Evaluation of Neck and Body Metastases to Nodes with Ferumoxtran 10–enhanced MR Imaging: Phase III Safety and Efficacy Study
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
PURPOSE: To determine the safety and efficacy of ferumoxtran 10-enhanced magnetic resonance (MR) imaging for diagnosis of metastases to lymph nodes and the clinical usefulness of ferumoxtran 10 in nodal staging. MATERIALS AND METHODS: One hundred fifty-two patients were injected with ferumoxtran 10. Readers independently evaluated precontrast MR images by using node size criteria and subjective assessment of other imaging features. Ferumoxtran 10-enhanced MR images were evaluated alone and paired with precontrast images for comparison. The diagnostic performances of precontrast MR size criteria and postcontrast MR imaging were evaluated with receiver operating characteristic (ROC) analysis. Lymph node signal intensity was correlated with histopathologic findings. MR imaging and histopathologic nodal stages were compared. RESULTS: Node-level sensitivity, specificity, and accuracy of precontrast MR imaging were 54%, 82%, and 68%, respectively, with node size criterion alone; 91%, 51%, and 71%, respectively, with subjective reader assessment; 85%, 85%, and 85%, respectively, with postcontrast MR imaging alone; and 83%, 77%, and 80%, respectively, with paired pre- and postcontrast MR imaging. Compared with size criteria, subjective reader assessment had higher sensitivity but substantially lower specificity. Areas under the ROC curve for pre- and postcontrast MR imaging were 0.76 and 0.83, respectively. Nonmetastatic nodes had significantly lower signal intensity than metastatic nodes on postcontrast T2-weighted MR images (P <.001). Postcontrast nodal staging was significantly more accurate than precontrast nodal staging (P <.01). Headache, back pain, vasodilatation, and urticaria each occurred in 6% of patients. CONCLUSION: Ferumoxtran 10-enhanced MR imaging was safe and effective and facilitated improved diagnostic performance. Use of iron oxide-enhanced MR imaging increased the positive predictive value by 20% and the accuracy by 14% compared with reader assessment. Differentiating patients with no nodal metastatic involvement was more reliable with ferumoxtran 10-enhanced MR imaging than with precontrast MR imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weissleder, R., Elizondo, G., Wittenberg, J., Lee, A. S., Josephson, L., & Brady, T. J. (1990) · Radiology · doi:10.1148/radiology.175.2.2326475 · Cited by 492
Comparison of CT and MR imaging in staging of neck metastases.
Curtin, H. D., Ishwaran, H., Mancuso, A. A., Dalley, R. W., Caudry, D. J., & McNeil, B. J. (1998) · Radiology · doi:10.1148/radiology.207.1.9530307 · Cited by 394
Tumoral Distribution of Long-circulating Dextran-coated Iron Oxide Nanoparticles in a Rodent Model
Moore, A., Marecos, E., Bogdanov, A., & Weissleder, R. (2000) · Radiology · doi:10.1148/radiology.214.2.r00fe19568 · Cited by 343
Ros, P. R., Freeny, P. C., Harms, S. E., Seltzer, S. E., Davis, P. L., Chan, T. W., Stillman, A. E., Muroff, L. R., Runge, V. M., & Nissenbaum, M. A. (1995) · Radiology · doi:10.1148/radiology.196.2.7617864 · Cited by 278
Self-citationBellin, M. F., Roy, C., Kinkel, K., Thoumas, D., Zaim, S., Vanel, D., Tuchmann, C., Richard, F., Jacqmin, D., Delcourt, A., et al. (1998) · Radiology · doi:10.1148/radiology.207.3.9609907 · Cited by 261
Anzai, Y., Blackwell, K. E., Hirschowitz, S. L., Rogers, J. W., Sato, Y., Yuh, W. T., Runge, V. M., Morris, M. R., McLachlan, S. J., & Lufkin, R. B. (1994) · Radiology · doi:10.1148/radiology.192.3.7520182 · Cited by 220
Self-citationPhase I clinical evaluation of a new iron oxide MR contrast agent
McLachlan, S. J., Morris, M. R., Lucas, M. A., Fisco, R. A., Eakins, M. N., Fowler, D. R., Scheetz, R. B., & Olukotun, A. Y. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040313 · Cited by 194
Harisinghani, M. G., Saini, S., Weissleder, R., Hahn, P. F., Yantiss, R. K., Tempany, C., Wood, B. J., & Mueller, P. R. (1999) · American Journal of Roentgenology · doi:10.2214/ajr.172.5.10227514 · Cited by 174
Self-citationSigal, R., Vogl, T., Casselman, J., Moulin, G., Veillon, F., Hermans, R., Dubrulle, F., Viala, J., Bosq, J., Mack, M., et al. (2002) · European Radiology · doi:10.1007/s003300101130 · Cited by 160
Várallyay, P., Nesbit, G. M., Muldoon, L. L., Nixon, R. R., Delashaw, J. B., Cohen, J. I., Petrillo, A., Rink, D., & Neuwelt, E. A. (2002) · PubMed Central · Cited by 149
Cited by
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Zanganeh, S., Hutter, G., Spitler, R., Lenkov, O., Mahmoudi, M., Shaw, A., Pajarinen, J. S., Nejadnik, H., Goodman, S., Moseley, M., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.168 · Cited by 1,647
Synthesis, Functionalization, and Biomedical Applications of Multifunctional Magnetic Nanoparticles
Hao, R., Xing, R., Xu, Z., Hou, Y., Gao, S., & Sun, S. (2010) · Advanced Materials · doi:10.1002/adma.201000260 · Cited by 1,372
Biological applications of magnetic nanoparticles
Colombo, M., Carregal-Romero, S., Casula, M. F., Gutiérrez, L., Morales, M. P., Böhm, I. B., Heverhagen, J. T., Prosperi, D., & Parak, W. J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15337h · Cited by 1,315
Potential toxicity of superparamagnetic iron oxide nanoparticles (SPION)
Singh, N., Jenkins, G. J. S., Asadi, R., & Doak, S. H. (2010) · Nano Reviews · doi:10.3402/nano.v1i0.5358 · Cited by 1,112
“Iron released from SPION is metabolised in the liver and subsequently used in the formation of red blood cells or excreted via kidneys (43).”
BackgroundSuperparamagnetic Iron Oxide Nanoparticle Probes for Molecular Imaging
Thorek, D. L. J., Chen, A. K., Czupryna, J., & Tsourkas, A. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9002-7 · Cited by 772
Superparamagnetic Iron Oxide Nanoparticles—Current and Prospective Medical Applications
Dulińska-Litewka, J., Łazarczyk, A., Hałubiec, P., Szafrański, O., Karnas, K., & Karewicz, A. (2019) · Materials · doi:10.3390/ma12040617 · Cited by 580
Applications and potential toxicity of magnetic iron oxide nanoparticles
Liu, G., Gao, J., Ai, H., & Chen, X. (2013) · Small · doi:10.1002/smll.201201531 · Cited by 570
Nanoplatforms for Targeted Molecular Imaging in Living Subjects
Cai, W., & Chen, X. (2007) · Small · doi:10.1002/smll.200700351 · Cited by 563
Laurent, S., Saei, A. A., Behzadi, S., Panahifar, A., & Mahmoudi, M. (2014) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2014.924501 · Cited by 445
Horwich, A., Shipley, J., & Huddart, R. (2006) · The Lancet · doi:10.1016/s0140-6736(06)68305-0 · Cited by 398
Emerging applications for ferumoxytol as a contrast agent in MRI
Bashir, M. R., Bhatti, L., Marin, D., & Nelson, R. C. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24691 · Cited by 371
Rockall, A. G., Sohaib, S. A., Harisinghani, M. G., Babar, S. A., Singh, N., Jeyarajah, A. R., Oram, D. H., Jacobs, I. J., Shepherd, J. H., & Reznek, R. H. (2005) · Journal of Clinical Oncology · doi:10.1200/jco.2005.07.166 · Cited by 342
Bourrinet, P., Bengele, H. H., Bonnemain, B., Dencausse, A., Idee, J.-M., Jacobs, P. M., & Lewis, J. M. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000197669.80475.dd · Cited by 339
Current and potential imaging applications of ferumoxytol for magnetic resonance imaging
Toth, G. B., Varallyay, C. G., Horvath, A., Bashir, M. R., Choyke, P. L., Daldrup-Link, H. E., Dosa, E., Finn, J. P., Gahramanov, S., Harisinghani, M., et al. (2017) · Kidney International · doi:10.1016/j.kint.2016.12.037 · Cited by 317
“Optimal node T2*-weighted imaging contrast with ferumoxytol can be achieved 24 to 48 hours following injection (Figures 12 and 13).(16,79)”
Wang, A. Z., Bagalkot, V., Vasilliou, C. C., Gu, F., Alexis, F., Zhang, L., Shaikh, M., Yuet, K., Cima, M. J., Langer, R., et al. (2008) · ChemMedChem · doi:10.1002/cmdc.200800091 · Cited by 312
Diagnostic precision of nanoparticle-enhanced MRI for lymph-node metastases: a meta-analysis
Will, O., Purkayastha, S., Chan, C., Athanasiou, T., Darzi, A. W., Gedroyc, W., & Tekkis, P. P. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(05)70537-4 · Cited by 260
(2004) · PubMed · Cited by 211
Magnetic nanoparticles: an update of application for drug delivery and possible toxic effects
Kim, J.-E., Shin, J.-Y., & Cho, M.-H. (2012) · Archives of Toxicology · doi:10.1007/s00204-011-0773-3 · Cited by 192
“Iron released from MNPs is metabolized in the RES and subsequently used to form red blood cells or excreted via the kidneys (Anzai et al. 2003).”
BackgroundMuldoon, L. L., Manninger, S., Pinkston, K. E., & Neuwelt, E. A. (2005) · Neurosurgery · doi:10.1093/neurosurgery/57.4.785 · Cited by 190
Magnetic Nanoparticles for Cancer Diagnosis and Therapy
Yigit, M. V., Moore, A., & Medarova, Z. (2012) · Pharmaceutical Research · doi:10.1007/s11095-012-0679-7 · Cited by 188
Positron emission imaging of head and neck cancer, including thyroid carcinoma
Schöder, H., & Yeung, H. W. D. (2004) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2004.03.004 · Cited by 176
Morishige, K., Kacher, D. F., Libby, P., Josephson, L., Ganz, P., Weissleder, R., & Aikawa, M. (2010) · Circulation · doi:10.1161/circulationaha.109.891804 · Cited by 168
Clinical applications of iron oxide nanoparticles for magnetic resonance imaging of brain tumors
Iv, M., Telischak, N., Feng, D., Holdsworth, S. J., Yeom, K. W., & Daldrup-Link, H. E. (2015) · Nanomedicine · doi:10.2217/nnm.14.203 · Cited by 134
Das, B., Mandal, M., Upadhyay, A., Chattopadhyay, P., & Karak, N. (2013) · Biomedical Materials · doi:10.1088/1748-6041/8/3/035003 · Cited by 122
Bernd, H., De Kerviler, E., Gaillard, S., & Bonnemain, B. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e3181a0068b · Cited by 115
Application of nanoparticles on diagnosis and therapy in gliomas.
Hernández-Pedro, N. Y., Rangel-López, E., Magaña-Maldonado, R., de la Cruz, V. P., Santamaría del Angel, A., Pineda, B., & Sotelo, J. (2013) · BioMed Research International · doi:10.1155/2013/351031 · Cited by 84
Tracking stem cells with superparamagnetic iron oxide nanoparticles: perspectives and considerations
Jasmin, Souza, G. T., Andrade Louzada, R., Rosado-de-Castro, P. H., Mendez-Otero, R., & Carvalho, A. C. C. (2017) · International Journal of Nanomedicine · doi:10.2147/ijn.s126530 · Cited by 78
“The toxicologic aspects of the nanoparticles deserve attention in experimental and clinical applications, but the toxicity results described in this section may have little impact on the general health of a patient after cell transplantation.(82,83,99) However, the effects on the properties of cells to be utilized in…”
BackgroundRecent Advances in the Development of Magnetic Nanoparticles for Biomedical Applications
Monteserín, M., Larumbe, S., Martínez, A. V., Burgui, S., & Francisco Martín, L. (2021) · Journal of Nanoscience and Nanotechnology · doi:10.1166/jnn.2021.19062 · Cited by 27
Metadata
- Authors
- Anzai, Y., Piccoli, C. W., Outwater, E. K., Stanford, W., Bluemke, D. A., Nurenberg, P., Saini, S., Maravilla, K. R., Feldman, D. E., Schmiedl, U. P., Brunberg, J. A., Francis, I. R., Harms, S. E., Som, P. M., & Tempany, C. M.
- Venue
- Radiology
- Published
- 2003-09
- Volume
- 228
- Issue
- 3
- Pages
- 777-788
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2036851552
- Cited by
- 289
- References
- 21
- FWCI
- 12.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.