The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Effects of Nonionic Intravenous Contrast Agents at PET/CT Imaging: Phantom and Canine Studies
Abstract
Purpose To investigate the effects of intravenous contrast agents on quantitative values obtained with a combined positron emission tomographic (PET) and computed tomographic (CT) scanner by using several phantoms and a dog. Materials and methods Fluorine 18 fluorodeoxyglucose (FDG) was mixed with different concentrations of contrast agent with the same syringe (phantom 1), and the phantom was scanned. After image reconstruction with various attenuation maps, radioactivity concentrations were compared. Then, FDG solutions with (phantom 2) or surrounded by (phantom 3) various concentrations of contrast agent were scanned repeatedly, and radioactivity concentration was compared. Finally, PET and CT with and without contrast agent were performed in a dog. PET images were reconstructed by using different attenuation maps, and radioactivity concentrations were compared. The radioactivity concentration on germanium 68 (68Ge)-based corrected images was regarded as standard, and percentage bias, defined as difference divided by measured activity of 68Ge-based corrected images, was assessed. The relationship between the concentration of contrast agent and the percentage bias was assessed with the Pearson coefficient r, and the significance of correlations was evaluated with the Fisher z test. Results All phantom studies demonstrated that presence of a contrast agent resulted in overestimation of emission data. CT numbers showed a strong positive correlation with the percentage bias in…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, in organs with a particularly high concentration of the contrast agent (e.g., the liver, kidney, or blood vessels), these deviations can be higher [116,120,121].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [120]
Citations
Cites
A combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,655
Hamacher, K., Coenen, H. H., & Stöcklin, G. (1986) · PubMed · Cited by 1,368
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., KESSLER, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 883
PET-CT image co-registration in the thorax: influence of respiration
Goerres, G. W., Kamel, E. M., Heidelberg, T.-N. H., Schwitter, M. R., Burger, C., & von Schulthess, G. K. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-001-0710-4 · Cited by 332
Yamashita, Y., Komohara, Y., Takahashi, M., Uchida, M., Hayabuchi, N., Shimizu, T., & Narabayashi, I. (2000) · Radiology · doi:10.1148/radiology.216.3.r00se26718 · Cited by 250
Combined PET/CT Imaging in Oncology Impact on Patient Management
Kluetz, P. G. (2000) · Clinical Positron Imaging · doi:10.1016/s1095-0397(01)00055-3 · Cited by 224
Image Analysis in Patients with Cancer Studied with a Combined PET and CT Scanner
Charron, M., Beyer, T., Bohnen, N. N., Kinahan, P. E., Dachille, M., Jerin, J., Nutt, R., Meltzer, C. C., Villemagne, V. L., & TOWNSEND, D. W. (2000) · Clinical Nuclear Medicine · doi:10.1097/00003072-200011000-00010 · Cited by 169
Nakamoto, Y., Osman, M., Cohade, C., Marshall, L. T., Links, J. M., Kohlmyer, S. G., & Wahl, R. L. (2002) · PubMed · Cited by 161
Self-citationEffect of Injection Rate of Contrast Medium on Pancreatic and Hepatic Helical CT
TUBLIN, M. E., Tessler, F. N., Cheng, S. L., Peters, T. L., & McGovern, P. C. (1999) · Radiology · doi:10.1148/radiology.210.1.r99ja2197 · Cited by 135
Research works printed but not linked: 1
- Delbeke D.Oncological applications of FDG PET imaging.J Nucl Med1999; 40:1706-1715.
Cited by
Sorted by citations
PET versus SPECT: strengths, limitations and challenges
Rahmim, A., & Zaidi, H. (2008) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e3282f3a515 · Cited by 843
Martínez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R. A., Chefd’hotel, C., Ziegler, S. I., Navab, N., Schwaiger, M., & Nekolla, S. G. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054726 · Cited by 712
Head and Neck Malignancy: Is PET/CT More Accurate than PET or CT Alone?
Branstetter, B. F., Blodgett, T. M., Zimmer, L. A., Snyderman, C. H., Johnson, J. T., Raman, S., & MELTZER, C. C. (2005) · Radiology · doi:10.1148/radiol.2352040134 · Cited by 333
Procedure guideline for tumor imaging with 18F-FDG PET/CT 1.0.
Delbeke, D., Coleman, R. E., Guiberteau, M. J., Brown, M. L., Royal, H. D., Siegel, B. A., Townsend, D. W., Berland, L. L., Parker, J. A., Hubner, K., et al. (2006) · PubMed · Cited by 689
To enhance or not to enhance? 18F-FDG and CT contrast agents in dual-modality 18F-FDG PET/CT.
Antoch, G., Freudenberg, L. S., Beyer, T., Bockisch, A., & Debatin, J. F. (2004) · PubMed · Cited by 236
de Geus‐Oei, L., Vriens, D., van Laarhoven, H. W. M., van der Graaf, W. T. A., & Oyen, W. J. G. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057224 · Cited by 207
PET/CT for the staging and follow-up of patients with malignancies
Poeppel, T. D., Krause, B. J., Heusner, T. A., Boy, C., Bockisch, A., & Antoch, G. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.03.051 · Cited by 197
Unknown Primary Tumors: Detection with Dual-Modality PET/CT—Initial Experience
Gutzeit, A., Antoch, G., Kühl, H., Egelhof, T., Fischer, M., Hauth, E., Goehde, S. C., Bockisch, A., Debatin, J. F., & Freudenberg, L. (2005) · Radiology · doi:10.1148/radiol.2341031554 · Cited by 175
(2005) · PubMed · Cited by 156
Quantifying the Effect of IV Contrast Media on Integrated PET/CT: Clinical Evaluation
Mawlawi, O. R., Erasmus, J. J., Munden, R. F., Pan, T., Knight, A. E., Macapinlac, H. A., Podoloff, D. A., & Chasen, M. H. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.04.1740 · Cited by 143
Clinical Practice in PET/CT for the Management of Head and Neck Squamous Cell Cancer
Goel, R., Moore, W., Sumer, B. D., Khan, S. A., Sher, D. J., & Subramaniam, R. M. (2017) · American Journal of Roentgenology · doi:10.2214/ajr.17.18301 · Cited by 141
Rodríguez‐Vigil, B., León, N. G., Pinilla, I., Hernández‐Maraver, D., Coya, J., Curto, L. M. M., & Madero, R. (2006) · PubMed · Cited by 135
Monitoring cancer treatment with PET/CT: does it make a difference?
Weber, W., & Figlin, R. A. (2007) · PubMed · Cited by 125
Why nearly all PET of abdominal and pelvic cancers will be performed as PET/CT.
Wahl, R. L. (2004) · PubMed · Cited by 127
Self-citationPET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients
Berthelsen, A. K., Holm, S., Loft, A., Klausen, T. L., Andersen, F., & Højgaard, L. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1784-1 · Cited by 151
PET and PET/CT in Pediatric Oncology
Jadvar, H., Connolly, L. P., Fahey, F. H., & Shulkin, B. L. (2007) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2007.04.001 · Cited by 120
Physiology and Pathophysiology of Incidental Findings Detected on FDG-PET Scintigraphy
Liu, Y., Ghesani, N. V., & Zuckier, L. S. (2010) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2010.02.002 · Cited by 112
Coleman, R. E., Delbeke, D., Guiberteau, M. J., Conti, P. S., Royal, H. D., Weinreb, J. C., Siegel, B. A., Federle, M. P., Townsend, D. W., & Berland, L. L. (2005) · PubMed · Cited by 108
Gorospe, L., Raman, S., Echeveste, J., Avril, N. E., Herrero, Y., & ́ndez, S. H. (2005) · Nuclear Medicine Communications · doi:10.1097/01.mnm.0000171779.65284.eb · Cited by 106
Pearls and Pitfalls in Interpretation of Abdominal and Pelvic PET-CT
Blake, M. A., Singh, A. N., Setty, B. N., Slattery, J. M. A., Kalra, M. K., Maher, M. M., Sahani, D. V., Fischman, A. J., & Müeller, P. R. (2006) · Radiographics · doi:10.1148/rg.265055208 · Cited by 105
Procedure Guideline for SPECT/CT Imaging 1.0.
Delbeke, D., Coleman, R. E., Guiberteau, M. J., Brown, M. L., Royal, H. D., Siegel, B. A., Townsend, D. W., Berland, L. L., Parker, J. A., Zubal, G. I., et al. (2006) · PubMed · Cited by 95
Sironi, S., Picchio, M., Landoni, C., Galimberti, S., Signorelli, M., Bettinardi, V., Perego, P., Mangioni, C., Messa, C., & Fazio, F. (2006) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0251-y · Cited by 87
Coleman, R. E., Delbeke, D., Guiberteau, M. J., Conti, P. S., Royal, H. D., Weinreb, J. C., Siegel, B. A., Federle, M. P., Townsend, D. W., & Berland, L. L. (2005) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2005.03.014 · Cited by 85
Indications for PET/CT in the Head and Neck
Agarwal, V., Branstetter, B. F., & Johnson, J. T. (2008) · Otolaryngologic Clinics of North America · doi:10.1016/j.otc.2007.10.005 · Cited by 78
Image-Guided Cancer Therapy Using PET/CT
Yap, J. T., Carney, J., Hall, N. C., & Townsend, D. W. (2004) · The Cancer Journal · doi:10.1097/00130404-200407000-00003 · Cited by 75
Krause, B. J., Beyer, T., Bockisch, A., Delbeke, D., Kotzerke, J., Minkov, V., Reiser, M. F., & Willich, N. (2007) · Nuklearmedizin - NuclearMedicine · doi:10.3413/nukmed-282 · Cited by 70
Kuehl, H., Veit, P., Rosenbaum, S. J., Bockisch, A., & Antoch, G. (2007) · PubMed · Cited by 70
Reinartz, P., Wieres, F.-J., Schneider, W., Schur, A., & Buell, U. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-004-1593-y · Cited by 68
PET/CT today: System and its impact on cancer diagnosis
Tsukamoto, E., & Ochi, S. (2006) · Annals of Nuclear Medicine · doi:10.1007/bf02984642 · Cited by 65
Measuring Response with FDG-PET: Methodological Aspects
Allen-Auerbach, M., & Weber, W. (2009) · The Oncologist · doi:10.1634/theoncologist.2008-0119 · Cited by 64
Kinahan, P. E., Alessio, A. M., & Fessler, J. A. (2006) · Technology in Cancer Research & Treatment · doi:10.1177/153303460600500403 · Cited by 63
Ay, M. R., & Zaidi, H. (2006) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0086-6 · Cited by 63
Attenuation correction for PET/MR: Problems, novel approaches and practical solutions
Martínez-Möller, A., & Nekolla, S. G. (2012) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2012.08.003 · Cited by 62
Strategies for attenuation compensation in neurological PET studies
Zaidi, H., Montandon, M., & Meikle, S. R. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.10.002 · Cited by 54
Advances in Attenuation Correction Techniques in PET
Zaidi, H., Montandon, M., & Alavi, A. A. (2007) · PET Clinics · doi:10.1016/j.cpet.2007.12.002 · Cited by 53
Influences on PET Quantification and Interpretation
Rogasch, J. M. M., Hofheinz, F., van Heek, L., Voltin, C.-A., Boellaard, R., & Kobe, C. (2022) · Diagnostics · doi:10.3390/diagnostics12020451 · Cited by 57
Sharma, P., Kumar, R., Singh, H., Jeph, S., Sharma, D. N., Bal, C. S., & Malhotra, A. (2012) · Clinical Nuclear Medicine · doi:10.1097/rlu.0b013e31824d24fa · Cited by 45
Limitations of CT During PET/CT
Gollub, M. J., Hong, R., Sarasohn, D. M. M., & Akhurst, T. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.043109 · Cited by 44
Savir-Baruch, B., Banks, K. P., McConathy, J., Molchanova-Cook, O. P., Parent, E. E., Takalkar, A. M., Tülchinsky, M., Yu, J. Q., Subramaniam, R. M., & Schuster, D. M. (2018) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000002310 · Cited by 43
PET/CT Imaging Techniques, Considerations, and Artifacts
Mawlawi, O. R., Pan, T., & Macapinlac, H. A. (2006) · Journal of Thoracic Imaging · doi:10.1097/00005382-200605000-00002 · Cited by 41
ACR Practice Parameter for the Performance of Gallium-68 DOTATATE PET/CT for Neuroendocrine Tumors
Subramaniam, R. M., Bradshaw, M. L., Lewis, K. G., Pinho, D. F., Shah, C., & Walker, R. C. (2018) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000002309 · Cited by 37
Current Trends in PET and Combined (PET/CT and PET/MR) Systems Design
Zaidi, H., & Alavi, A. A. (2007) · PET Clinics · doi:10.1016/j.cpet.2007.10.004 · Cited by 36
Zheng, J., Allen, C. J., Serra, S., Vines, D. C., Charron, M., & Jaffray, D. A. (2010) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.378 · Cited by 35
Applications of PET in Liver Imaging
Khandani, A. H., & Wahl, R. L. (2005) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2005.05.008 · Cited by 35
Self-citationPET/CT: fundamental principles.
Seemann, M. D. (2004) · PubMed · Cited by 34
Jadvar, H., Alavi, A. A., Mavi, A., & Shulkin, B. L. (2005) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2004.09.008 · Cited by 32
Ames, J. T., Blodgett, T. M., & MELTZER, C. C. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.04.1282 · Cited by 30
Quantitative Effects of Contrast Enhanced CT Attenuation Correction on PET SUV Measurements
Bunyaviroch, T., Turkington, T. G., Wong, T. Z., Wilson, J. W., Colsher, J. G., & Coleman, R. E. (2007) · Molecular Imaging and Biology · doi:10.1007/s11307-007-0126-z · Cited by 29
Mahmud, M. H., Nordin, A., Saad, F., & Azman, A. Z. F. (2015) · Quantitative Imaging in Medicine and Surgery · doi:10.3978/j.issn.2223-4292.2015.05.02 · Cited by 31
Ahmadian, A., Ay, M. R., Bidgoli, J. H., Sarkar, S., & Zaidi, H. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0756-7 · Cited by 25
Véra, P., Ouvrier, M. J., Hapdey, S., Thillays, M., Pesquet, A. S., Diologent, B., Callonec, F., Hitzel, A., Edet‐Sanson, A., Menard, J. F., et al. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-007-0504-4 · Cited by 24
Azmi, N. H. M., Suppiah, S., Liong, C. W., Noor, N. M., Said, S. M., Hanafi, M. H., Kaewput, C., Saad, F. F. A., & Vinjamuri, S. (2018) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2018.01.019 · Cited by 19
Subramaniam, R. M., Janowitz, W. R., Johnson, G. B., Lodge, M. A., Parisi, M. T., Ferguson, M. R., Hellinger, J. C., Gladish, G. W., & Gupta, N. K. (2017) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000001827 · Cited by 15
Krishnasetty, V., Bonab, A. A., Fischman, A. J., Halpern, E. F., & Aquino, S. L. (2008) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2007.12.007 · Cited by 15
An, Y., Sheen, S. S., Oh, Y. J., Hwang, S. C., & Yoon, J. (2007) · Annals of Nuclear Medicine · doi:10.1007/s12149-007-0066-3 · Cited by 15
Attenuation Correction Strategies in Emission Tomography
Zaidi, H., & Hasegawa, B. H. (2006) · Kluwer Academic Publishers eBooks · doi:10.1007/0-387-25444-7_6 · Cited by 13
Does enhanced CT influence the biological GTV measurement on FDG-PET images?
Véra, P., Modzelewski, R., Hapdey, S., Gouel, P., Tilly, H., Jardin, F., Ruan, S., & Gardin, I. (2013) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2013.03.024 · Cited by 13
Otero, H. J., Yap, J. T., Patak, M. A., Ertürk, Ş. M., Israel, D. A., Johnston, C. J., Sakellis, C., Rybicki, F. J., den Abbeele, A. D. V., & Ros, P. R. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1565 · Cited by 13
Dose optimization: a review of CT imaging for PET attenuation correction
Brady, S. L., & Shulkin, B. L. (2017) · Clinical and Translational Imaging · doi:10.1007/s40336-017-0232-0 · Cited by 13
Voltin, C.-A., Mettler, J., Boellaard, R., Kuhnert, G., Dietlein, M., Borchmann, P., Drzezga, A., & Kobe, C. (2019) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000000956 · Cited by 13
Rehfeld, N., Heismann, B. J., Kupferschläger, J., Aschoff, P., Christ, G., Pfannenberg, A. C., & Pichler, B. J. (2008) · Medical Physics · doi:10.1118/1.2903476 · Cited by 13
PET/CT in lung cancer: Influence of contrast medium on quantitative and clinical assessment
Behrendt, F. F., Temur, Y., Verburg, F. A., Palmowski, M., Krohn, T., Pietsch, H., Kuhl, C. K., & Mottaghy, F. M. (2012) · European Radiology · doi:10.1007/s00330-012-2515-1 · Cited by 12
Spectrum of PET–CT pelvic pitfalls in patients with gynecologic malignancies
Gorospe, L., Jover-Díaz, R., & Vicente-Bártulos, A. (2012) · Abdominal Imaging · doi:10.1007/s00261-012-9867-5 · Cited by 12
Ay, M. R., & Sarkar, S. (2007) · Iranian Journal of Nuclear Medicine · Cited by 12
Cho, J.-H., Lee, J.-H., Park, C., Lee, S.-Y., Lee, J., Moon, D.-H., & Lee, H.-K. (2014) · Journal of Magnetics · doi:10.4283/jmag.2014.19.3.248 · Cited by 11
Verburg, F. A., Kuhl, C. K., Pietsch, H., Palmowski, M., Mottaghy, F. M., & Behrendt, F. F. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.06.020 · Cited by 11
PET/CT Imaging in Head and Neck Tumors
Rödel, R. (2008) · Recent results in cancer research/Recent Results in Cancer Research · doi:10.1007/978-3-540-31203-1_4 · Cited by 11
Rebière, M., Verburg, F. A., Palmowski, M., Krohn, T., Pietsch, H., Kuhl, C. K., Mottaghy, F. M., & Behrendt, F. F. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2012.04.007 · Cited by 10
Bacharach, S. L. (2004) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2004.04.008 · Cited by 10
Overcorrection of iodinated contrast attenuation in SPECT‐CT: Phantom studies
Bonta, D., & Wahl, R. L. (2010) · Medical Physics · doi:10.1118/1.3483100 · Cited by 9
Self-citationPET-CT and diagnostic CT: The synergy of metabolic and morphological data in onco-haematology
Ricard, F., Giammarile, F., Tychyj-Pinel, C., Houzard, C., Decullier, É., Chateau, F., Manichon, A., Orliaguet, I., Michallet, A., Salles, G., et al. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.07.008 · Cited by 9
Verburg, F. A., Apitzsch, J., Lensing, C., Kuhl, C. K., Pietsch, H., Mottaghy, F. M., & Behrendt, F. F. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.09.013 · Cited by 8
Sarasúa, L. G., Aizpurúa, J. E., & Raman, S. (2006) · Radiología · doi:10.1016/s0033-8338(06)73156-3 · Cited by 8
Rodríguez‐Vigil, B., León, N. G., Pinilla, I., Hernández‐Maraver, D., Coya, J., & Curto, L. M. M. (2006) · Current Problems in Diagnostic Radiology · doi:10.1067/j.cpradiol.2006.02.001 · Cited by 8
Influence of PET/CT-introduction on PET scanning frequency and indications
Bockisch, A., Eschmann, S. M., Krause, B. J., Rödel, R., Tiling, R., Weckesser, M., & Stergar, H. (2007) · Nuklearmedizin - NuclearMedicine · doi:10.1055/s-0037-1621024 · Cited by 8
Sheppard, A. J., Theng, E., Paravastu, S. S., Wojnowski, N. M., Farhadi, F., Morris, M. A., Hartley, I. R., Gafni, R. I., Roszko, K. L., Collins, M. T., et al. (2024) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.123.320455 · Cited by 7
Optimisation of whole-body PET/CT scanning protocols
Zaidi, H. (2007) · Biomedical Imaging and Intervention Journal · doi:10.2349/biij.3.2.e36 · Cited by 7
Bidgoli, J. H., Ay, M. R., Sarkar, S., Ahmadian, A., & Zaidi, H. (2007) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2007.4436892 · Cited by 7
Bacharach, S. L. (2010) · doi:10.1002/9781444323894.ch1 · Cited by 6
McKeown, C., Dempsey, M.-F., Gillen, G., & Paterson, C. (2012) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e3283531d45 · Cited by 5
Identification of Contrast Media in PET/CT Using Dual Energy CT
Freedman, N. M. T., Maass‐Moreno, R., Meunier, L. L., & Bacharach, S. L. (2007) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2007.896210 · Cited by 5
INVITED REVIEW‐OFF‐SITE PET IMAGING PROGRAMS: CHALLENGES AND OPPORTUNITIES
LeBlanc, A. K., & Morandi, F. (2013) · Veterinary Radiology & Ultrasound · doi:10.1111/vru.12103 · Cited by 4
Pearls and Pitfalls in Interpretation of Abdominal and Pelvic
Blake, M. A., Singh, A. N., Slattery, J. M. A., Kalra, M. K., Maher, M. M., Sahani, D. V., Fischman, A. J., & Müeller, P. R. (2006) · Cited by 4
Practical issues in abdominal PET/CT
Blake, M. A., Slattery, J. M. A., Sahani, D. V., & Kalra, M. K. (2005) · Applied Radiology · doi:10.37549/ar1380 · Cited by 4
Feasibility of Diagnostic Contrast-enhanced CT for Attenuation Correction of WholeBody PET Images
Matsumoto, K., Nakamoto, Y., Sakamoto, S., Murase, K., & Senda, M. (2007) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.63.757 · Cited by 4
Self-citationPositron Emission Tomography and Computed Tomography of the Hollow Viscera
Butros, S. R., McDermott, S., Shelly, M. J., & Blake, M. A. (2015) · Elsevier eBooks · doi:10.1016/b978-1-4557-5117-4.00007-6 · Cited by 3
Is dedicated chest CT needed in addition to PET/CT for evaluation of pediatric oncology patients?
Goodman, S. Z., Rosenblum, J., Tuna, İ. S., Levsky, J. M., Ricafort, R. J., & Taragin, B. H. (2015) · Clinical Imaging · doi:10.1016/j.clinimag.2015.05.005 · Cited by 3
Application of CT Contrast Agents in PET-CT Imaging
Antoch, G., Veit, P., Bockisch, A., & Kuehl, H. (2010) · Springer eBooks · doi:10.1007/978-0-387-48902-5_9 · Cited by 3
Grecchi, E., O'Doherty, J., & Turkheimer, F. (2014) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2014.7430977 · Cited by 3
Bacharach, S. L. (2006) · doi:10.1002/9780470988534.ch1 · Cited by 3
Ay, M. R., & Zaidi, H. (2006) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2006.356444 · Cited by 2
The Comparative analysis of PET/CT and Contrast CT in the Evaluation of Patients with Lymphoma
Khalifa, N. M. (2010) · The Egyptian Journal Nuclear Medicine · doi:10.21608/egyjnm.2010.5496 · Cited by 2
Uso del sistema híbrido PET/TC en oncología: perspectiva radiológica
León, N. G., Pinilla, I., Rodríguez‐Vigil, B., Hernández, D., Reza, M., & Madero, R. (2007) · Radiología · doi:10.1016/s0033-8338(07)73713-x · Cited by 2
Photon attenuation correction in whole-body PET/MRI using tissue classification
Martínez-Möller, A., Souvatzoglou, M., & Nekolla, S. G. (2010) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2010.5490173 · Cited by 1
Jadvar, H., Fahey, F. H., & Shulkin, B. L. (2012) · Medical radiology · doi:10.1007/174_2012_576 · Cited by 1
Behrendt, F. F., Lensing, C., Keil, S., Mottaghy, F. M., & Verburg, F. A. (2016) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.12481 · Cited by 1
Early Radiographic Detection of Head and Neck Cancer: Positron Emission Tomography
Jacene, H. A. (2010) · Elsevier eBooks · doi:10.1016/b978-1-4160-5202-9.50010-7 · Cited by 1
Investigation of accuracy in quantitation of 18F-FDG concentration of PET/CT
Ishihara, Y. (2004) · doi:10.31390/gradschool_theses.176 · Cited by 1
How to Image a Child by PET–Computed Tomography
Kaste, S. C., & McCarville, M. B. (2006) · Springer eBooks · doi:10.1007/0-387-34641-4_9 · Cited by 1
Antoch, G. (2008) · Medical radiology · doi:10.1007/978-3-540-33125-4_33
Metadata
- Authors
- Nakamoto, Y., Chin, B. B., Kraitchman, D. L., Lawler, L. P., Marshall, L. T., & Wahl, R. L.
- Affiliations
- Johns Hopkins Medicine (US)
- Johns Hopkins University (US)
- Venue
- Radiology
- Published
- 2003-06
- Volume
- 227
- Issue
- 3
- Pages
- 817-824
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1995453959
- Cited by
- 111
- References
- 17
- Citations by year
- 2024: 1 · 2022: 1 · 2020: 1 · 2019: 2 · 2018: 4 · 2017: 3 · 2016: 1 · 2015: 3 · 2014: 3 · 2013: 6 · 2012: 7
- FWCI
- 10.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Radiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Advanced X-ray and CT Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Keywords
- PET/CT, fluorodeoxyglucose, attenuation correction, attenuation map, Hounsfield units, phantom study, canine model, PET quantification
- MeSH terms
- Animals, Contrast Media, Dogs, Humans, Image Processing, Computer-Assisted, Injections, Intravenous, Tomography, Emission-Computed, Tomography, X-Ray Computed, Phantoms, Imaging, Radiopharmaceuticals, Fluorodeoxyglucose F18
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review