Intravoxel Incoherent Motion Diffusion-weighted MR Imaging for Characterization of Focal Pancreatic Lesions
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the diagnostic potential of apparent diffusion coefficient (ADC) and intravoxel incoherent motion (IVIM)-derived parameters for differentiation of common pancreatic tumors, chronic pancreatitis, and normal pancreas and for characterization of the malignancy potential of intraductal papillary mucinous neoplasms (IPMNs). MATERIALS AND METHODS: The institutional review board approved this retrospective study, and informed consent was waived. Ninety-three consecutive patients with surgically resected and pathologically confirmed pancreatic tumors (39 pancreatic adenocarcinomas [PACs], 17 neuroendocrine tumors [NETs], and 37 IPMNs), seven patients with chronic pancreatitis, and 26 patients with a normal pancreas were included in this study. All patients underwent pancreatic 3.0-T magnetic resonance imaging, including IVIM diffusion-weighted imaging with 10 b values used (from 0 to 1000 sec/mm(2)). The ADC, slow component of diffusion (D(slow)), incoherent microcirculation (D(fast)), and perfusion fraction (f) were calculated. Steel-Dwass and Mann-Whitney U tests were used for comparison. The diagnostic performance of the parameters was evaluated by using receiver operating characteristic (ROC) analysis with Bonferroni correction. RESULTS: Among ADC- and IVIM-derived parameters, D(fast) and f values of PACs were significantly lower than those of normal pancreas, chronic pancreatitis, and NETs (all P < .05 in post hoc analyses). For differentiation of PACs from NETs, f and D(fast) showed a significant difference (P < .0001 for both) and were more useful parameters than ADC and D(slow) in ROC analysis (all P < .05). Malignant IPMNs had significantly lower ADC and D(slow) values and higher D(fast) and f values when compared with benign IPMNs (all P < .05). In ROC analysis, f showed the highest area under the ROC curve value for distinguishing malignant from benign IPMNs. CONCLUSION: IVIM-derived perfusion-related parameters could be helpful for the differentiation of common malignant tumors in the pancreas and for distinguishing malignant from benign IPMNs. D(fast) and f were more valuable parameters in the differentiation of PACs from NETs than were ADC and D(slow).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jemal, A., Siegel, R., Ward, E., Hao, Y., Xu, J., & Thun, M. J. (2009) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20006 · Cited by 9,709
Spencer, P. M., Cameron, J. L., & Lin, L. (2000) · Cited by 7,202
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912 · cited 1×
“In the IVIM model, the relationship between signal variation and b factors is expressed as (20):”
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169 · cited 1×
“However, earlier studies have also demonstrated that the diffusion-weighted signal and ADC values can be influenced not only by molecular diffusion but also through microcirculation, or blood perfusion, and, therefore, ADC values containing perfusion effect may limit the reliability of ADC in characterizing pancreatic…”
BackgroundLi, D., Xie, K., Wolff, R., & Abbruzzese, J. L. (2004) · The Lancet · doi:10.1016/s0140-6736(04)15841-8 · Cited by 1,719 · cited 1×
“Technical support was (MR) imaging, assigning the correct diagnosis of pancreatic neoplasms on the basis of those anatomic imaging tests still remains challenging, owing to overlapping imaging features (9).”
MethodIntravoxel Incoherent Motion in Body Diffusion-Weighted MRI: Reality and Challenges
Koh, D.-M., Collins, D. J., & Orton, M. R. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5515 · Cited by 527 · cited 1×
“Therefore, referencing the recommendations of Koh et al (21) and Lemke (24) that a minimum number of b values used for IVIM DW imaging could be eight and 10, respectively, we used 10 b values in total and six b values lower than 200 sec/mm2.”
MethodFocal liver masses: characterization with diffusion-weighted echo-planar MR imaging.
Namimoto, T., Yamashita, Y., Sumi, S., Tang, Y., & Takahashi, M. (1997) · Radiology · doi:10.1148/radiology.204.3.9280252 · Cited by 349
Toward an optimal distribution of b values for intravoxel incoherent motion imaging
Lemke, A., Stieltjes, B., Schad, L. R., & Laun, F. B. (2011) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2011.03.004 · Cited by 286 · cited 2×
“Consistent with the present findings, in previous studies, Lemke et al (22) and Re et al (27) reported that the f value in pancreatic cancer was markedly reduced when compared with healthy pancreatic tissue.”
MethodYoon, S. H., Lee, J. M., Cho, J. Y., Lee, K. B., Kim, J. E., Moon, S. K., Kim, S. J., Baek, J. H., Kim, S. H., Kim, S. H., et al. (2011) · Radiology · doi:10.1148/radiol.11101133 · Cited by 257 · cited 1×
“Yet, atypical enhancement patterns of PACs or NETs are not rare at dynamic MR imaging or CT (28,29) because of tumor size, degree of differentiation, and PAC from NP, CP, and NETs.”
BackgroundSelf-citationNew MRI Grading System for the Cervical Canal Stenosis
Kang, Y., Lee, J. W., Koh, Y. H., Hur, S., Kim, S. J., Chai, J. W., & Kang, H. S. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5560 · Cited by 234 · cited 1×
“75 indicate excellent reproducibility (25).”
Self-citationLemke, A., Laun, F. B., Klau, M., Re, T. J., Simon, D., Delorme, S., Schad, L. R., & Stieltjes, B. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e3181b62271 · Cited by 231 · cited 11×
“Yet, atypical enhancement patterns of PACs or NETs are not rare at dynamic MR imaging or CT (28,29) because of tumor size, degree of differentiation, and PAC from NP, CP, and NETs.”
BackgroundResultInfluentialKwee, T. C., Takahara, T., Koh, D., Nievelstein, R. A. J., & Luijten, P. R. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21569 · Cited by 229
Lee, S. S., Byun, J. H., Park, B. J., Park, S. H., Kim, N., Park, B., Kim, J. K., & Lee, M. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21508 · Cited by 198
Neuroendocrine tumors of the pancreas: Spectrum of appearances on MRI
Semelka, R. C., Custodio, C. M., Balci, N. C., & Woosley, J. T. (2000) · Journal of Magnetic Resonance Imaging · Cited by 197
Chandarana, H., Lee, V. S., Hecht, E., Taouli, B., & Sigmund, E. E. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e3181ffc485 · Cited by 188 · cited 1×
“However, earlier studies have also demonstrated that the diffusion-weighted signal and ADC values can be influenced not only by molecular diffusion but also through microcirculation, or blood perfusion, and, therefore, ADC values containing perfusion effect may limit the reliability of ADC in characterizing pancreatic…”
BackgroundPelaez-Luna, M., Takahashi, N., Fletcher, J. G., & Chari, S. T. (2007) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2007.01480.x · Cited by 180
Sumi, M., Van Cauteren, M., Sumi, T., Obara, M., Ichikawa, Y., & Nakamura, T. (2012) · Radiology · doi:10.1148/radiol.12111248 · Cited by 177 · cited 1×
“For the comparison of ADC, Dslow, Dfast, and f values among the NP, CP, PAC, NETs, and IPMNs, data were analyzed by using the Kruskal-Wallis test and Steel-Dwass test of post hoc nonparametric multiple comparison (26).”
MethodDiffusion-weighted MR Imaging of Solid and Cystic Lesions of the Pancreas
Wang, Y., Miller, F. H., Chen, Z. E., Merrick, L., Mortele, K. J., Hoff, F. L., Hammond, N. A., Yaghmai, V., & Nikolaidis, P. (2011) · RadioGraphics · doi:10.1148/rg.313105174 · Cited by 175
Diffusion-weighted magnetic resonance imaging of pancreas tumours
Kartalis, N., Lindholm, T. L., Aspelin, P., Permert, J., & Albiin, N. (2009) · European Radiology · doi:10.1007/s00330-009-1384-8 · Cited by 171
Muraoka, N., Uematsu, H., Kimura, H., Imamura, Y., Fujiwara, Y., Murakami, M., Yamaguchi, A., & Itoh, H. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21340 · Cited by 163
Diffusion-weighed MR imaging of pancreatic carcinoma
Matsuki, M., Inada, Y., Nakai, G., Tatsugami, F., Tanikake, M., Narabayashi, I., Masuda, D., Arisaka, Y., Takaori, K., & Tanigawa, N. (2007) · Abdominal Imaging · doi:10.1007/s00261-007-9192-6 · Cited by 148
Klau, M., Lemke, A., Grünberg, K., Simon, D., Re, T. J., Wente, M. N., Laun, F. B., Kauczor, H., Delorme, S., Grenacher, L., et al. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181fb3bf2 · Cited by 142 · cited 2×
“Furthermore, our results are similar to those of a previous study by Klauss et al (23), which demonstrated that the perfusion fraction f proved to be a superior DW imaging-derived parameter for differentiation of mass-forming pancreatitis and pancreatic carcinoma.”
BackgroundResultSmall (≤3 cm) Solid Pseudopapillary Tumors of the Pancreas at Multiphasic Multidetector CT
Baek, J. H., Lee, J. M., Kim, S. H., Kim, S. J., Kim, S. H., Lee, J. Y., Han, J. K., & Choi, B. (2010) · Radiology · doi:10.1148/radiol.10092089 · Cited by 118
Self-citationCancer Statistics in Korea: Incidence, Mortality and Survival in 2005
Jung, K., Won, Y., Park, S., Kong, H., Sung, J., Shin, H., Park, E., & Lee, J. S. (2009) · Journal of Korean Medical Science · doi:10.3346/jkms.2009.24.6.995 · Cited by 116 · cited 1×
“Neuroendocrine tumors (NETs) are the second most common malignant neoplasm of the pancreas (5) and have been shown to be a common cause of gastrointestinal cancer–related mortality (6,7).”
BackgroundSelf-citationHelical CT of Islet Cell Tumors of the Pancreas: Typical and Atypical Manifestations
Sheth, S., Hruban, R. H., & Fishman, E. K. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.3.1790725 · Cited by 104 · cited 1×
“Yet, atypical enhancement patterns of PACs or NETs are not rare at dynamic MR imaging or CT (28,29) because of tumor size, degree of differentiation, and PAC from NP, CP, and NETs.”
BackgroundAn Algorithmic Approach to the Diagnosis of Pancreatic Neoplasms
Klimstra, D. S., Pitman, M. B., & Hruban, R. H. (2009) · Archives of Pathology & Laboratory Medicine · doi:10.5858/133.3.454 · Cited by 94
Diffusion-Weighted Imaging in the Differential Diagnosis of Cystic Lesions of the Pancreas
İnan, N., Arslan, A., Akansel, G., Yonca Akgoz, A. N. I. K., & Demırcı, A. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.3754 · Cited by 85
Invasive cancer and survival of intraductal papillary mucinous tumors of the pancreas
Raimondo, M. (2002) · The American Journal of Gastroenterology · doi:10.1016/s0002-9270(02)04380-0 · Cited by 81
Pancreatic adenocarcinoma versus chronic pancreatitis: differentiation with triple-phase helical CT
Yamada, Y., Mori, H., Matsumoto, S., Kiyosue, H., Hori, Y., & Hongo, N. (2009) · Abdominal Imaging · doi:10.1007/s00261-009-9579-7 · Cited by 76
Re, T. J., Lemke, A., Klauß, M., Laun, F. B., Simon, D., Grünberg, K., Delorme, S., Grenacher, L., Manfredi, R. M., Mucelli, R. P., et al. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22931 · Cited by 46 · cited 1×
“Consistent with the present findings, in previous studies, Lemke et al (22) and Re et al (27) reported that the f value in pancreatic cancer was markedly reduced when compared with healthy pancreatic tissue.”
Result
Cited by
Clinical intravoxel incoherent motion and diffusion MR imaging: Past, present, and future
Iima, M., & Le Bihan, D. (2016) · Radiology · doi:10.1148/radiol.2015150244 · Cited by 498
Diffusion‐weighted imaging outside the brain: Consensus statement from an ISMRM‐sponsored workshop
Taouli, B., Beer, A. J., Chenevert, T., Collins, D., Lehman, C., Matos, C., Padhani, A. R., Rosenkrantz, A. B., Shukla‐Dave, A., Sigmund, E., et al. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25196 · Cited by 175
“PF/f extracted from the IVIM technique has a promising role for differentiation of pancreatic adenocarcinoma from mass-forming pancreatitis.(70) However, this strategy is not easy to implement in the clinic because of the long acquisition time and postprocessing challenges.”
Metadata
- Authors
- Kang, K. M., Lee, J. M., Yoon, J. H., Kiefer, B., Han, J. K., & Choi, B. I.
- Venue
- Radiology
- Published
- 2014-02
- Volume
- 270
- Issue
- 2
- Pages
- 444-453
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2162305044
- Cited by
- 162
- References
- 30
- FWCI
- 13.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.