The DOI matches its Crossref record.
Identification of Intraarticular and Periarticular Uric Acid Crystals with Dual-Energy CT: Initial Evaluation
Abstract
PURPOSE: To estimate the accuracy, sensitivity, specificity, and interobserver agreement of dual-energy computed tomography (CT) in detection of uric acid crystals in joints or periarticular structures in patients with arthralgia and patients suspected of having gout, with joint aspiration results as reference standard. MATERIALS AND METHODS: With institutional review board approval, patient consent, and HIPAA compliance, 94 patients (age range, 29-89 years) underwent dual-source, dual-energy (80 and 140 kVp) CT of a painful joint. A material decomposition algorithm was used to identify uric acid. Two blinded musculoskeletal radiologists evaluated the dual-energy CT images and classified the examination findings as positive or negative for the presence of uric acid crystals. Reference standard was the result of joint aspiration. RESULTS: Forty-three of 94 patients (46%) underwent attempted joint aspiration within 1 month of dual-energy CT. Aspiration was successful in 31 of 43 patients (72%). In 12 of 31 patients (39%), uric acid crystals were identified at joint aspiration; in 19 patients, they were not. Readers 1 and 2 had no false-negative findings for uric acid at dual-energy CT. Sensitivity was 100% (12 of 12; 95% confidence interval (CI): 74%, 100%) for both readers. Specificity was 89% (17 of 19; 95% CI: 67%, 99% ) for reader 1 and 79% (15 of 19; 95% CI: 54%, 94%) for reader 2, with near-perfect agreement between the readers (κ = 0.87; range, 0.70-1.00) in the 31 patients who underwent aspiration. CONCLUSION: Initial retrospective assessment suggests that dual-energy CT is a sensitive, noninvasive, and reproducible method for identifying uric acid deposits in joints and periarticular soft tissues in patients suspected of having gout.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
McCollough, C. H., Leng, S., Yu, L., & Fletcher, J. G. (2015) · Radiology · doi:10.1148/radiol.2015142631 · Cited by 1,598
Self-citationNeogi, T., Jansen, T. L. T. A., Dalbeth, N., Fransen, J., Schumacher, H. R., Berendsen, D., Brown, M., Choi, H., Edwards, N. L., Janssens, H. J. E. M., et al. (2015) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2015-208237 · Cited by 888
Neogi, T., Jansen, T. L. T. A., Dalbeth, N., Fransen, J., Schumacher, H. R., Berendsen, D., Brown, M., Choi, H., Edwards, N. L., Janssens, H. J. E. M., et al. (2015) · Arthritis & Rheumatology · doi:10.1002/art.39254 · Cited by 669
Dual-Energy CT–Based Monochromatic Imaging
Yu, L., Leng, S., & McCollough, C. H. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.12.9121 · Cited by 609
Self-citationGout: An old disease in new perspective – A review
Ragab, G., Elshahaly, M., & Bardin, T. (2017) · Journal of Advanced Research · doi:10.1016/j.jare.2017.04.008 · Cited by 599
Metadata
- Authors
- Glazebrook, K. N., Guimarães, L. S., Murthy, N. S., Black, D. F., Bongartz, T., J. Manek, N., Leng, S., Fletcher, J. G., & McCollough, C. H.
- Venue
- Radiology
- Published
- 2011-11
- Volume
- 261
- Issue
- 2
- Pages
- 516-524
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2009110061
- Cited by
- 242
- References
- 0
- FWCI
- 12.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Identification of Intraarticular and Periarticular Uric Acid Crystals with Dual-Energy CT: Initial Evaluation. https://app.cochat.ai/papers/10.1148/radiol.11102485
- The paper
- Glazebrook, K. N., Guimarães, L. S., Murthy, N. S., Black, D. F., Bongartz, T., J. Manek, N., Leng, S., Fletcher, J. G., & McCollough, C. H. (2011). Identification of Intraarticular and Periarticular Uric Acid Crystals with Dual-Energy CT: Initial Evaluation. Radiology. https://doi.org/10.1148/radiol.11102485
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.