Targeting of Hematopoietic Progenitor Cells with MR Contrast Agents
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
PURPOSE: To label human hematopoietic progenitor cells with various magnetic resonance (MR) imaging contrast agents and to obtain 1.5-T MR images of them. MATERIALS AND METHODS: Hematopoietic progenitor cells, labeled with ferumoxides, ferumoxtran, magnetic polysaccharide nanoparticles-transferrin, P7228 liposomes, and gadopentetate dimeglumine liposomes underwent MR imaging with T1- and T2-weighted spin-echo and fast field-echo sequences. Data were analyzed by measuring MR signal intensities and R1 and R2* relaxation rates of labeled cells and nonlabeled control cells. Mean quantitative data for the various contrast agent groups were assessed for significant differences compared with control cells by means of the Scheffe test. As a standard of reference, MR imaging data were compared with electron microscopic and spectrometric data. RESULTS: For all contrast agents, intracellular cytoplasm uptake was demonstrated with electron microscopy and was quantified with spectrometry. When compared with nonlabeled control cells, progenitor cells labeled with iron oxides showed significantly (P <.05) increased R2*. Cells labeled with gadopentetate dimeglumine liposomes showed significantly increased R1. Detection thresholds were 5 x 10(5) cells for gadopentetate dimeglumine liposomes and ferumoxtran, 2.5 x 10(5) cells for ferumoxides and P7228 liposomes, and 1 x 10(5) cells for magnetic polysaccharide nanoparticles-transferrin. CONCLUSION: Hematopoietic progenitor cells can be labeled with MR contrast agents and can be depicted with a standard 1.5-T MR imager.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bone marrow cells regenerate infarcted myocardium
Orlic, D., Kajstura, J., Chimenti, S., Jakoniuk, I., Anderson, S. M., Li, B., Pickel, J., McKay, R., Nadal-Ginard, B., Bodine, D. M., et al. (2001) · Nature · doi:10.1038/35070587 · Cited by 5,155
Lipofection: a highly efficient, lipid-mediated DNA-transfection procedure.
Felgner, P. L., Gadek, T. R., Holm, M., Roman, R., Chan, H. W., Wenz, M., Northrop, J. P., Ringold, G. M., & Danielsen, M. (1987) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.84.21.7413 · Cited by 4,978
Lewin, M., Carlesso, N., Tung, C.-H., Tang, X.-W., Cory, D., Scadden, D. T., & Weissleder, R. (2000) · Nature Biotechnology · doi:10.1038/74464 · Cited by 1,716
Characteristics of gadolinium-DTPA complex: a potential NMR contrast agent
Weinmann, H., Brasch, R., Press, W., & Wesbey, G. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.142.3.619 · Cited by 1,231
Superparamagnetic iron oxide: pharmacokinetics and toxicity
Weissleder, R., Stark, D., Engelstad, B., Bacon, B., Compton, C., White, D., Jacobs, P., & Lewis, J. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.1.167 · Cited by 1,045
Weissleder, R., Elizondo, G., Wittenberg, J., Rabito, C. A., Bengele, H. H., & Josephson, L. (1990) · Radiology · doi:10.1148/radiology.175.2.2326474 · Cited by 1,028
Magnetodendrimers allow endosomal magnetic labeling and in vivo tracking of stem cells
Bulte, J. W. M., Douglas, T., Witwer, B., Zhang, S.-C., Strable, E., Lewis, B. K., Zywicke, H., Miller, B., van Gelderen, P., Moskowitz, B. M., et al. (2001) · Nature Biotechnology · doi:10.1038/nbt1201-1141 · Cited by 1,027
Cationic liposome-mediated transfection
Felgner, P. L., & Ringold, G. M. (1989) · Nature · doi:10.1038/337387a0 · Cited by 987
High-Efficiency Intracellular Magnetic Labeling with Novel Superparamagnetic-Tat Peptide Conjugates
Josephson, L., Tung, C.-H., Moore, A., & Weissleder, R. (1999) · Bioconjugate Chemistry · doi:10.1021/bc980125h · Cited by 882
Pharmacokinetics of GdDTPA/dimeglumine after intravenous injection into healthy volunteers.
Weinmann, H., Laniado, M., & Mutzel, W. (1984) · PubMed · Cited by 610
Cited by
Iron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
Recent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
Superparamagnetic Iron Oxide Nanoparticle Probes for Molecular Imaging
Thorek, D. L. J., Chen, A. K., Czupryna, J., & Tsourkas, A. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9002-7 · Cited by 772
Efficient magnetic cell labeling with protamine sulfate complexed to ferumoxides for cellular MRI
Arbab, A. S., Yocum, G. T., Kalish, H., Jordan, E. K., Anderson, S. A., Khakoo, A. Y., Read, E. J., & Frank, J. A. (2004) · Blood · doi:10.1182/blood-2004-02-0655 · Cited by 529
Weinstein, J. S., Varallyay, C. G., Dosa, E., Gahramanov, S., Hamilton, B., Rooney, W. D., Muldoon, L. L., & Neuwelt, E. A. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2009.192 · Cited by 500
“Phagocytic cellular uptake of iron oxides increases with particle size (Daldrup-Link et al, 2003; Matuszewski et al, 2005).”
BackgroundDias, A. M. G. C., Hussain, A., Marcos, A. S., & Roque, A. C. A. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2010.10.003 · Cited by 376
Universal cell labelling with anionic magnetic nanoparticles
Wilhelm, C., & Gazeau, F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.016 · Cited by 343
Arbab, A. S., Yocum, G. T., Rad, A. M., Khakoo, A. Y., Fellowes, V., Read, E. J., & Frank, J. A. (2005) · NMR in Biomedicine · doi:10.1002/nbm.991 · Cited by 297
“on iron-sensitive T2-weighted and T2*-weighted gradient echo images [2,3,5–14].”
BackgroundModo, M., Hoehn, M., & Bulte, J. W. M. (2005) · Molecular Imaging · doi:10.1162/15353500200505145 · Cited by 294
In Vivo Tracking of Stem Cells for Clinical Trials in Cardiovascular Disease
Frangioni, J. V., & Hajjar, R. J. (2004) · Circulation · doi:10.1161/01.cir.0000149840.46523.fc · Cited by 269
Advanced in developmental organic and inorganic nanomaterial: a review
Khalid, K., Tan, X., Mohd Zaid, H. F., Tao, Y., Lye Chew, C., Chu, D.-T., Lam, M. K., Ho, Y.-C., Lim, J. W., & Chin Wei, L. (2020) · Bioengineered · doi:10.1080/21655979.2020.1736240 · Cited by 263
Capacity of human monocytes to phagocytose approved iron oxide MR contrast agents in vitro
Metz, S., Bonaterra, G., Rudelius, M., Settles, M., Rummeny, E., & Daldrup-Link, H. (2004) · European Radiology · doi:10.1007/s00330-004-2405-2 · Cited by 246
“Further, we did not monitor how long the labeling of the cells persists but the active phagocytic uptake of the particulate contrast agents should lead to persistent internalization for at least several days [ 22 ].”
BackgroundResultInfluentialSelf-citationBos, C., Delmas, Y., Desmoulière, A., Solanilla, A., Hauger, O., Grosset, C., Dubus, I., Ivanovic, Z., Rosenbaum, J., Charbord, P., et al. (2004) · Radiology · doi:10.1148/radiol.2333031714 · Cited by 232
Hsiao, J., Tsai, C., Chung, T., Hung, Y., Yao, M., Liu, H., Mou, C., Yang, C., Chen, Y., & Huang, D. (2008) · Small · doi:10.1002/smll.200701316 · Cited by 208
Kateb, B., Chiu, K., Black, K. L., Yamamoto, V., Khalsa, B., Ljubimova, J. Y., Ding, H., Patil, R., Portilla-Arias, J. A., Modo, M., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.01.105 · Cited by 188
Detection and quantification of magnetically labeled cells by cellular MRI
Liu, W., & Frank, J. A. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.09.021 · Cited by 182
Daldrup-Link, H. E., Rudelius, M., Piontek, G., Metz, S., Bräuer, R., Debus, G., Corot, C., Schlegel, J., Link, T. M., Peschel, C., et al. (2005) · Radiology · doi:10.1148/radiol.2341031236 · Cited by 170
“P7228 particles are negatively charged and thus can be entrapped with cationic liposomes ( 15 ,19).”
BackgroundMethodSelf-citationClinical applications of iron oxide nanoparticles for magnetic resonance imaging of brain tumors
Iv, M., Telischak, N., Feng, D., Holdsworth, S. J., Yeom, K. W., & Daldrup-Link, H. E. (2015) · Nanomedicine · doi:10.2217/nnm.14.203 · Cited by 134
Self-citationRefining in vitro models for nanomaterial exposure to cells and tissues
Guggenheim, E. J., Milani, S., Röttgermann, P. J. F., Dusinska, M., Saout, C., Salvati, A., Rädler, J. O., & Lynch, I. (2018) · NanoImpact · doi:10.1016/j.impact.2018.02.008 · Cited by 36
Metadata
- Authors
- Daldrup-Link, H. E., Rudelius, M., Oostendorp, R. A. J., Settles, M., Piontek, G., Metz, S., Rosenbrock, H., Keller, U., Heinzmann, U., Rummeny, E. J., Schlegel, J., & Link, T. M.
- Venue
- Radiology
- Published
- 2003-09
- Volume
- 228
- Issue
- 3
- Pages
- 760-767
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2000331662
- Cited by
- 200
- References
- 25
- FWCI
- 12.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.