Coronary Artery Anomalies: Assessment with Free-breathing Three-dimensional Coronary MR Angiography
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate a simplified protocol by using free-breathing three-dimensional (3D) coronary magnetic resonance (MR) angiography to determine the anatomy of anomalous coronary arteries, in particular the relationship of the vessels to the aortic root. MATERIALS AND METHODS: Twenty-six patients (18 men, eight women; mean age, 50 years; age range, 18-77 years) who had a history of chest pain, palpitations, or syncope and who were suspected of having coronary artery anomalies were examined with free-breathing MR angiography. Multiple 3D volume slabs were acquired at the level of the sinuses of Valsalva by using diaphragmatic navigators for respiratory artifact suppression. The proximal anatomy of the coronary arteries was determined. RESULTS: Six anomalous circumflex arteries originated from the right sinus of Valsalva and passed behind the aortic root. Six right coronary arteries arose from the left sinus of Valsalva and coursed between the aortic root and the right ventricular outflow tract (RVOT). Nine left coronary arteries arose from the right sinus of Valsalva; seven of nine coursed between the aortic root and the RVOT. Five patients had minor anomalies. Overall, in eight patients with anomalous arteries that coursed between the aortic root and the RVOT, conventional coronary angiography could not be used confidently to identify the proximal course. CONCLUSION: Free-breathing 3D coronary MR angiography can be used to identify the proximal anatomy of anomalous coronary arteries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coronary artery anomalies in 126,595 patients undergoing coronary arteriography
Yamanaka, O., & Hobbs, R. E. (1990) · Catheterization and Cardiovascular Diagnosis · doi:10.1002/ccd.1810210110 · Cited by 2,068
Coronary Magnetic Resonance Angiography for the Detection of Coronary Stenoses
Kim, W. Y., Danias, P. G., Stuber, M., Flamm, S. D., Plein, S., Nagel, E., Langerak, S. E., Weber, O. M., Pedersen, E. M., Schmidt, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010866 · Cited by 903
CHEITLIN, M. D., DE CASTRO, C. M., & MCALLISTER, H. A. (1974) · Circulation · doi:10.1161/01.cir.50.4.780 · Cited by 772
Click, R. L., Holmes, D. R., Vlietstra, R. E., Kosinski, A. S., & Kronmal, R. A. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90588-3 · Cited by 410
Post, J. C., van Rossum, A. C., Bronzwaer, J. G. F., de Cock, C. C., Hofman, M. B. M., Valk, J., & Visser, C. A. (1995) · Circulation · doi:10.1161/01.cir.92.11.3163 · Cited by 339
Roberts, W. C., Siegel, R. J., & Zipes, D. P. (1982) · The American Journal of Cardiology · doi:10.1016/0002-9149(82)91970-1 · Cited by 339
Kragel, A. H., & Roberts, W. C. (1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)91220-9 · Cited by 334
Barth, C. W., & Roberts, W. C. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80507-1 · Cited by 188
The role of transesophageal echocardiography in identifying anomalous coronary arteries.
Fernandes, F. C., Alam, M. J., Smith, S. T., & Khaja, F. (1993) · Circulation · doi:10.1161/01.cir.88.6.2532 · Cited by 146
Angiographic identification of primary coronary anomalies causing impaired myocardial perfusion
Donaldson, R. M., Raphael, M. J., Radley-Smith, R., Yacoub, M. H., & Ross, D. N. (1983) · Catheterization and Cardiovascular Diagnosis · doi:10.1002/ccd.1810090303 · Cited by 88
Cited by
WRITING COMMITTEE MEMBERS, Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181d44a8f · Cited by 821
Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?
PENNELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.040 · Cited by 747
Self-citationACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance
Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., Manning, W. J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.011 · Cited by 593
Bluemke, D. A., Achenbach, S., Budoff, M., Gerber, T. C., Gersh, B., Hillis, L. D., Hundley, W. G., Manning, W. J., Printz, B. F., Stuber, M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.189695 · Cited by 461
Kilner, P. J., Geva, T., Kaemmerer, H., Trindade, P. T., Schwitter, J., & Webb, G. D. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp586 · Cited by 429
Coronary artery anomalies overview: The normal and the abnormal
Villa, A. D., Sammut, E., Nair, A., Rajani, R., Bonamini, R., & Chiribiri, A. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i6.537 · Cited by 375
Schoepf, U. J., Becker, C. R., Ohnesorge, B. M., & Yucel, E. K. (2004) · Radiology · doi:10.1148/radiol.2321030636 · Cited by 356
Clinical Indications for Cardiovascular Magnetic Resonance (CMR): Consensus Panel Report #
Pennell, D., Sechtem, U., Higgins, C., Manning, W., Pohost, G., Rademakers, F., van Rossum, A., Shaw, L., & Kent Yucel, E. (2004) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-200038581 · Cited by 274
Self-citationSchmitt, R., Froehner, S., Brunn, J., Wagner, M., Brunner, H., Cherevatyy, O., Gietzen, F., Christopoulos, G., Kerber, S., & Fellner, F. (2005) · European Radiology · doi:10.1007/s00330-005-2707-z · Cited by 247
“In small collectives, electron beam CT (EBCT) [22, 23] and magnetic resonance angiography (MRA) [15, 19, 24, 25 ] were judged as promising diagnostic tools in the assessment of anomalous coronary arteries and fistulas.”
MethodInfluentialIdentifying, Characterizing, and Classifying Congenital Anomalies of the Coronary Arteries
Shriki, J. E., Shinbane, J. S., Rashid, M. A., Hindoyan, A., Withey, J. G., DeFrance, A., Cunningham, M., Oliveira, G. R., Warren, B. H., & Wilcox, A. (2012) · RadioGraphics · doi:10.1148/rg.322115097 · Cited by 196
Coronary CT versus MR angiography: the role of MR angiography
Sakuma, H. (2011) · Radiology · doi:10.1148/radiol.10100116 · Cited by 73
da Luz, P. L., Bertini, P. J., & Favarato, D. (2005) · Clinics · doi:10.1590/s1807-59322005000500011 · Cited by 13
Metadata
- Authors
- Bunce, N. H., Lorenz, C. H., Keegan, J., Lesser, J., Reyes, E. M., Firmin, D. N., & Pennell, D. J.
- Venue
- Radiology
- Published
- 2003-04
- Volume
- 227
- Issue
- 1
- Pages
- 201-208
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2097730296
- Cited by
- 212
- References
- 10
- FWCI
- 13.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.