The DOI matches its Crossref record.
Evaluation of Neck and Body Metastases to Nodes with Ferumoxtran 10–enhanced MR Imaging: Phase III Safety and Efficacy Study
Abstract
PURPOSE: To determine the safety and efficacy of ferumoxtran 10-enhanced magnetic resonance (MR) imaging for diagnosis of metastases to lymph nodes and the clinical usefulness of ferumoxtran 10 in nodal staging. MATERIALS AND METHODS: One hundred fifty-two patients were injected with ferumoxtran 10. Readers independently evaluated precontrast MR images by using node size criteria and subjective assessment of other imaging features. Ferumoxtran 10-enhanced MR images were evaluated alone and paired with precontrast images for comparison. The diagnostic performances of precontrast MR size criteria and postcontrast MR imaging were evaluated with receiver operating characteristic (ROC) analysis. Lymph node signal intensity was correlated with histopathologic findings. MR imaging and histopathologic nodal stages were compared. RESULTS: Node-level sensitivity, specificity, and accuracy of precontrast MR imaging were 54%, 82%, and 68%, respectively, with node size criterion alone; 91%, 51%, and 71%, respectively, with subjective reader assessment; 85%, 85%, and 85%, respectively, with postcontrast MR imaging alone; and 83%, 77%, and 80%, respectively, with paired pre- and postcontrast MR imaging. Compared with size criteria, subjective reader assessment had higher sensitivity but substantially lower specificity. Areas under the ROC curve for pre- and postcontrast MR imaging were 0.76 and 0.83, respectively. Nonmetastatic nodes had significantly lower signal intensity than metastatic nodes on postcontrast T2-weighted MR images (P <.001). Postcontrast nodal staging was significantly more accurate than precontrast nodal staging (P <.01). Headache, back pain, vasodilatation, and urticaria each occurred in 6% of patients. CONCLUSION: Ferumoxtran 10-enhanced MR imaging was safe and effective and facilitated improved diagnostic performance. Use of iron oxide-enhanced MR imaging increased the positive predictive value by 20% and the accuracy by 14% compared with reader assessment. Differentiating patients with no nodal metastatic involvement was more reliable with ferumoxtran 10-enhanced MR imaging than with precontrast MR imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Zanganeh, S., Hutter, G., Spitler, R., Lenkov, O., Mahmoudi, M., Shaw, A., Pajarinen, J. S., Nejadnik, H., Goodman, S., Moseley, M., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.168 · Cited by 1,647
Biological applications of magnetic nanoparticles
Colombo, M., Carregal-Romero, S., Casula, M. F., Gutiérrez, L., Morales, M. P., Böhm, I. B., Heverhagen, J. T., Prosperi, D., & Parak, W. J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15337h · Cited by 1,315
Potential toxicity of superparamagnetic iron oxide nanoparticles (SPION)
Singh, N., Jenkins, G. J. S., Asadi, R., & Doak, S. H. (2010) · Nano Reviews · doi:10.3402/nano.v1i0.5358 · Cited by 1,112
Superparamagnetic Iron Oxide Nanoparticles—Current and Prospective Medical Applications
Dulińska-Litewka, J., Łazarczyk, A., Hałubiec, P., Szafrański, O., Karnas, K., & Karewicz, A. (2019) · Materials · doi:10.3390/ma12040617 · Cited by 580
Metadata
- Authors
- Anzai, Y., Piccoli, C. W., Outwater, E. K., Stanford, W., Bluemke, D. A., Nurenberg, P., Saini, S., Maravilla, K. R., Feldman, D. E., Schmiedl, U. P., Brunberg, J. A., Francis, I. R., Harms, S. E., Som, P. M., & Tempany, C. M.
- Venue
- Radiology
- Published
- 2003-09
- Volume
- 228
- Issue
- 3
- Pages
- 777-788
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2036851552
- Cited by
- 289
- References
- 0
- FWCI
- 12.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Neck and Body Metastases to Nodes with Ferumoxtran 10–enhanced MR Imaging: Phase III Safety and Efficacy Study. https://app.cochat.ai/papers/10.1148/radiol.2283020872
- The paper
- Anzai, Y., Piccoli, C. W., Outwater, E. K., Stanford, W., Bluemke, D. A., Nurenberg, P., Saini, S., Maravilla, K. R., Feldman, D. E., Schmiedl, U. P., Brunberg, J. A., Francis, I. R., Harms, S. E., Som, P. M., & Tempany, C. M. (2003). Evaluation of Neck and Body Metastases to Nodes with Ferumoxtran 10–enhanced MR Imaging: Phase III Safety and Efficacy Study. Radiology. https://doi.org/10.1148/radiol.2283020872
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.