The DOI matches its Crossref record.
Magnetization transfer: theory and clinical applications in neuroradiology.
Abstract
Magnetization transfer, a new technique for improving image contrast in magnetic resonance (MR) imaging, is based on application of off-resonance radio-frequency pulses and observing their effects on MR images, as well as measuring the signal intensity with and without application of the pulses (ie, magnetization transfer ratio [MTR]). MTRs can be used to detect changes in the structural status of brain parenchyma that may or may not be visible with standard MR techniques. Use of MTRs may allow subcategorization of multiple sclerosis lesions into those with very low MTR (demyelinated lesions) and slightly decreased MTR (edematous lesions). In cases of wallerian degeneration, use of MTRs appears to allow reliable detection of changes undetectable with MR imaging or even light microscopy. In cases of infection with human immunodeficiency virus, MTRs seem to indicate that the macromolecular structure of white matter remains intact until relatively late in the course of disease. In cases of metastatic disease, MTRs of brain lesions indicate structural changes beyond the extent of the lesions seen on standard MR images. These findings may be due to chronic edema, myelin loss, and perhaps previous undetected tumor. In addition to being a new method of providing contrast, the magnetization transfer technique enables semi-quantitative, reproducible characterization of tissue and pathologic entities, which could substantially improve the specificity of MR imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
DTI and MTR abnormalities in schizophrenia: Analysis of white matter integrity
Kubicki, M., Park, H., Westin, C. F., Nestor, P. G., Mulkern, R. V., Maier, S. E., Niznikiewicz, M., Connor, E. E., Levitt, J. J., Frumin, M., et al. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.026 · Cited by 432
A Model for Magnetization Transfer in Tissues
Morrison, C., & Mark Henkelman, R. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330404 · Cited by 305
Whole brain myelin mapping using T1- and T2-weighted MR imaging data.
Ganzetti, M., Wenderoth, N., & Mantini, D. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00671 · Cited by 225
Lazari, A., & Lipp, I. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.117744 · Cited by 176
Kubicki, M., Niznikiewicz, M., Connor, E., Ungar, L., Nestor, P. G., Bouix, S., Dreusicke, M., Kikinis, R., McCarley, R. W., & Shenton, M. E. (2009) · Brain Imaging and Behavior · doi:10.1007/s11682-009-9061-8 · Cited by 38
Metadata
- Authors
- Grossman, R. I., Gomori, J. M., Ramer, K. N., Lexa, F. J., & Schnall, M. D.
- Venue
- RadioGraphics
- Published
- 1994-03
- Volume
- 14
- Issue
- 2
- Pages
- 279-290
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2070896537
- Cited by
- 231
- References
- 0
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetization transfer: theory and clinical applications in neuroradiology. https://app.cochat.ai/papers/10.1148/radiographics.14.2.8190954
- The paper
- Grossman, R. I., Gomori, J. M., Ramer, K. N., Lexa, F. J., & Schnall, M. D. (1994). Magnetization transfer: theory and clinical applications in neuroradiology. RadioGraphics. https://doi.org/10.1148/radiographics.14.2.8190954
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.