Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 281

The DOI matches its Crossref record.

Dual-Energy CT Virtual Noncalcium Technique: Detecting Posttraumatic Bone Marrow Lesions—Feasibility Study

Pache, Gregor, Krauss, Bernhard, Strohm, Peter, Saueressig, Ulrich, Blanke, Philipp, Bulla, Stefan, Schäfer, Oliver, Helwig, Peter, Kotter, Elmar, Langer, Mathias, Baumann, Tobias·2010·Radiology

Abstract

PURPOSE: To evaluate traumatized bone marrow with a dual-energy (DE) computed tomographic (CT) virtual noncalcium technique. MATERIALS AND METHODS: In this prospective institutional review board-approved study, 21 patients with an acute knee trauma underwent DE CT and magnetic resonance (MR) imaging. A software application was used to virtually subtract calcium from the images. Presence of fractures was noted, and presence of bone bruise was rated on a four-point scale for six femoral and tibial regions by two radiologists. CT numbers were obtained in the same regions. Consensus reading of independently read MR images served as the reference standard. Image ratings and CT numbers were subjected to receiver operating characteristic curve analysis. RESULTS: After exclusion of 16 regions owing to artifacts, MR imaging revealed 59 bone bruises in the remaining 236 regions (19 of 114 femoral, 40 of 122 tibial). Fractures were present in eight patients. Visual rating revealed areas under the curve of 0.886 and 0.897 in the femur and 0.974 and 0.953 in the tibia for observers 1 and 2, respectively. For CT numbers, the respective areas under the curve were 0.922 and 0.974. If scores of 1 and 2 (strong or mild bone bruise) were counted as positive, sensitivities were 86.4% and 86.4% and specificities were 94.4% and 95.5% for observers 1 and 2, respectively. The kappa statistic demonstrated good to excellent agreement (femur, kappa = 0.78; tibia, kappa = 0.87). CONCLUSION: This DE CT virtual noncalcium technique can subtract calcium from cancellous bone, allowing bone marrow assessment and potentially making posttraumatic bone bruises of the knee detectable with CT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.10091230

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 281

Metadata

Authors
Pache, G., Krauss, B., Strohm, P., Saueressig, U., Blanke, P., Bulla, S., Schäfer, O., Helwig, P., Kotter, E., Langer, M., & Baumann, T.
Venue
Radiology
Published
2010-08
Volume
256
Issue
2
Pages
617-624
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2112191535
Cited by
281
References
0
FWCI
5.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dual-Energy CT Virtual Noncalcium Technique: Detecting Posttraumatic Bone Marrow Lesions—Feasibility Study. https://app.cochat.ai/papers/10.1148/radiol.10091230
The paper
Pache, G., Krauss, B., Strohm, P., Saueressig, U., Blanke, P., Bulla, S., Schäfer, O., Helwig, P., Kotter, E., Langer, M., & Baumann, T. (2010). Dual-Energy CT Virtual Noncalcium Technique: Detecting Posttraumatic Bone Marrow Lesions—Feasibility Study. Radiology. https://doi.org/10.1148/radiol.10091230

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.