Abstract
For native and engineered biological tissues, there exist many physiological, surgical, and medical device applications where multiaxial material characterization and modeling is required. Because biological tissues and many biocompatible elastomers are incompressible, planar biaxial testing allows for a two-dimensional (2-D) stress-state that can be used to fully characterize their three-dimensional (3-D) mechanical properties. Biological tissues exhibit complex mechanical behaviors not easily accounted for in classic elastomeric constitutive models. Accounting for these behaviors by careful experimental evaluation and formulation of constitutive models continues to be a challenging area in biomechanical modeling and simulation. The focus of this review is to describe the application of multiaxial testing techniques to soft tissues and their relation to modern biomechanical constitutive theories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Physics of Rubber Elasticity
Treloar, L. R. G., & Montgomery, D. J. (1959) · Physics Today · doi:10.1063/1.3060678 · Cited by 3,787
The Physics of Rubber Elasticity
G.Treloar, L. R. (2005) · doi:10.1093/oso/9780198570271.001.0001 · Cited by 2,253
Fung, Y.-C. (1993) · Springer eBooks · doi:10.1007/978-1-4757-2257-4 · Cited by 2,051
Large elastic deformations of isotropic materials IV. further developments of the general theory
Rivlin, R. S. (1948) · Philosophical Transactions of the Royal Society of London. Series A, Mathematical and Physical Sciences · doi:10.1098/rsta.1948.0024 · Cited by 1,882
Rupture of rubber. I. Characteristic energy for tearing
Rivlin, R. S., & Thomas, A. G. (1953) · Journal of Polymer Science · doi:10.1002/pol.1953.120100303 · Cited by 1,577
Large elastic deformations of isotropic materials VII. Experiments on the deformation of rubber
Rivlin, R. S., & Saunders, D. W. (1951) · Philosophical Transactions of the Royal Society of London Series A Mathematical and Physical Sciences · doi:10.1098/rsta.1951.0004 · Cited by 1,427
Cardiovascular Solid Mechanics: Cells, Tissues, and Organs
Humphrey, J. D. (2002) · Springer eBooks · doi:10.1007/978-0-387-21576-1 · Cited by 1,027
Constitutive equations for fibrous connective tissues
Lanir, Y. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90041-6 · Cited by 741
Billiar, K. L., & Sacks, M. S. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.429624 · Cited by 441
Self-citationTwo-dimensional mechanical properties of rabbit skin—I. Experimental system
Lanir, Y., & Fung, Y. C. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90067-0 · Cited by 423
Lanir, Y. (1979) · Journal of Biomechanics · doi:10.1016/0021-9290(79)90027-7 · Cited by 396
Shear properties of passive ventricular myocardium
Dokos, S., Smaill, B. H., Young, A. A., & LeGrice, I. J. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00111.2002 · Cited by 373
Billiar, K. L., & Sacks, M. S. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1287158 · Cited by 366
Self-citationDetermination of a Constitutive Relation for Passive Myocardium: I. A New Functional Form
Humphrey, J. D., Strumpf, R. K., & Yin, F. C. P. (1990) · Journal of Biomechanical Engineering · doi:10.1115/1.2891193 · Cited by 352
Two-dimensional mechanical properties of rabbit skin—II. Experimental results
Lanir, Y., & Fung, Y. C. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90058-x · Cited by 350
A small angle light scattering device for planar connective tissue microstructural analysis
Sacks, M. S., Smith, D. B., & Hiester, E. D. (1997) · Annals of Biomedical Engineering · doi:10.1007/bf02684845 · Cited by 295
Self-citationDetermination of a Constitutive Relation for Passive Myocardium: II.—Parameter Estimation
Humphrey, J. D., Strumpf, R. K., & Yin, F. C. P. (1990) · Journal of Biomechanical Engineering · doi:10.1115/1.2891194 · Cited by 275
Yin, F. C. P., Strumpf, R. K., Chew, P. H., & Zeger, S. L. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90279-x · Cited by 203
Sacks, M. S., & Gloeckner, D. C. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199907)46:1<1::aid-jbm1>3.0.co;2-7 · Cited by 176
Self-citationDependence of stress-strain nonlinearity of connective tissues on the geometry of collagen fibres
Comninou, M., & Yannas, I. V. (1976) · Journal of Biomechanics · doi:10.1016/0021-9290(76)90084-1 · Cited by 146
A structural model used to evaluate the changing microstructure of maturing rat skin
Belkoff, S. M., & Haut, R. C. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90335-k · Cited by 107
A Triaxial-Measurement Shear-Test Device for Soft Biological Tissues
Dokos, S., LeGrice, I. J., Smaill, B. H., Kar, J., & Young, A. A. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1289624 · Cited by 95
Yin, F. C. P., Tompkins, W. R., Peterson, K. L., & Intaglietta, M. (1972) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1972.324142 · Cited by 75
Cited by
Design and analysis of tissue engineering scaffolds that mimic soft tissue mechanical anisotropy
Courtney, T., Sacks, M. S., Stankus, J., Guan, J., & Wagner, W. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.02.024 · Cited by 416
Self-citationKhanafer, K., Duprey, A., Schlicht, M., & Berguer, R. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9256-6 · Cited by 273
Aging of the skeletal muscle extracellular matrix drives a stem cell fibrogenic conversion
Stearns-Reider, K. M., D'Amore, A., Beezhold, K., Rothrauff, B., Cavalli, L., Wagner, W. R., Vorp, D. A., Tsamis, A., Shinde, S., Zhang, C., et al. (2017) · Aging Cell · doi:10.1111/acel.12578 · Cited by 265
Mechanical design criteria for intervertebral disc tissue engineering
Nerurkar, N. L., Elliott, D. M., & Mauck, R. L. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.12.001 · Cited by 252
Bernal, M., Nenadic, I., Urban, M. W., & Greenleaf, J. F. (2011) · The Journal of the Acoustical Society of America · doi:10.1121/1.3533735 · Cited by 226
Metadata
- Authors
- Sacks, M. S., & Sun, W.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2003-08
- Volume
- 5
- Issue
- 1
- Pages
- 251-284
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2100541836
- Cited by
- 304
- References
- 23
- FWCI
- 0.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.