Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 159

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Diagnostic Performance of Dual-Energy CT for the Detection of Traumatic Bone Marrow Lesions in the Ankle: Comparison with MR Imaging

Guggenberger, Roman, Gnannt, Ralph, Hodler, Juerg, Krauss, Bernhard, Wanner, Guido A., Csuka, Esther, Payne, Barbara, Frauenfelder, Thomas, Andreisek, Gustav, Alkadhi, Hatem · 2012 · Radiology

Abstract

PURPOSE: To evaluate prospectively the performance of noncalcium images reconstructed from dual-energy (DE) computed tomography (CT) for the diagnosis of bone marrow lesions in patients with acute ankle joint trauma in comparison with magnetic resonance (MR) images. MATERIALS AND METHODS: The study had local ethics board approval, and written informed consent was obtained. Thirty consecutive patients (15 women; mean age, 34 years±11.8 [standard deviation]) underwent dual-source DE CT (80 kVp and 140 kVp with tin filter) and MR imaging within 1 day following acute ankle trauma. DE CT data were postprocessed by using a three-material decomposition algorithm for generating noncalcium images. MR and noncalcium images were graded by two blinded, independent readers using a four-point system (1=distinct bone marrow lesion, 4=no lesion); CT numbers in noncalcium images were calculated by a third reader. MR imaging interpretations served as the reference standard. RESULTS: Interreader agreement for qualitative grading of DE CT images was substantial (κ=0.66). The respective sensitivity, specificity, positive predictive value, and negative predictive value of DE CT for depicting distinct bone marrow lesions for both readers were 90.0% each, 80.5% and 81.6%, 25.4% and 26.5%, and 99.1% each. In regions without abnormality, CT numbers in noncalcium images gradually increased from proximal to distal location (P<.001). Significant differences in CT numbers were found in regions positive for bone marrow lesions compared with those that were negative (P<.001). CT numbers for the diagnosis of distinct bone marrow lesions according to MR imaging revealed areas under the receiver operating characteristic curve of 0.973, 0.813, and 0.758 for ankle mortise, talar dome, and talar body/head, respectively. CONCLUSION: Compared with MR images, distinct traumatic bone marrow lesions of the ankle joint can be diagnosed on noncalcium images reconstructed from DE CT with high sensitivity and excellent negative predictive value, but with moderate specificity and low positive predictive value.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.12112217

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 159

Metadata

Authors
Guggenberger, R., Gnannt, R., Hodler, J., Krauss, B., Wanner, G. A., Csuka, E., Payne, B., Frauenfelder, T., Andreisek, G., & Alkadhi, H.
Venue
Radiology
Published
2012-07
Volume
264
Issue
1
Pages
164-173
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2145177147
Cited by
159
References
2
FWCI
4.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic Performance of Dual-Energy CT for the Detection of Traumatic Bone Marrow Lesions in the Ankle: Comparison with MR Imaging. https://app.cochat.ai/papers/10.1148/radiol.12112217
The paper
Guggenberger, R., Gnannt, R., Hodler, J., Krauss, B., Wanner, G. A., Csuka, E., Payne, B., Frauenfelder, T., Andreisek, G., & Alkadhi, H. (2012). Diagnostic Performance of Dual-Energy CT for the Detection of Traumatic Bone Marrow Lesions in the Ankle: Comparison with MR Imaging. Radiology. https://doi.org/10.1148/radiol.12112217

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.