The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Which MR-derived Perfusion Parameters are the Best Predictors of Infarct Growth in Hyperacute Stroke? Comparative Study between Relative and Quantitative Measurements
Abstract
PURPOSE: To compare predictors of infarct growth in hyperacute stroke from a retrospective review of various relative and quantitative parameters calculated at perfusion-weighted magnetic resonance (MR) imaging performed within 6 hours after ictus. MATERIALS AND METHODS: Fluid-attenuated inversion recovery and diffusion- and perfusion-weighted images were obtained in 66 patients. The initial infarct was delineated on diffusion-weighted images; the hemodynamic disturbance, on apparent mean transit time (MTT) maps; and the final infarct, on follow-up fluid-attenuated inversion recovery images. Relative (without and with deconvolution) and quantitative values of the bolus arrival time, time to peak (TTP), apparent MTT or MTT, cerebral blood volume (CBV), peak height, and cerebral blood flow (CBF) index or CBF were calculated for initial infarct, infarct growth (final minus initial infarct contour), viable hemodynamic disturbance (apparent MTT minus final infarct contour), and contralateral mirror regions. Univariate and multivariate analyses (receiver operating characteristic curves and discriminant analysis) were performed to compare the diagnostic performance of these parameters for predicting infarct growth. RESULTS: At univariate analysis, relative peak height and quantitative CBF were the best predictors of infarct growth; at multivariate analysis, a function of peak height and TTP for relative measurements and CBF alone for quantitative measurements. Quantitative and relative measurements (without or with deconvolution) worked equally well. A combined relative peak height or TTP threshold (<54% or >5.2 seconds, respectively) had a sensitivity of 71% and a specificity of 98%. A quantitative CBF threshold (<35 mL/min/100 g) had a sensitivity of 69% and a specificity of 85%. CONCLUSION: A combination of relative peak height and TTP measurements allowed the best prediction of infarct growth, which obviates more complex quantitative calculation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Plasminogen Activator for Acute Ischemic Stroke
(1995) · New England Journal of Medicine · doi:10.1056/nejm199512143332401 · Cited by 11,654
Thresholds in cerebral ischemia - the ischemic penumbra.
Astrup, J., Siesjö, B. K., & Symon, L. (1981) · Stroke · doi:10.1161/01.str.12.6.723 · Cited by 2,820
Cited by
Wu, O., Østergaard, L., Weisskoff, R. M., Benner, T., Rosen, B. R., & Sorensen, A. G. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10522 · Cited by 604
Comparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Self-citationKidwell, C. S., Alger, J. R., & Saver, J. L. (2003) · Stroke · doi:10.1161/01.str.0000097608.38779.cc · Cited by 473
Kim, M. N., Durduran, T., Frangos, S., Edlow, B. L., Buckley, E. M., Moss, H. E., Zhou, C., Yu, G., Choe, R., Maloney-Wilensky, E., et al. (2010) · Neurocritical Care · doi:10.1007/s12028-009-9305-x · Cited by 306
Law, M., Saindane, A. M., Ge, Y., Babb, J. S., Johnson, G., Mannon, L. J., Herbert, J., & Grossman, R. I. (2004) · Radiology · doi:10.1148/radiol.2313030996 · Cited by 242
Metadata
- Authors
- Grandin, C. B., Duprez, T. P., Smith, A. M., Oppenheim, C., Peeters, A., Robert, A. R., & Cosnard, G.
- Venue
- Radiology
- Published
- 2002-05
- Volume
- 223
- Issue
- 2
- Pages
- 361-370
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2151430135
- Cited by
- 169
- References
- 2
- FWCI
- 11.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.