CoChat

Accelerating MR Imaging Liver Steatosis Measurement Using Combined Compressed Sensing and Parallel Imaging: A Quantitative Evaluation

Open access
Mann, Louis W., Higgins, David M., Peters, Carl N., Cassidy, Sophie, Hodson, Kenneth K., Coombs, Anna, Taylor, Roy, Hollingsworth, Kieren G. · 2016 · Radiology
Cited by 44

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

PURPOSE: To determine the limits of agreement of hepatic fat fraction and R2* relaxation rate quantified with accelerated magnetic resonance (MR) imaging reconstructed with combined compressed sensing and parallel imaging compared with conventional fully sampled acquisitions. MATERIALS AND METHODS: Eleven subjects with type 2 diabetes and a healthy control subject were recruited with the approval of the Newcastle and North Tyneside 2 ethics committee and written consent. Undersampled data at ratios of 2.6×, 2.9×, 3.8×, and 4.8× were prospectively acquired in addition to fully sampled data by using five gradient echoes per repetition time at 3.0 T. Fat fraction maps were calculated by using combined compressed sensing and parallel imaging (CS-PI) reconstruction and Bland-Altman analysis performed to assess bias and 95% limits of agreement. Inter- and intrarater analysis was performed for quantitative fat fraction and R2* relaxation rate, and image quality was assessed with a four-point scale by two independent observers. RESULTS: The fat fractions from the accelerated acquisitions had 95% limits of agreement of 1.2%, 1.2%, 1.1%, and 1.5%, respectively, with no bias. When compared with the intra- and interrater 95% limits of agreement (0.7% and 0.8%), acceleration of up to 3.8× did not greatly degrade the fat fraction measurements. No or minimal artifact was detected at 2.6× and 2.9× accelerations, moderate artifact was detected at 3.8× acceleration, and substantial artifact was detected at 4.8× acceleration. CONCLUSION: Prospective undersampling and CS-PI reconstruction of liver fat fractions can be used to accelerate liver fat fraction measurements. The fat fractions and image quality produced were acceptable up to a factor of 3.8×, thereby shortening the required breath-hold duration from 17.7 seconds to 4.7 seconds.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2015150320

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 44

Metadata

Authors
Mann, L. W., Higgins, D. M., Peters, C. N., Cassidy, S., Hodson, K. K., Coombs, A., Taylor, R., & Hollingsworth, K. G.
Venue
Radiology
Published
2016-01
Volume
278
Issue
1
Pages
247-256
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2110003651
Cited by
44
References
5
FWCI
4.68
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accelerating MR Imaging Liver Steatosis Measurement Using Combined Compressed Sensing and Parallel Imaging: A Quantitative Evaluation. https://app.cochat.ai/papers/10.1148/radiol.2015150320
The paper
Mann, L. W., Higgins, D. M., Peters, C. N., Cassidy, S., Hodson, K. K., Coombs, A., Taylor, R., & Hollingsworth, K. G. (2016). Accelerating MR Imaging Liver Steatosis Measurement Using Combined Compressed Sensing and Parallel Imaging: A Quantitative Evaluation. Radiology. https://doi.org/10.1148/radiol.2015150320

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.