The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Photon-counting CT: Technical Principles and Clinical Prospects
Open accessAbstract
Photon-counting CT is an emerging technology with the potential to dramatically change clinical CT. Photon-counting CT uses new energy-resolving x-ray detectors, with mechanisms that differ substantially from those of conventional energy-integrating detectors. Photon-counting CT detectors count the number of incoming photons and measure photon energy. This technique results in higher contrast-to-noise ratio, improved spatial resolution, and optimized spectral imaging. Photon-counting CT can reduce radiation exposure, reconstruct images at a higher resolution, correct beam-hardening artifacts, optimize the use of contrast agents, and create opportunities for quantitative imaging relative to current CT technology. In this review, the authors will explain the technical principles of photon-counting CT in nonmathematical terms for radiologists and clinicians. Following a general overview of the current status of photon-counting CT, they will explain potential clinical applications of this technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
Berrington de González, A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.440 · Cited by 1,888
Material differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510
Vision 20/20: Single photon counting x‐ray detectors in medical imaging
Taguchi, K., & Iwanczyk, J. S. (2013) · Medical Physics · doi:10.1118/1.4820371 · Cited by 948
Schlomka, J. P., Roessl, E., Dorscheid, R., Dill, S., Martens, G., Istel, T., Bäumer, C., Herrmann, C., Steadman, R., Zeitler, G., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/002 · Cited by 801
Cardiac Computed Tomography Writing Group, Taylor, A. J., Cerqueira, M., Hodgson, J. M., Mark, D., Min, J., O'Gara, P., & Rubin, G. D. (2010) · Circulation · doi:10.1161/cir.0b013e3181fcae66 · Cited by 647
K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors
Roessl, E., & Proksa, R. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/15/020 · Cited by 558
Atherosclerotic Plaque Composition: Analysis with Multicolor CT and Targeted Gold Nanoparticles
Cormode, D. P., Roessl, E., Thran, A., Skajaa, T., Gordon, R. E., Schlomka, J.-P., Fuster, V., Fisher, E. A., Mulder, W. J. M., Proksa, R., et al. (2010) · Radiology · doi:10.1148/radiol.10092473 · Cited by 479
Iterative reconstruction techniques for computed tomography Part 1: Technical principles
Willemink, M. J., de Jong, P. A., Leiner, T., de Heer, L. M., Nievelstein, R. A. J., Budde, R. P. J., & Schilham, A. M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2765-y · Cited by 443
Self-citationVirtual monochromatic imaging in dual‐source dual‐energy CT: Radiation dose and image quality
Yu, L., Christner, J. A., Leng, S., Wang, J., Fletcher, J. G., & McCollough, C. H. (2011) · Medical Physics · doi:10.1118/1.3658568 · Cited by 343
Cited by
Willemink, M. J., & Noël, P. B. (2019) · European Radiology · doi:10.1007/s00330-018-5810-7 · Cited by 603
Self-citationFlohr, T., Petersilka, M., Henning, A., Ulzheimer, S., Ferda, J., & Schmidt, B. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.10.030 · Cited by 581
Deep Learning Image Reconstruction for CT: Technical Principles and Clinical Prospects
Koetzier, L. R., Mastrodicasa, D., Szczykutowicz, T. P., van der Werf, N. R., Wang, A. S., Sandfort, V., van der Molen, A. J., Fleischmann, D., & Willemink, M. J. (2023) · Radiology · doi:10.1148/radiol.221257 · Cited by 427
Self-citationHe, Y., Hadar, I., & Kanatzidis, M. G. (2022) · Nature Photonics · doi:10.1038/s41566-021-00909-5 · Cited by 301
Multiscale X-ray tomography of cementitious materials: A review
Brisard, S., Serdar, M., & Monteiro, P. J. M. (2020) · Cement and Concrete Research · doi:10.1016/j.cemconres.2019.105824 · Cited by 260
Metadata
- Authors
- Willemink, M. J., Persson, M., Pourmorteza, A., Pelc, N. J., & Fleischmann, D.
- Venue
- Radiology
- Published
- 2018-11
- Volume
- 289
- Issue
- 2
- Pages
- 293-312
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2889741596
- Cited by
- 1,326
- References
- 42
- FWCI
- 19.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photon-counting CT: Technical Principles and Clinical Prospects. https://app.cochat.ai/papers/10.1148/radiol.2018172656
- The paper
- Willemink, M. J., Persson, M., Pourmorteza, A., Pelc, N. J., & Fleischmann, D. (2018). Photon-counting CT: Technical Principles and Clinical Prospects. Radiology. https://doi.org/10.1148/radiol.2018172656
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.