Lung Cancer: Performance of Automated Lung Nodule Detection Applied to Cancers Missed in a CT Screening Program
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the performance of a fully automated computerized method for the detection of lung nodules in computed tomographic (CT) scans in the identification of lung cancers that may be missed during visual interpretation. MATERIALS AND METHODS: A database of 38 low-dose CT scans with 50 lung nodules was obtained from a lung cancer screening program. Thirty-eight of the nodules represented biopsy-confirmed lung cancers that had not been reported during initial clinical interpretation. A computer detection method that involved the use of gray-level thresholding techniques to identify three-dimensionally contiguous structures within the lungs was applied to the CT data. Computer-extracted volume was used to determine whether a structure became a nodule candidate. A rule-based scheme and a cascaded automated classifier were applied to the set of nodule candidates to distinguish actual nodules from areas of normal anatomy. Overall performance of the computer detection method was evaluated with free-response receiver operating characteristic (FROC) analysis. RESULTS: At a specific operating point on the FROC curve, the method achieved a sensitivity of 80% (40 of 50 nodules), with an average of 1.0 false-positive detection per section. Missed cancers were detected by the computerized method with a sensitivity of 84% (32 of 38 nodules) and a false-positive rate of 1.0 per section. CONCLUSION: With an automated lung nodule detection method, a large fraction (84%, 32 of 38) of missed cancers in a database of low-dose CT scans were detected correctly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applied Multivariate Statistical Analysis.
Johnson, A. R., & Wichern, D. W. (1988) · Biometrics · doi:10.2307/2531616 · Cited by 11,353
Jemal, A., Thomas, A., Murray, T., & Thun, M. (2002) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.52.1.23 · Cited by 2,917
Early Lung Cancer Action Project: overall design and findings from baseline screening
Henschke, C. I., McCauley, D. I., Yankelevitz, D. F., Naidich, D. P., McGuinness, G., Miettinen, O. S., Libby, D. M., Pasmantier, M. W., Koizumi, J., Altorki, N. K., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(99)06093-6 · Cited by 2,508
ROC Methodology in Radiologic Imaging
METZ, C. E. (1986) · Investigative Radiology · doi:10.1097/00004424-198609000-00009 · Cited by 1,642
Mass screening for lung cancer with mobile spiral computed tomography scanner
Sone, S., Takashima, S., Li, F., Yang, Z., Honda, T., Maruyama, Y., Hasegawa, M., Yamanda, T., Kubo, K., Hanamura, K., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(97)08229-9 · Cited by 931
Self-citationPeripheral lung cancer: screening and detection with low-dose spiral CT versus radiography.
Kaneko, M., Eguchi, K., Ohmatsu, H., Kakinuma, R., Naruke, T., Suemasu, K., & Moriyama, N. (1996) · Radiology · doi:10.1148/radiology.201.3.8939234 · Cited by 831
Metz, C. E., Herman, B. A., & Shen, J.-H. (1998) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19980515)17:9<1033::aid-sim784>3.0.co;2-z · Cited by 793
Sone, S., Li, F., Yang, Z.-G., Honda, T., Maruyama, Y., Takashima, S., Hasegawa, M., Kawakami, S., Kubo, K., Haniuda, M., et al. (2001) · British Journal of Cancer · doi:10.1054/bjoc.2000.1531 · Cited by 495
Self-citationVisual Scanning, Pattern Recognition and Decision-making in Pulmonary Nodule Detection
Kundel, H. L., Nodine, C. F., & Carmody, D. (1978) · Investigative Radiology · doi:10.1097/00004424-197805000-00001 · Cited by 448
Computerized Detection of Pulmonary Nodules on CT Scans
Armato, S. G., Giger, M. L., Moran, C. J., Blackburn, J. T., Doi, K., & MacMahon, H. (1999) · Radiographics · doi:10.1148/radiographics.19.5.g99se181303 · Cited by 380
Self-citation
Cited by
Ardila, D., Kiraly, A. P., Bharadwaj, S., Choi, B., Reicher, J. J., Peng, L., Tse, D., Etemadi, M., Ye, W., Corrado, G., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0447-x · Cited by 2,167
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
Self-citationBreast Cancer, Version 4.2017, NCCN Clinical Practice Guidelines in Oncology
Gradishar, W. J., Anderson, B. O., Balassanian, R., Blair, S. L., Burstein, H. J., Cyr, A., Elias, A. D., Farrar, W. B., Forero, A., Giordano, S. H., et al. (2018) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2018.0012 · Cited by 1,609
Lung Cancer Screening, Version 3.2018, NCCN Clinical Practice Guidelines in Oncology
Wood, D. E., Kazerooni, E. A., Baum, S. L., Eapen, G. A., Ettinger, D. S., Hou, L., Jackman, D. M., Klippenstein, D., Kumar, R., Lackner, R. P., et al. (2018) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2018.0020 · Cited by 611
Computer analysis of computed tomography scans of the lung: a survey
Sluimer, I., Schilham, A., Prokop, M., & van Ginneken, B. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.862753 · Cited by 556
Ganeshan, B., Panayiotou, E., Burnand, K., Dizdarevic, S., & Miles, K. (2012) · European Radiology · doi:10.1007/s00330-011-2319-8 · Cited by 505
Current status and future potential of computer-aided diagnosis in medical imaging
Doi, K. (2005) · The British Journal of Radiology · doi:10.1259/bjr/82933343 · Cited by 444
Self-citationQuantifying tumour heterogeneity with CT
Ganeshan, B., & Miles, K. A. (2013) · Cancer Imaging · doi:10.1102/1470-7330.2013.0015 · Cited by 395
Ganeshan, B., Abaleke, S., Young, R. C. D., Chatwin, C. R., & Miles, K. A. (2010) · Cancer Imaging · doi:10.1102/1470-7330.2010.0021 · Cited by 324
Giger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311
Self-citationMeasures of Response: RECIST, WHO, and New Alternatives
Jaffe, C. C. (2006) · Journal of Clinical Oncology · doi:10.1200/jco.2006.06.5599 · Cited by 302
van Ginneken, B., Armato, S. G., de Hoop, B., van Amelsvoort-van de Vorst, S., Duindam, T., Niemeijer, M., Murphy, K., Schilham, A., Retico, A., Fantacci, M. E., et al. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.05.005 · Cited by 298
Self-citationDoi, K. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r02 · Cited by 290
Self-citationComputer-Aided Diagnosis Systems for Lung Cancer: Challenges and Methodologies
El-Baz, A., Beache, G. M., Gimel'farb, G., Suzuki, K., Okada, K., Elnakib, A., Soliman, A., & Abdollahi, B. (2013) · International Journal of Biomedical Imaging · doi:10.1155/2013/942353 · Cited by 277
Machine Learning for Lung Cancer Diagnosis, Treatment, and Prognosis
Li, Y., Wu, X., Yang, P., Jiang, G., & Luo, Y. (2022) · Genomics, Proteomics & Bioinformatics · doi:10.1016/j.gpb.2022.11.003 · Cited by 263
Suzuki, K., Armato, S. G., Li, F., Sone, S., & Doi, K. (2003) · Medical Physics · doi:10.1118/1.1580485 · Cited by 262
Self-citationRubin, G. D., Lyo, J. K., Paik, D. S., Sherbondy, A. J., Chow, L. C., Leung, A. N., Mindelzun, R., Schraedley-Desmond, P. K., Zinck, S. E., Naidich, D. P., et al. (2005) · Radiology · doi:10.1148/radiol.2341040589 · Cited by 259
Computer-Aided Diagnosis and Artificial Intelligence in Clinical Imaging
Shiraishi, J., Li, Q., Appelbaum, D., & Doi, K. (2011) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2011.06.004 · Cited by 206
Self-citationComputed Tomography: Revolutionizing the Practice of Medicine for 40 Years
Rubin, G. D. (2014) · Radiology · doi:10.1148/radiol.14141356 · Cited by 197
Low-Dose CT Screening for Lung Cancer: Computer-aided Detection of Missed Lung Cancers
Liang, M., Tang, W., Xu, D. M., Jirapatnakul, A. C., Reeves, A. P., Henschke, C. I., & Yankelevitz, D. (2016) · Radiology · doi:10.1148/radiol.2016150063 · Cited by 154
Machine Learning Applications in Lung Cancer Diagnosis, Treatment and Prognosis
Li, Y., Wu, X., Yang, P., Jiang, G., & Luo, Y. (2022) · arXiv · doi:10.48550/arxiv.2203.02794 · Cited by 2
Metadata
- Authors
- Armato, S. G., Li, F., Giger, M. L., MacMahon, H., Sone, S., & Doi, K.
- Venue
- Radiology
- Published
- 2002-12
- Volume
- 225
- Issue
- 3
- Pages
- 685-692
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2054648089
- Cited by
- 280
- References
- 18
- FWCI
- 21.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.