Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 264

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Fractional Flow Reserve Computed from Noninvasive CT Angiography Data: Diagnostic Performance of an On-Site Clinician-operated Computational Fluid Dynamics Algorithm

Coenen, Adriaan, Lubbers, Marisa M., Kurata, Akira, Kono, Atsushi, Dedic, Admir, Chelu, Raluca G., Dijkshoorn, Marcel L., Gijsen, Frank J., Ouhlous, Mohamed, van Geuns, Robert-Jan M., Nieman, Koen·2015·Radiology

Abstract

PURPOSE: To validate an on-site algorithm for computation of fractional flow reserve (FFR) from coronary computed tomographic (CT) angiography data against invasively measured FFR and to test its diagnostic performance as compared with that of coronary CT angiography. MATERIALS AND METHODS: The institutional review board provided a waiver for this retrospective study. From coronary CT angiography data in 106 patients, FFR was computed at a local workstation by using a computational fluid dynamics algorithm. Invasive FFR measurement was performed in 189 vessels (80 of which had an FFR ≤ 0.80); these measurements were regarded as the reference standard. The diagnostic characteristics of coronary CT angiography-derived computational FFR, coronary CT angiography, and quantitative coronary angiography were evaluated against those of invasively measured FFR by using C statistics. Sensitivity and specificity were compared by using a two-sided McNemar test. RESULTS: For computational FFR, sensitivity was 87.5% (95% confidence interval [CI]: 78.2%, 93.8%), specificity was 65.1% (95% CI: 55.4%, 74.0%), and accuracy was 74.6% (95% CI: 68.4%, 80.8%), as compared with the finding of lumen stenosis of 50% or greater at coronary CT angiography, for which sensitivity was 81.3% (95% CI: 71.0%, 89.1%), specificity was 37.6% (95% CI: 28.5%, 47.4%), and accuracy was 56.1% (95% CI: 49.0%, 63.2%). C statistics revealed a larger area under the receiver operating characteristic curve (AUC) for computational FFR (AUC, 0.83) than for coronary CT angiography (AUC, 0.64). For vessels with intermediate (25%-69%) stenosis, the sensitivity of computational FFR was 87.3% (95% CI: 76.5%, 94.3%) and the specificity was 59.3% (95% CI: 47.8%, 70.1%). CONCLUSION: With use of a reduced-order algorithm, computation of the FFR from coronary CT angiography data can be performed locally, at a regular workstation. The diagnostic accuracy of coronary CT angiography-derived computational FFR for the detection of functionally important coronary artery disease (CAD) was good and was incremental to that of coronary CT angiography within a population with a high prevalence of CAD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.14140992

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 264

Metadata

Authors
Coenen, A., Lubbers, M. M., Kurata, A., Kono, A., Dedic, A., Chelu, R. G., Dijkshoorn, M. L., Gijsen, F. J., Ouhlous, M., van Geuns, R.-J. M., & Nieman, K.
Venue
Radiology
Published
2015-03
Volume
274
Issue
3
Pages
674-683
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2141408670
Cited by
264
References
29
FWCI
19.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fractional Flow Reserve Computed from Noninvasive CT Angiography Data: Diagnostic Performance of an On-Site Clinician-operated Computational Fluid Dynamics Algorithm. https://app.cochat.ai/papers/10.1148/radiol.14140992
The paper
Coenen, A., Lubbers, M. M., Kurata, A., Kono, A., Dedic, A., Chelu, R. G., Dijkshoorn, M. L., Gijsen, F. J., Ouhlous, M., van Geuns, R.-J. M., & Nieman, K. (2015). Fractional Flow Reserve Computed from Noninvasive CT Angiography Data: Diagnostic Performance of an On-Site Clinician-operated Computational Fluid Dynamics Algorithm. Radiology. https://doi.org/10.1148/radiol.14140992

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.