The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Breath-hold FLASH and FISP Cardiovascular MR Imaging: Left Ventricular Volume Differences and Reproducibility
Abstract
PURPOSE: To compare fast imaging with steady-state precession (FISP) and fast low-angle shot (FLASH) magnetic resonance acquisitions to quantify left ventricular volumes, mass, and function and to determine if the two techniques are comparable. MATERIALS AND METHODS: Left ventricular volume studies were performed in 10 patients with heart failure and in 10 healthy subjects by using FISP and FLASH imaging. Identical section positions were used for section-by-section contour comparisons. Manual analysis was performed by two experienced observers. The study was repeated on a different day and interobserver and interstudy reproducibility assessed. RESULTS: With FISP, end-diastolic volume was larger (healthy subjects: +18 mL [13%], P <.001; patients: +6 mL [3%], not significant), end-systolic volume larger (healthy subjects: +9 mL [17%], P =.001; patients: +8 mL [6%], P =.001) and left ventricular mass smaller (healthy subjects: -25 g (19%), P <.001; patients: -21 g (11%), P <.001). There were no significant differences in ejection fraction. Both sequences had excellent interstudy and interobserver reproducibility, with statistically better reproducibility for interstudy healthy-subject ejection fraction on FISP images (P =.05). Section-by-section analysis determined that at FISP, endocardial contours were drawn larger and the epicardial contours smaller than on FLASH images. FISP enabled better delineation of epicardial fat from myocardium, of blood-myocardium interface in areas of trabeculation or papillary muscles, and of the atrioventricular ring. CONCLUSION: FISP produces small but significantly higher left ventricular volume measurements, as compared with FLASH imaging. FLASH imaging and FISP have similar reproducibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Bellenger, N. (2000) · European Heart Journal · doi:10.1053/euhj.2000.2011 · Cited by 1,040
Lorenz, C., Walker, E., Morgan, V., Klein, S., & Graham, T. (1999) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976649909080829 · Cited by 717
Self-citationBellenger, N., Davies, L. C., Francis, J., Coats, A., & Pennell, D. (2000) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976640009148691 · Cited by 681
Self-citationSemelka, R. C., Tomei, E., Wagner, S., Mayo, J. R., Kondo, C., Suzuki, J., Caputo, G. R., & Higgins, C. B. (1990) · Radiology · doi:10.1148/radiology.174.3.2305059 · Cited by 393
BOTTINI, P., CARR, A., PRISANT, L., FLICKINGER, F., ALLISON, J., & GOTTDIENER, J. (1995) · American Journal of Hypertension · doi:10.1016/0895-7061(94)00178-e · Cited by 363
Pattynama, P. M., Lamb, H. J., van der Velde, E. A., van der Wall, E. E., & de Roos, A. (1993) · Radiology · doi:10.1148/radiology.187.1.8451425 · Cited by 330
Semelka, R. C., Tomei, E., Wagner, S., Mayo, J., Caputo, G., O'Sullivan, M., Parmley, W. W., Chatterjee, K., Wolfe, C., & Higgins, C. B. (1990) · American Heart Journal · doi:10.1016/s0002-8703(05)80187-5 · Cited by 295
Evaluation of left ventricular volume and mass with breath-hold cine MR imaging.
Sakuma, H., Fujita, N., Foo, T. K., Caputo, G. R., Nelson, S. J., Hartiala, J., Shimakawa, A., & Higgins, C. B. (1993) · Radiology · doi:10.1148/radiology.188.2.8327681 · Cited by 262
Estimation of human myocardial mass with MR imaging.
Katz, J., Milliken, M. C., Stray-Gundersen, J., Buja, L. M., Parkey, R. W., Mitchell, J. H., & Peshock, R. M. (1988) · Radiology · doi:10.1148/radiology.169.2.2971985 · Cited by 259
Cited by
Maceira, A., Prasad, S., Khan, M., & Pennell, D. (2006) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640600572889 · Cited by 847
Self-citationWRITING COMMITTEE MEMBERS, Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181d44a8f · Cited by 821
Flett, A. S., Hasleton, J., Cook, C., Hausenloy, D., Quarta, G., Ariti, C., Muthurangu, V., & Moon, J. C. (2011) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2010.11.015 · Cited by 690
Self-citationHudsmith†, L., Petersen†, S., Francis, J., Robson, M., & Neubauer, S. (2005) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640500295516 · Cited by 627
Self-citationACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance
Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., Manning, W. J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.011 · Cited by 593
Metadata
- Authors
- Moon, J. C. C., Lorenz, C. H., Francis, J. M., Smith, G. C., & Pennell, D. J.
- Venue
- Radiology
- Published
- 2002-06
- Volume
- 223
- Issue
- 3
- Pages
- 789-797
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2037742571
- Cited by
- 294
- References
- 21
- FWCI
- 14.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Breath-hold FLASH and FISP Cardiovascular MR Imaging: Left Ventricular Volume Differences and Reproducibility. https://app.cochat.ai/papers/10.1148/radiol.2233011181
- The paper
- Moon, J. C. C., Lorenz, C. H., Francis, J. M., Smith, G. C., & Pennell, D. J. (2002). Breath-hold FLASH and FISP Cardiovascular MR Imaging: Left Ventricular Volume Differences and Reproducibility. Radiology. https://doi.org/10.1148/radiol.2233011181
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.