CT Perfusion of the Liver: Principles and Applications in Oncology
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
With the introduction of molecularly targeted chemotherapeutics, there is an increasing need for defining new response criteria for therapeutic success because use of morphologic imaging alone may not fully assess tumor response. Computed tomographic (CT) perfusion imaging of the liver provides functional information about the microcirculation of normal parenchyma and focal liver lesions and is a promising technique for assessing the efficacy of various anticancer treatments. CT perfusion also shows promising results for diagnosing primary or metastatic tumors, for predicting early response to anticancer treatments, and for monitoring tumor recurrence after therapy. Many of the limitations of early CT perfusion studies performed in the liver, such as limited coverage, motion artifacts, and high radiation dose of CT, are being addressed by recent technical advances. These include a wide area detector with or without volumetric spiral or shuttle modes, motion correction algorithms, and new CT reconstruction technologies such as iterative algorithms. Although several issues related to perfusion imaging-such as paucity of large multicenter trials, limited accessibility of perfusion software, and lack of standardization in methods-remain unsolved, CT perfusion has now reached technical maturity, allowing for its use in assessing tumor vascularity in larger-scale prospective clinical trials. In this review, basic principles, current acquisition protocols, and pharmacokinetic models used for CT perfusion imaging of the liver are described. Various oncologic applications of CT perfusion of the liver are discussed and current challenges, as well as possible solutions, for CT perfusion are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1)
Eisenhauer, E. A., Therasse, P., Bogaerts, J., Schwartz, L. H., Sargent, D., Ford, R., Dancey, J., Arbuck, S., Gwyther, S., Mooney, M., et al. (2009) · European Journal of Cancer · doi:10.1016/j.ejca.2008.10.026 · Cited by 29,534 · cited 1×
“CT perfusion, the measurement of blood flow characteristics through dynamic CT acquisitions following intravenous administration of contrast agents, can easily be integrated into routine CT imaging Treatment effects of conventional chemotherapeutic agents are assessed after three to four cycles of chemotherapy (after…”
Mazzaferro, V., Regalia, E., Doci, R., Andreola, S., Pulvirenti, A., Bozzetti, F., Montalto, F., Ammatuna, M., Morabito, A., & Gennari, L. (1996) · New England Journal of Medicine · doi:10.1056/nejm199603143341104 · Cited by 7,186 · cited 1×
“For example, the 4-year survival rate in patients with cirrhosis and HCC who met liver transplantation criteria was 85% among patients who underwent liver transplantation (65), whereas the prognosis of patients not eligible for transplantation owing to advanced, symptomatic HCC was dismal, with a 5-year survival rate…”
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Modified RECIST (mRECIST) Assessment for Hepatocellular Carcinoma
Lencioni, R., & Llovet, J. (2010) · Seminars in Liver Disease · doi:10.1055/s-0030-1247132 · Cited by 4,329 · cited 1×
“CT perfusion, the measurement of blood flow characteristics through dynamic CT acquisitions following intravenous administration of contrast agents, can easily be integrated into routine CT imaging Treatment effects of conventional chemotherapeutic agents are assessed after three to four cycles of chemotherapy (after…”
Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data
Patlak, C. S., Blasberg, R. G., & Fenstermacher, J. D. (1983) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1983.1 · Cited by 3,567 · cited 1×
“example of a compartment model is the Patlak model (48), in which only blood volume and blood flow extraction product, which is a product of blood flow and contrast agent extraction fraction, can be calculated.”
Rising Incidence of Hepatocellular Carcinoma in the United States
El-Serag, H. B., & Mason, A. C. (1999) · New England Journal of Medicine · doi:10.1056/nejm199903113401001 · Cited by 2,853
Willett, C. G., Boucher, Y., di Tomaso, E., Duda, D. G., Munn, L. L., Tong, R. T., Chung, D. C., Sahani, D. V., Kalva, S. P., Kozin, S. V., et al. (2004) · Nature Medicine · doi:10.1038/nm988 · Cited by 1,966 · cited 1×
“Existing imaging techniques such as fluorodeoxyglucose (FDG) PET, that are not directed at the vascular system, also may be inappropriate because antiangiogenic drugs may induce uncoupling of tumor perfusion and other aspects of tumor physiology such as glucose metabolism (82,83) and because FDG PET there is little cl…”
Weissleder, R., & Mahmood, U. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma19316 · Cited by 1,315
Deformable templates using large deformation kinematics
Christensen, G. E., Rabbitt, R. D., & Miller, M. I. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.536892 · Cited by 1,142
Haematogenous metastastic patterns in colonic carcinoma: An analysis of 1541 necropsies
Weiss, L., Grundmann, E., Torhorst, J., Hartveit, F., Moberg, I., Eder, M., Fenoglio‐Preiser, C. M., Napier, J., Horne, C. H. W., Lopez, M. J., et al. (1986) · The Journal of Pathology · doi:10.1002/path.1711500308 · Cited by 655 · cited 1×
“The liver is the second most common site of metastatic disease after lymph node metastases and the most common metastatic site in patients with colorectal cancer (1,2).”
Metadata
- Authors
- Kim, S. H., Kamaya, A., & Willmann, J. K.
- Venue
- Radiology
- Published
- 2014-08
- Volume
- 272
- Issue
- 2
- Pages
- 322-344
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2114960288
- Cited by
- 200
- References
- 63
- FWCI
- 11.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CT Perfusion of the Liver: Principles and Applications in Oncology. https://app.cochat.ai/papers/10.1148/radiol.14130091
- The paper
- Kim, S. H., Kamaya, A., & Willmann, J. K. (2014). CT Perfusion of the Liver: Principles and Applications in Oncology. Radiology. https://doi.org/10.1148/radiol.14130091
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.