-injection system, Russian J. Electrochem., 29, 1344
  95. Hobbie, 1977, Use of nucleopore filters for counting bacteria by flourescence microscopy, Appl. Environ. Microbiol., 33, 1225, 10.1128/AEM.33.5.1225-1228.1977 · DOI · Paper page
  96. Hobson, 1996, Microbial Detection, Biosensors Bioelectron., 11, 455, 10.1016/0956-5663(96)86783-2 · DOI
  97. Hock, 1996, Advances in immunochemical detection of microorganisms, Annales De Biologie Clinique, 54, 243
  98. Holland, 1980, Automated detection of microbial growth in blood cultures by using stainless steel electrodes, J. Clin. Microbiol., 12, 180, 10.1128/JCM.12.2.180-184.1980 · doi:10.1128/jcm.12.2.180-184.1980
  99. Holmberg, 1998, Bacteria Classification based on feature extraction from sensor data, Biotechnol. Techn., 12, 319, 10.1023/A:1008862617082 · doi:10.1023/a:1008862617082
  100. Ijsselmuiden, 1989, Optimizing the solid-phase immunofiltration assay. A rapid alternative to immunoassays, J. Immunol. Methods, 119, 35, 10.1016/0022-1759(89)90378-5 · doi:10.1016/0022-1759(89)90378-5
  101. Ivnitski, 1996, A one-step, separation-free amperometric enzyme immunosensor, Biosensors Bioelectron., 11, 409, 10.1016/0956-5663(96)82736-9 · doi:10.1016/0956-5663(96)82736-9
  102. Ivnitski, 1998, An amperometric biosensor for real time analysis of molecular recognition, Bioelectrochem. Bioenerg., 45, 27, 10.1016/S0302-4598(98)00068-3 · doi:10.1016/s0302-4598(98)00068-3
  103. Jay, J.M. (Ed.), 1992. Modern Food Microbiology, fourth ed. Van Nostrand Reinhold, New York. · DOI · Paper page
  104. Jacobs, 1995, A piezoelectric biosensor for listeria-monocytogenes, Am. Lab., 27, 26
  105. Jenkins, 1988, Extending the detection limit of solid-phase electrochemical enzyme immunoassay to the attomolo level, Anal. Biochem., 168, 292, 10.1016/0003-2697(88)90321-1 · doi:10.1016/0003-2697(88)90321-1
  106. Jones, 1993, Detection of Salmonella in oysters using polymerase chain reactions and gene probes, J. Food Sci., 58, 1191, 10.1111/j.1365-2621.1993.tb06146.x · DOI
  107. Jouenne, 1991, Electrochemical assessment of E. coli survival in natural water, Water Res., 25, 829, 10.1016/0043-1354(91)90163-K · doi:10.1016/0043-1354(91)90163-k
  108. Junter, 1980, Electrochemical detection and counting of E. coli in the oresence of a reducible coenzyme, lipoic acid, J. Appl. Environ. Microbiol., 39, 307, 10.1128/AEM.39.2.307-316.1980 · doi:10.1128/aem.39.2.307-316.1980
  109. Kalab, 1994, Evaluation of mediators for development of amperometric microbial bioelectrodes, Electroanalysis, 6, 1004, 10.1002/elan.1140061114 · doi:10.1002/elan.1140061114
  110. Kapperud, 1993, Detection of pathogenic Yersinia Enterocolitica in foods and water by immunomagnetic separtaion, nested polymerase chain reacion, and colorimetric detection of amplified DNA, Appl. Environ. Microbiol., 59, 2938, 10.1128/AEM.59.9.2938-2944.1993 · DOI · Paper page
  111. Karlsson, 1991, Kinetic-analysis of monoclonal antibody-antigen interactions with a new biosensor based analytical system, J. Immunol. Methods, 145, 229, 10.1016/0022-1759(91)90331-9 · DOI · Paper page
  112. Kaspar, 1990, Methods for detecting microbial pathogens in food and water, Methods Microbiol., 22, 497, 10.1016/S0580-9517(08)70253-8 · DOI
  113. Kim, 1995, A novel liposome-based electrochemical biosensor for the detection of haemolytic microorganisms, Biotechnol. Techn., 9, 389, 10.1007/BF00160823 · DOI
  114. Knight, 1990, Gram-negative identification card for identification of Salmonella, E. coli and other Enterobacteriaceae isolated from foods: collaborative study, J. Assoc. Off. Anal. Chem., 73, 729
  115. Koenig, 1993, Detection of human T-Lymphocytes with a piezoelectric immunosensor, Anal. Chim. Acta, 281, 13, 10.1016/0003-2670(93)85334-G · doi:10.1016/0003-2670(93)85334-g
  116. Koenig, 1993, Detection of viruses and bacteria with piezoelectric immunosensors, Anal. Lett., 26, 1567, 10.1080/00032719308021481 · doi:10.1080/00032719308021481
  117. Kress-Rogers, E. (Ed.), 1997. Handbook of Biosensors and Electronic Noses: Medicine, Food, and the Environment. CRC Press, Boca Raton.
  118. Krishnan, 1996, Fast amperometric immunoassay for Hantavirus infection, Electroanalisis, 8, 1131, 10.1002/elan.1140081211 · doi:10.1002/elan.1140081211
  119. Le, 1995, A goat-anti-human IgG modified piezoimmunosensor for Staphylococcus aureus detection, J. Microbiol. Meth., 23, 229, 10.1016/0167-7012(95)00018-G · doi:10.1016/0167-7012(95)00018-g
  120. Lee, W.E., Jacobson, T.V., Thompson, H.G., 1993a. Characteristics of the biochemical detector sensor. Defence Research Establishment Suffield, Canada. Suffield Memorandum No. 1402, pp. 1–23.
  121. Lee, 1993, Rapid immunofiltration assay of Newcastle disease virus using a silicon sensor, J. Immunol. Methods, 166, 123, 10.1016/0022-1759(93)90336-6 · doi:10.1016/0022-1759(93)90336-6
  122. Libby, 1989, Detection of Nesseria meningitidis and Yersinia pestis with a novel silicon-based sensor, J. Clin. Microbiol., 27, 1456, 10.1128/JCM.27.7.1456-1459.1989 · DOI
  123. Litman, 1980, Enzyme channelling immunoassay: a new homogeneous enzyme immunoassay technique, Anal. Biochem., 106, 223, 10.1016/0003-2697(80)90141-4 · doi:10.1016/0003-2697(80)90141-4
  124. Lloyd D. (Ed.), 1993. Flow Cytometry in Microbiology. Springer-Verlag London Limited, Germany, 188 pp. · DOI
  125. Loessner, 1996, Construction of luciferase reporter bacteriophage A511:lux AB for rapid and sensitive detection of viable Listeria cells, Appl. Environ. Microbiol., 62, 1133, 10.1128/AEM.62.4.1133-1140.1996 · DOI · Paper page
  126. Lu, 1997, Development of an amperometric immunosensor based on flow injection analysis for the detection of red blood cells, Anal. Chim. Acta, 340, 175, 10.1016/S0003-2670(96)00453-9 · doi:10.1016/s0003-2670(96)00453-9
  127. Lukosz, 1991, Output grating couplers on planar optical wave-guides as direct immunosensors, Biosensors Bioelectron., 6, 227, 10.1016/0956-5663(91)80007-K · doi:10.1016/0956-5663(91)80007-k
  128. Luong, 1991, The potential role of biosensors in the food and drink industries, Biosensors Bioelectron., 6, 547, 10.1016/0956-5663(91)80018-S · doi:10.1016/0956-5663(91)80018-s
  129. McClelland, 1994, Detection of low levels of specific Salmonella species by fluorescent antibodies and flow cytometry, J. Appl. Bacteriol., 77, 440, 10.1111/j.1365-2672.1994.tb03447.x · DOI
  130. McNamara, 1998, Foodborne pathogens, J. Urban Health Bull. N.Y. Acad. Med., 75, 503, 10.1007/BF02427690 · doi:10.1007/bf02427690
  131. McNeil, 1995, Direct electron transfer bioelectronic interfaces: application to clinical analysis, Biosensors Bioelectron., 10, 75, 10.1016/0956-5663(95)96796-2 · doi:10.1016/0956-5663(95)96796-2
  132. McGown, 1995, The Nucleic Acid ligand a new tool for molecular recognition, Anal. Chem., 1, 663A, 10.1021/ac00117a002 · DOI
  133. Madigan, M.T., Martinko, J.M., Parker, J. (Eds.), 1997. Brock Biology of Microorganisms, eight ed. A Viacom Company Upper Saddle River, NJ, 986 pp.
  134. Malcolm Dando (Ed.), 1994. Biological Warfare in the 21st Century. Brassey’s (UK) London, NY, Macmillan Pab., 258 pp.
  135. Marco, 1996, Environmental applications of analytical biosensors, Meas. Sci. Technol., 7, 1547, 10.1088/0957-0233/7/11/002 · DOI
  136. Matsunaga, 1979, Electrode system for the determination of microbial populations, Appl. Env. Microbiol., 37, 117, 10.1128/AEM.37.1.117-121.1979 · doi:10.1128/aem.37.1.117-121.1979
  137. Medina, 1997, Real-time analysis of antibody binding interactions with immobilized E. coli 0157:H7 cells using the BIAcore, Biotechnol. Techn., 11, 173, 10.1023/A:1018453530459 · doi:10.1023/a:1018453530459
  138. Melamed, M.R., Lindmo, T., Mendelson, M.L. (Eds.), 1990. Flow cytometry and sorting. John Wiley, New York, pp. 105–153.
  139. Meng, 1996, Polymerase chain-reaction for detecting E. coli 0157:H7, Intl. J. Food Microbiol., 32, 103, 10.1016/0168-1605(96)01110-5 · doi:10.1016/0168-1605(96)01110-5
  140. Meng, 1998, Emerging and evolving microbial foodborne pathogens, Bull. Institut Pasteur, 96, 151, 10.1016/S0020-2452(98)80010-9 · DOI
  141. Menking, D.G., Goode, M.T., 1993. Evaluation of cocktailed antibodies for toxin and pathogen assays on the light addressable potentiometric sensor. In: Williams, J.D., Berg, D.A. Reeves, P.J. (Eds.), Proceedings of the 1992 ERDEC Scientific Conference on Chemical Defense Research, 17-20 November, Report No. ERDEC-SP-007, June 1993, pp. 103–109.
  142. Mikkelsen, 1996, Electrochemical biosensors for DNA sequence detection, Electroanalysis, 8, 15, 10.1002/elan.1140080104 · DOI · Paper page
  143. Milner, 1998, Dielectrophoretic classification of bacteria using differential impedance measurements, Electron. Lett., 34, 66, 10.1049/el:19980075 · doi:10.1049/el:19980075
  144. Mirhabibollahi, 1990, A semi-homogeneous amperometric immunosensor for protein A-bearing Staphylococcus aureus in foods, Appl. Microbiol. Biotechnol., 34, 242, 10.1007/BF00166789 · doi:10.1007/bf00166789
  145. Morais, 1997, A comparative study by the enzyme-linked immunofiltration assay of solid-phases used in the development of flow immunosensors, J. Immunol. Methods, 208, 75, 10.1016/S0022-1759(97)00130-0 · doi:10.1016/s0022-1759(97)00130-0
  146. Morgan, 1996, Immunosensors: technology and opportunities in laboratory medicine, Clin. Chem., 42, 193, 10.1093/clinchem/42.2.193 · doi:10.1093/clinchem/42.2.193
  147. Muramatsu, 1986, Piezoelectric immunosensor for the detection of Candida albicans microbes, Anal. Chim. Acta, 188, 257, 10.1016/S0003-2670(00)86049-3 · doi:10.1016/s0003-2670(00)86049-3
  148. Nakamura, 1991, Electrochemical detection of viable bacteria in urine and antibiotic selection, Biosensors Bioelectron., 6, 575, 10.1016/0956-5663(91)80022-P · doi:10.1016/0956-5663(91)80022-p
  149. Nakata, 1990, Discrimination of drinks with a novel sensing system detecting electrochemical non-linearity, Chem. Lett., 9, 1631, 10.1246/cl.1990.1631 · doi:10.1246/cl.1990.1631
  150. Namdev, 1998, Sniffing out trouble:use of an electronic nose in bioprocesses, Biotechnology progress, 14, 75, 10.1021/bp970141d · doi:10.1021/bp970141d
  151. Nelson, W.H. (Ed.), 1985. Instrumental Methods for Rapid Microbiological Analysis. VCH Publishers, USA, 219 pp.
  152. Neufeld, H.A., Pace, J.G., Hutchinson, R.W., 1985. Detection of microorganisms by bio- and chemiluminescence techniques. In: Nelson, W.H. (Ed.), Instrumental Methods for Rapid Microbiological Analysis. VCH Publishers, USA, pp. 51–65 (Chapter 2).
  153. Owen, V.M., 1994. Market requirements for advanced biosensors in healthcare. Biosensors Bioelectronics 9, XXIX-XXXV. · doi:10.1016/0956-5663(94)90024-8
  154. Owicki, 1994, The light addressable potentiometric sensor: principles and biological applications, Ann. Rev. Biophys. Biomol. Struct., 23, 87, 10.1146/annurev.bb.23.060194.000511 · doi:10.1146/annurev.bb.23.060194.000511
  155. Paffard, 1996, A rapid and sensitive enzyme-linked immunofilter assay for whole bacterial-cells, J. Immunol. Methods, 192, 133, 10.1016/0022-1759(96)00029-4 · doi:10.1016/0022-1759(96)00029-4
  156. Palmqvist, 1994, Development of a simple detector for microbial metabolism, based on a polypyrrole resistometric device, Biosensors Bioelectron., 9, 551, 10.1016/0956-5663(94)80047-2 · doi:10.1016/0956-5663(94)80047-2
  157. Pearce, 1993, Electronic nose for monitoring the flavour of beers, Analyst, 118, 371, 10.1039/an9931800371 · DOI · Paper page
  158. Perez, 1998, Immunomagnetic separation with mediated flow-injection analysis amperometric detection of viable E. coli O157, Anal. Chem., 70, 2380, 10.1021/ac970715t · doi:10.1021/ac970715t
  159. Piehler, 1996, Surface modification for direct immunoprobes, Biosensors Bioelectron., 11, 579, 10.1016/0956-5663(96)83293-3 · doi:10.1016/0956-5663(96)83293-3
  160. Pinder, 1990, Validation of flow cytometry for rapid enumeration of bacterial concentrations in pure cultures, J. Appl. Bacteriol., 69, 92, 10.1111/j.1365-2672.1990.tb02916.x · DOI
  161. Pless, 1994, Rapid detection of Salmonella by means of a new impedance-splitting method, J. Food Protect., 57, 369, 10.4315/0362-028X-57.5.369 · doi:10.4315/0362-028x-57.5.369
  162. Plomer, 1992, Development of a piezoelectric immunosensor for the detection of Enterobacteria, Enzyme Microb. Technol., 14, 230, 10.1016/0141-0229(92)90071-U · doi:10.1016/0141-0229(92)90071-u
  163. Pollard-Knight, 1990, Immunoassays and nucleic-acid detection with a biosensor based on surface plasmon resonance, Ann. Biol. Clin., 48, 642
  164. Potter, M.E., Gonzalez-Ayala, S., Silarug, N., 1997. Epidemiology of foodborne diseases. In: Doyle, M.P., Beuchat, L.R., Montville, T.J. (Eds.), Food Microbiology: fundamentals and frontiers. ASM Press, Washington, DC.
  165. Prosser, 1994, Molecular marker systems for the detection of genteically modified microorganisms in the environment, Microbiology, 140, 5, 10.1099/13500872-140-1-5 · doi:10.1099/13500872-140-1-5
  166. Prosser, 1996, Luminescnece-based systems for detection of bacteria in the environment, Crit. Rev. Biotech., 16, 157, 10.3109/07388559609147420 · doi:10.3109/07388559609147420
  167. Prusak-Sochaczewski, 1990, Development of a piezoelectric immunosensor for the detection of Salmonella typhimurium, Enzyme Microbiol. Technol., 12, 173, 10.1016/0141-0229(90)90034-N · doi:10.1016/0141-0229(90)90034-n
  168. Puchades, 1996, Recent developments in flow injection immunoanalysis, Crit. Rev. Anal. Chem., 26, 195, 10.1080/10408349608050574 · doi:10.1080/10408349608050574
  169. Pyle, 1995, A Rapid, direct method for enumerating respiring enterohemorrhagic E. coli O157:H7 in water, Appl. Environ. Microbiol., 61, 2614, 10.1128/AEM.61.7.2614-2619.1995 · DOI
  170. Ramanathan, 1998, Bacteria-based Chemiluminescence sensing system using beta-galactosidase under the control of the ARSR regulatory protein of the ARS Operon, Anal. Chim. Acta, 369, 189, 10.1016/S0003-2670(98)00244-X · DOI
  171. Ramsay, 1988, Development of a electrochemical method for the rapid determination of microbial concentration and evidence for the reaction mechanism, Anal. Chim. Acta, 215, 61, 10.1016/S0003-2670(00)85266-6 · doi:10.1016/s0003-2670(00)85266-6
  172. Rishpon, 1996, Amperometric enzyme-channeling immunosensor, Ann. NY Acad. Sci., 799, 508, 10.1111/j.1749-6632.1996.tb33247.x · doi:10.1111/j.1749-6632.1996.tb33247.x
  173. Rishpon, 1997, An amperometric enzyme-channeling immunosensor, Biosensors Bioelectron., 12, 195, 10.1016/S0956-5663(97)85337-7 · doi:10.1016/s0956-5663(97)85337-7
  174. Rodrigues, 1990, Rapid detection of Salmonellas in raw meats using a fluorescent antibody-microcolony technique, J. Appl. Bacteriol., 68, 213, 10.1111/j.1365-2672.1990.tb02567.x · doi:10.1111/j.1365-2672.1990.tb02567.x
  175. Rogers, K.R., Mulchandani, A., Zhou, W. (Eds.), 1995. Biosensor and Chemical Sensor Technology: process monitoring and control. ACS, Washington, DC, 187 pp. · doi:10.1021/bk-1995-0613
  176. Rowe, 1991, Epidemiology of hemolytic-uremic syndrome in Canadian children from 1986 to 1988, J. Pediatr., 119, 218, 10.1016/S0022-3476(05)80730-9 · doi:10.1016/s0022-3476(05)80730-9
  177. Rossi, T.M., Warner, M., 1985. Bacterial identification using fluorescense spectroscopy. In: Nelson, W.H. (Ed.), Instrumental Methods for Rapid Microbiological Analysis. VCH Publishers, pp. 1–50 (Chapter 1).
  178. Rossi, 1995, Rapid discrimination of Micrococcacae using semiconductor gas sensors, J. Microbiol. Methods, 24, 183, 10.1016/0167-7012(95)00069-0 · DOI
  179. Salzman, G., Singham, S.B., Johnston, R.G., Bohren, C.F., 1990. Light scattering and cytometry. In: Melamed, M.R., Lindmo, T., Mendelsohn, M.L. (Eds.) Flow cytometry and sorting. John Wiley, New York, pp. 105–153.
  180. Sarkis, 1995, Luciferase reporter mycobacteriophages: a sensitive tool for the detection and assay of live mycobacteria, Mol. Microbiol., 15, 1055, 10.1111/j.1365-2958.1995.tb02281.x · DOI
  181. Schaller, 1998, Electronic Noses and their application to food, Food Sci. Technol. Lebensm. Wiss. Technol., 31, 305, 10.1006/fstl.1998.0376 · DOI · Paper page
  182. Schmid, R.D., Scheller, F. (Eds.), 1989. Biosensors: application in medicine, environmental protection, and process control. Weinheim, FRG, New York, USA, VCH.
  183. Schmid, R.D. (Ed.), 1991. Flow Injection Analysis Based on Enzymes or Antibodies. GBF Monographs, vol. 14. Weinheim, Germany. · doi:10.1016/s0003-2670(00)83039-1
  184. Schmitt, 1997, A new method based on acoustic-impedance measurements for quartz immunosensors, Sensors Actuators B-Chem., 43, 217, 10.1016/S0925-4005(97)00155-X · doi:10.1016/s0925-4005(97)00155-x
  185. Schwarz, 1991, Detection of nucleic acid hybridization using surface plasmon resonance, Trends Biotechnol., 9, 339, 10.1016/0167-7799(91)90114-W · doi:10.1016/0167-7799(91)90114-w
  186. Schweizer-Berberich, 1994, Characterisation of food freshness with sensor arrays, Sensors Actuators B, 18-19, 282, 10.1016/0925-4005(94)87095-0 · doi:10.1016/0925-4005(94)87095-0
  187. Sethi, 1994, Transducer aspects of biosensors, Biosensors Bioelectron., 9, 243, 10.1016/0956-5663(94)80127-4 · DOI · Paper page
  188. Sharpe, 1994, Developments in rapid methods for detection of agents of foodborne disease, Food Res. Intl., 27, 237, 10.1016/0963-9969(94)90090-6 · doi:10.1016/0963-9969(94)90090-6
  189. Schneider, 1997, Hartman interferometer: versatile integrated optic sensor for label-free, real-time quantification of nucleic acids, proteins, and pathogens, Clin. Chem., 43, 1757, 10.1093/clinchem/43.9.1757 · doi:10.1093/clinchem/43.9.1757
  190. Silley, 1996, Impedance microbiology: a rapid change for microbiologists, J. Appl. Bacteriol., 80, 233, 10.1111/j.1365-2672.1996.tb03215.x · DOI · Paper page
  191. Skuridin, 1996, A new approach for creating double-stranded DNA biosensors, Biosensors Bioelectron., 11, 903, 10.1016/0956-5663(96)89439-5 · doi:10.1016/0956-5663(96)89439-5
  192. Sloper, 1990, A planar indium phosphate monomode wave-guide evanescent field immunosensor, Sensors Actuators B, 1, 285, 10.1016/0925-4005(90)80279-9 · doi:10.1016/0925-4005(90)80279-9
  193. Slots, 1982, Long-wave UV-light flourescence for identification of black pigmented bacteriodes spp, J. Clin. Microbiol., 16, 1148, 10.1128/JCM.16.6.1148-1151.1982 · doi:10.1128/jcm.16.6.1148-1151.1982
  194. Slutsker, 1998, Foodborne diseases: emerging pathogen and trends, Infect. Dis. Clin. N. Am., 12, 199, 10.1016/S0891-5520(05)70418-9 · DOI
  195. Sperveslage, 1996, Detection of bacterial-contamination, including bacillus spores, in dry growth media and in milk by identification of their 16S RDNA by polymerase chain-reaction, J. Microbiol. Methods, 26, 219, 10.1016/0167-7012(96)00842-1 · doi:10.1016/0167-7012(96)00842-1
  196. Steen, H.B., Skaratad, K., Boye, E., 1990. DNA measurement of bacteria. In: Darzynkiewicz, Z., Crissman, H. (Eds.), Methods in Cell Biology, vol. 33. Academic Press, San Diego, pp. 519–526. · DOI
  197. Stager, 1992, Automated systems for identification of microorganisms, Clin. Microbiol. Rev., 5, 302, 10.1128/CMR.5.3.302 · DOI · Paper page
  198. Suleiman, 1994, Recent developments in piezoelectric immunosensors, Analyst, 119, 2279, 10.1039/an9941902279 · doi:10.1039/an9941902279
  199. Swaminathan, 1994, Rapid detection of food-borne pathogenic bacteria, Annu. Rev. Microbiol., 48, 401, 10.1146/annurev.mi.48.100194.002153 · doi:10.1146/annurev.mi.48.100194.002153
  200. Swenson, 1993, Development and evaluation of optical sensors for the detection of bacteria, Sensors Actuators B, 11, 315, 10.1016/0925-4005(93)85270-K · doi:10.1016/0925-4005(93)85270-k

200 of 228 shown

Cited by

See all 931

Metadata

Authors
Ivnitski, D., Abdel-Hamid, I., Atanasov, P., & Wilkins, E.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
1999-10
Volume
14
Issue
7
Pages
599-624
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2058420239
Cited by
931
References
1
FWCI
15.06
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biosensors for detection of pathogenic bacteria. https://app.cochat.ai/papers/10.1016/s0956-5663(99)00039-1
The paper
Ivnitski, D., Abdel-Hamid, I., Atanasov, P., & Wilkins, E. (1999). Biosensors for detection of pathogenic bacteria. Biosensors and Bioelectronics. https://doi.org/10.1016/s0956-5663(99)00039-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.