CoChat

Effect of Human-AI Interaction on Detection of Malignant Lung Nodules on Chest Radiographs

Lee, Jong Hyuk, Hong, Hyunsook, Nam, Gunhee, Hwang, Eui Jin, Park, Chang Min · 2023 · Radiology
Cited by 53

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

Background The factors affecting radiologists' diagnostic determinations in artificial intelligence (AI)-assisted image reading remain underexplored. Purpose To assess how AI diagnostic performance and reader characteristics influence detection of malignant lung nodules during AI-assisted reading of chest radiographs. Materials and Methods This retrospective study consisted of two reading sessions from April 2021 to June 2021. Based on the first session without AI assistance, 30 readers were assigned into two groups with equivalent areas under the free-response receiver operating characteristic curve (AUFROCs). In the second session, each group reinterpreted radiographs assisted by either a high or low accuracy AI model (blinded to the fact that two different AI models were used). Reader performance for detecting lung cancer and reader susceptibility (changing the original reading following the AI suggestion) were compared. A generalized linear mixed model was used to identify the factors influencing AI-assisted detection performance, including readers' attitudes and experiences of AI and Grit score. Results Of the 120 chest radiographs assessed, 60 were obtained in patients with lung cancer (mean age, 67 years ± 12 [SD]; 32 male; 63 cancers) and 60 in controls (mean age, 67 years ± 12; 36 male). Readers included 20 thoracic radiologists (5-18 years of experience) and 10 radiology residents (2-3 years of experience). Use of the high accuracy AI model improved readers' detection performance to a greater extent than use of the low accuracy AI model (area under the receiver operating characteristic curve, 0.77 to 0.82 vs 0.75 to 0.75; AUFROC, 0.71 to 0.79 vs 0.7 to 0.72). Readers who used the high accuracy AI showed a higher susceptibility (67%, 224 of 334 cases) to changing their diagnosis based on the AI suggestions than those using the low accuracy AI (59%, 229 of 386 cases). Accurate readings at the first session, correct AI suggestions, high accuracy Al, and diagnostic difficulty were associated with accurate AI-assisted readings, but readers' characteristics were not. Conclusion An AI model with high diagnostic accuracy led to improved performance of radiologists in detecting lung cancer on chest radiographs and increased radiologists' susceptibility to AI suggestions. © RSNA, 2023

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.222976

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 53

Metadata

Authors
Lee, J. H., Hong, H., Nam, G., Hwang, E. J., & Park, C. M.
Venue
Radiology
Published
2023-06-01
Volume
307
Issue
5
Pages
e222976-e222976
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W4382182556
Cited by
53
References
22
FWCI
4.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.