The DOI matches its Crossref record.
Identification of Intraarticular and Periarticular Uric Acid Crystals with Dual-Energy CT: Initial Evaluation
Abstract
PURPOSE: To estimate the accuracy, sensitivity, specificity, and interobserver agreement of dual-energy computed tomography (CT) in detection of uric acid crystals in joints or periarticular structures in patients with arthralgia and patients suspected of having gout, with joint aspiration results as reference standard. MATERIALS AND METHODS: With institutional review board approval, patient consent, and HIPAA compliance, 94 patients (age range, 29-89 years) underwent dual-source, dual-energy (80 and 140 kVp) CT of a painful joint. A material decomposition algorithm was used to identify uric acid. Two blinded musculoskeletal radiologists evaluated the dual-energy CT images and classified the examination findings as positive or negative for the presence of uric acid crystals. Reference standard was the result of joint aspiration. RESULTS: Forty-three of 94 patients (46%) underwent attempted joint aspiration within 1 month of dual-energy CT. Aspiration was successful in 31 of 43 patients (72%). In 12 of 31 patients (39%), uric acid crystals were identified at joint aspiration; in 19 patients, they were not. Readers 1 and 2 had no false-negative findings for uric acid at dual-energy CT. Sensitivity was 100% (12 of 12; 95% confidence interval (CI): 74%, 100%) for both readers. Specificity was 89% (17 of 19; 95% CI: 67%, 99% ) for reader 1 and 79% (15 of 19; 95% CI: 54%, 94%) for reader 2, with near-perfect agreement between the readers (κ = 0.87; range, 0.70-1.00) in the 31 patients who underwent aspiration. CONCLUSION: Initial retrospective assessment suggests that dual-energy CT is a sensitive, noninvasive, and reproducible method for identifying uric acid deposits in joints and periarticular soft tissues in patients suspected of having gout.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
McCollough, C. H., Leng, S., Yu, L., & Fletcher, J. G. (2015) · Radiology · doi:10.1148/radiol.2015142631 · Cited by 1,598
Self-citationNeogi, T., Jansen, T. L. T. A., Dalbeth, N., Fransen, J., Schumacher, H. R., Berendsen, D., Brown, M., Choi, H., Edwards, N. L., Janssens, H. J. E. M., et al. (2015) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2015-208237 · Cited by 888
Neogi, T., Jansen, T. L. T. A., Dalbeth, N., Fransen, J., Schumacher, H. R., Berendsen, D., Brown, M., Choi, H., Edwards, N. L., Janssens, H. J. E. M., et al. (2015) · Arthritis & Rheumatology · doi:10.1002/art.39254 · Cited by 669
Dual-Energy CT–Based Monochromatic Imaging
Yu, L., Leng, S., & McCollough, C. H. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.12.9121 · Cited by 609
Self-citationGout: An old disease in new perspective – A review
Ragab, G., Elshahaly, M., & Bardin, T. (2017) · Journal of Advanced Research · doi:10.1016/j.jare.2017.04.008 · Cited by 599
Richette, P., Doherty, M., Pascual, E., Barskova, V., Becce, F., Castaneda, J., Coyfish, M., Guillo, S., Jansen, T., Janssens, H., et al. (2020) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2019-215315 · Cited by 440
Virtual monochromatic imaging in dual‐source dual‐energy CT: Radiation dose and image quality
Yu, L., Christner, J. A., Leng, S., Wang, J., Fletcher, J. G., & McCollough, C. H. (2011) · Medical Physics · doi:10.1118/1.3658568 · Cited by 343
Self-citationThe British Society for Rheumatology Guideline for the Management of Gout
Hui, M., Carr, A., Cameron, S., Davenport, G., Doherty, M., Forrester, H., Jenkins, W., Jordan, K. M., Mallen, C. D., McDonald, T. M., et al. (2017) · Rheumatology · doi:10.1093/rheumatology/kex156 · Cited by 316
Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study
Bongartz, T., Glazebrook, K. N., Kavros, S. J., Murthy, N. S., Merry, S. P., Franz, W. B., Michet, C. J., Veetil, B. M. A., Davis, J. M., Mason, T. G., et al. (2015) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2013-205095 · Cited by 276
Self-citationSivera, F., Andrés, M., Carmona, L., Kydd, A. S. R., Moi, J., Seth, R., Sriranganathan, M., van Durme, C., van Echteld, I., Vinik, O., et al. (2014) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2013-203325 · Cited by 262
Dual-Energy CT for the Musculoskeletal System
Mallinson, P. I., Coupal, T. M., McLaughlin, P. D., Nicolaou, S., Munk, P. L., & Ouellette, H. A. (2016) · Radiology · doi:10.1148/radiol.2016151109 · Cited by 242
Metadata
- Authors
- Glazebrook, K. N., Guimarães, L. S., Murthy, N. S., Black, D. F., Bongartz, T., J. Manek, N., Leng, S., Fletcher, J. G., & McCollough, C. H.
- Venue
- Radiology
- Published
- 2011-11
- Volume
- 261
- Issue
- 2
- Pages
- 516-524
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2009110061
- Cited by
- 242
- References
- 0
- FWCI
- 12.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.