Dynamic MR Imaging of the Pelvic Floor Performed with Patient Sitting in an Open-Magnet Unit versus with Patient Supine in a Closed-Magnet Unit

Bertschinger, Katharina M., Hetzer, Frank H., Roos, Justus E., Treiber, Karl, Marincek, Borut, Hilfiker, Paul R. · 2002 · Radiology

Abstract

PURPOSE: To compare open-magnet magnetic resonance (MR) imaging performed with the patient sitting with dynamic closed-magnet MR imaging of the pelvic floor performed with the patient supine. MATERIALS AND METHODS: Thirty-eight patients underwent dynamic 1.5-T closed-magnet pelvic floor MR imaging while in the supine position. Midsagittal T2-weighted single-shot fast spin-echo and T1-weighted multiphase spoiled gradient-recalled-echo (SPGR) MR images were obtained before and after rectal contrast agent administration, respectively, with the patient at rest, straining, and maximally contracting the sphincter. Subsequently, the patient was transferred to an open 0.5-T system. Midsagittal multiphase T1-weighted SPGR MR images were then obtained every 2 seconds with the patient sitting while at rest, maximally contracting the sphincter, straining, and defecating. Images were analyzed with regard to presence of enteroceles, anterior rectoceles, intussusceptions, rectal descents, bladder descents, and vaginal vault descents. RESULTS: All intussusceptions were missed at supine MR imaging. With sitting MR imaging as the reference standard, the sensitivity of supine MR imaging was 79% for depiction of bladder descents. When MR findings were graded and clinically irrelevant MR findings were excluded, sensitivity increased to 100% for depiction of bladder descents and anterior rectoceles and to 96% for depiction of rectal descents. CONCLUSION: Dynamic supine MR imaging performed with a closed-configuration unit before and after rectal contrast agent administration appears to be an alternative to sitting MR defecography performed with an open-configuration unit for diagnosis of clinically relevant pelvic floor abnormalities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2232010665

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 228

Metadata

Authors
Bertschinger, K. M., Hetzer, F. H., Roos, J. E., Treiber, K., Marincek, B., & Hilfiker, P. R.
Venue
Radiology
Published
2002-05
Volume
223
Issue
2
Pages
501-508
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2140598503
Cited by
228
References
0
FWCI
3.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dynamic MR Imaging of the Pelvic Floor Performed with Patient Sitting in an Open-Magnet Unit versus with Patient Supine in a Closed-Magnet Unit. https://app.cochat.ai/papers/10.1148/radiol.2232010665
The paper
Bertschinger, K. M., Hetzer, F. H., Roos, J. E., Treiber, K., Marincek, B., & Hilfiker, P. R. (2002). Dynamic MR Imaging of the Pelvic Floor Performed with Patient Sitting in an Open-Magnet Unit versus with Patient Supine in a Closed-Magnet Unit. Radiology. https://doi.org/10.1148/radiol.2232010665

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.