The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Dual-Energy CT Virtual Noncalcium Technique: Detecting Posttraumatic Bone Marrow Lesions—Feasibility Study
Abstract
PURPOSE: To evaluate traumatized bone marrow with a dual-energy (DE) computed tomographic (CT) virtual noncalcium technique. MATERIALS AND METHODS: In this prospective institutional review board-approved study, 21 patients with an acute knee trauma underwent DE CT and magnetic resonance (MR) imaging. A software application was used to virtually subtract calcium from the images. Presence of fractures was noted, and presence of bone bruise was rated on a four-point scale for six femoral and tibial regions by two radiologists. CT numbers were obtained in the same regions. Consensus reading of independently read MR images served as the reference standard. Image ratings and CT numbers were subjected to receiver operating characteristic curve analysis. RESULTS: After exclusion of 16 regions owing to artifacts, MR imaging revealed 59 bone bruises in the remaining 236 regions (19 of 114 femoral, 40 of 122 tibial). Fractures were present in eight patients. Visual rating revealed areas under the curve of 0.886 and 0.897 in the femur and 0.974 and 0.953 in the tibia for observers 1 and 2, respectively. For CT numbers, the respective areas under the curve were 0.922 and 0.974. If scores of 1 and 2 (strong or mild bone bruise) were counted as positive, sensitivities were 86.4% and 86.4% and specificities were 94.4% and 95.5% for observers 1 and 2, respectively. The kappa statistic demonstrated good to excellent agreement (femur, kappa = 0.78; tibia, kappa = 0.87). CONCLUSION: This DE CT virtual noncalcium technique can subtract calcium from cancellous bone, allowing bone marrow assessment and potentially making posttraumatic bone bruises of the knee detectable with CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
Material differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510
First performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413
Self-citationVogler, J. B., & Murphy, W. A. (1988) · Radiology · doi:10.1148/radiology.168.3.3043546 · Cited by 732
Mink, J. H., & Deutsch, A. L. (1989) · Radiology · doi:10.1148/radiology.170.3.2916038 · Cited by 467
Vertebral bone mineral analysis: an integrated approach with CT.
Kalender, W. A., Klotz, E., & Suess, C. (1987) · Radiology · doi:10.1148/radiology.164.2.3602380 · Cited by 204
Chandarana, H., Godoy, M. C. B., Vlahos, I., Graser, A., Babb, J., Leidecker, C., & Macari, M. (2008) · Radiology · doi:10.1148/radiol.2492080359 · Cited by 164
Follow-up of Occult Bone Lesions Detected at MR Imaging: Systematic Review
Boks, S. S., Vroegindeweij, D., Koes, B. W., Hunink, M. G. M., & Bierma‐Zeinstra, S. (2006) · Radiology · doi:10.1148/radiol.2382050062 · Cited by 111
Mandalia, V., Fogg, A. J. B., Chari, R., Murray, J., Beale, A., & Henson, J. H. L. (2005) · Clinical Radiology · doi:10.1016/j.crad.2005.01.014 · Cited by 105
Bone mineral assessment: new dual-energy CT approach.
Nickoloff, E. L., Feldman, F., & Atherton, J. V. (1988) · Radiology · doi:10.1148/radiology.168.1.3380964 · Cited by 76
Cited by
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
McCollough, C. H., Leng, S., Yu, L., & Fletcher, J. G. (2015) · Radiology · doi:10.1148/radiol.2015142631 · Cited by 1,598
Photon-counting CT: Technical Principles and Clinical Prospects
Willemink, M. J., Persson, M., Pourmorteza, A., Pelc, N. J., & Fleischmann, D. (2018) · Radiology · doi:10.1148/radiol.2018172656 · Cited by 1,326
Dual-Energy CT: New Horizon in Medical Imaging
Goo, H. W., & Goo, J. M. (2017) · Korean Journal of Radiology · doi:10.3348/kjr.2017.18.4.555 · Cited by 408
Material Separation Using Dual-Energy CT: Current and Emerging Applications
Patino, M., Prochowski, A., Agrawal, M. D., Simeone, F. J., Gupta, R., Hahn, P. F., & Sahani, D. V. (2016) · RadioGraphics · doi:10.1148/rg.2016150220 · Cited by 328
Dual-Energy CT for the Musculoskeletal System
Mallinson, P. I., Coupal, T. M., McLaughlin, P. D., Nicolaou, S., Munk, P. L., & Ouellette, H. A. (2016) · Radiology · doi:10.1148/radiol.2016151109 · Cited by 242
Metadata
- Authors
- Pache, G., Krauss, B., Strohm, P., Saueressig, U., Blanke, P., Bulla, S., Schäfer, O., Helwig, P., Kotter, E., Langer, M., & Baumann, T.
- Venue
- Radiology
- Published
- 2010-08
- Volume
- 256
- Issue
- 2
- Pages
- 617-624
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2112191535
- Cited by
- 281
- References
- 12
- FWCI
- 5.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.