Chemical Shift: The Artifact and Clinical Tool Revisited
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
The chemical shift phenomenon refers to the signal intensity alterations seen in magnetic resonance (MR) imaging that result from the inherent differences in the resonant frequencies of precessing protons. Chemical shift was first recognized as a misregistration artifact of image data. More recently, however, chemical shift has been recognized as a useful diagnostic tool. By exploiting inherent differences in resonant frequencies of lipid and water, fatty elements within tissue can be confirmed with dedicated chemical shift MR pulse sequences. Alternatively, the recognition of chemical shift on images obtained with standard MR pulse sequences may corroborate the diagnosis of lesions with substantial fatty elements. Chemical shift can aid in the diagnosis of lipid-containing lesions of the brain (lipoma, dermoid, and teratoma) or the body (adrenal adenoma, focal fat within the liver, and angiomyolipoma). In addition, chemical shift can be implemented to accentuate visceral margins (e.g., kidney and liver).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MR appearance of hemorrhage in the brain.
Bradley, W. G. (1993) · Radiology · doi:10.1148/radiology.189.1.8372185 · Cited by 754 · cited 1×
“(20) Sagittal out-of-phase FMPSPGR image (50/6, 90°) of a 57-year-old man with known colon cancer shows a”
BackgroundBenign adrenocortical masses: diagnosis with chemical shift MR imaging.
Mitchell, D. G., Crovello, M., Matteucci, T., Petersen, R. O., & Miettinen, M. M. (1992) · Radiology · doi:10.1148/radiology.185.2.1410337 · Cited by 335 · cited 1×
“Chemical shift MR imaging has become a popular technique for diagnosing adrenal adenomas (29-42).”
MethodAdrenal adenomas: relationship between histologic lipid and CT and MR findings.
Korobkin, M., Giordano, T. J., Brodeur, F. J., Francis, I. R., Siegelman, E. S., Quint, L. E., Dunnick, N. R., Heiken, J. P., & Wang, H. H. (1996) · Radiology · doi:10.1148/radiology.200.3.8756925 · Cited by 310 · cited 2×
“368 ■ Scientific Exhibit Volume 19 Number 2 time needed for the breath hold, gradient-echo sequences are commonly performed with the shortest possible TE, which frequently is an out-of-phase TE (4,41,44).”
BackgroundMethodCharacterization of adrenal masses with chemical shift and gadolinium-enhanced MR imaging.
Korobkin, M., Lombardi, T. J., Aisen, A. M., Francis, I. R., Quint, L. E., Dunnick, N. R., Londy, F., Shapiro, B., Gross, M. D., & Thompson, N. W. (1995) · Radiology · doi:10.1148/radiology.197.2.7480685 · Cited by 247 · cited 1×
“Chemical shift MR imaging has become a popular technique for diagnosing adrenal adenomas (29-42).”
MethodMayo-Smith, W. W., Lee, M. J., McNicholas, M. M., Hahn, P. F., Boland, G. W., & Saini, S. (1995) · American Journal of Roentgenology · doi:10.2214/ajr.165.1.7785642 · Cited by 215 · cited 2×
“A decrease in signal intensity of greater than 20% within an adrenal mass on out-of-phase images helps confirm the diagnosis of an adrenal adenoma (40,42).”
BackgroundMethodOutwater, E. K., Siegelman, E. S., Huang, A. B., & Birnbaum, B. A. (1996) · Radiology · doi:10.1148/radiology.200.3.8756926 · Cited by 192 · cited 1×
“Chemical shift MR imaging has become a popular technique for diagnosing adrenal adenomas (29-42).”
MethodOutwater, E. K., Siegelman, E. S., Radecki, P. D., Piccoli, C. W., & Mitchell, D. G. (1995) · American Journal of Roentgenology · doi:10.2214/ajr.165.3.7645474 · Cited by 185 · cited 2×
“Adrenal metastases (Fig 16), on the other hand, typically do not contain any significant lipid elements and will not demonstrate an appreciable change in signal intensity with in-phase and out-of-phase chemical shift imaging (32,33,37,42).”
BackgroundMethodAdrenal masses: differentiation with chemical shift, fast low-angle shot MR imaging.
Tsushima, Y., Ishizaka, H., & Matsumoto, M. (1993) · Radiology · doi:10.1148/radiology.186.3.8430178 · Cited by 184 · cited 1×
“Chemical shift MR imaging has become a popular technique for diagnosing adrenal adenomas (29-42).”
MethodAdrenal masses: evaluation with fast gradient-echo MR imaging and Gd-DTPA-enhanced dynamic studies.
Krestin, G. P., Steinbrich, W., & Friedmann, G. (1989) · Radiology · doi:10.1148/radiology.171.3.2717737 · Cited by 183 · cited 2×
“Adrenal metastases (Fig 16), on the other hand, typically do not contain any significant lipid elements and will not demonstrate an appreciable change in signal intensity with in-phase and out-of-phase chemical shift imaging (32,33,37,42).”
BackgroundMethodFatty liver: Biochemical and clinical considerations
Hoyumpa, A. M., Greene, H. L., Dunn, G. D., & Schenker, S. (1975) · The American Journal of Digestive Diseases · doi:10.1007/bf01070758 · Cited by 178
Cited by
MR Artifacts, Safety, and Quality Control
Zhuo, J., & Gullapalli, R. P. (2006) · RadioGraphics · doi:10.1148/rg.261055134 · Cited by 212
Burns, P. N., & Wilson, S. R. (2007) · Radiology · doi:10.1148/radiol.2421051006 · Cited by 199
The radiological diagnosis and treatment of renal angiomyolipoma—current status
Halpenny, D., Snow, A., McNeill, G., & Torreggiani, W. C. (2010) · Clinical Radiology · doi:10.1016/j.crad.2009.09.014 · Cited by 190
Urinary Bladder Cancer: Role of MR Imaging
Verma, S., Rajesh, A., Prasad, S. R., Gaitonde, K., Lall, C. G., Mouraviev, V., Aeron, G., Bracken, R. B., & Sandrasegaran, K. (2012) · RadioGraphics · doi:10.1148/rg.322115125 · Cited by 178
An Image-based Approach to Understanding the Physics of MR Artifacts
Morelli, J. N., Runge, V. M., Ai, F., Attenberger, U., Vu, L., Schmeets, S. H., Nitz, W. R., & Kirsch, J. E. (2011) · RadioGraphics · doi:10.1148/rg.313105115 · Cited by 171
“The resultant chemical shift artifacts on clinical MR images manifest most prominently at fat-water interfaces such as those in the bladder and the periorbital regions (27).”
BackgroundIntracranial Lesions with High Signal Intensity on T1-weighted MR Images: Differential Diagnosis
Ginat, D. T., & Meyers, S. P. (2012) · RadioGraphics · doi:10.1148/rg.322105761 · Cited by 139
Characterization of lipid-poor adrenal adenoma: chemical-shift MRI and washout CT
Seo, J. M., Park, B. K., Park, S. Y., & Kim, C. K. (2014) · American Journal of Roentgenology · doi:10.2214/ajr.13.11389 · Cited by 130
“Qualitative or quantitative assessment of chemical-shift MR images enhances diagnostic confidence in characterizing adenomas by means of identifying a signal drop at the water-lipid interface [18].”
Background
Metadata
- Authors
- Hood, M. N., Ho, V. B., Smirniotopoulos, J. G., & Szumowski, J.
- Venue
- RadioGraphics
- Published
- 1999-03
- Volume
- 19
- Issue
- 2
- Pages
- 357-371
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2109600647
- Cited by
- 180
- References
- 19
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.