Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 163

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Patient Radiation Dose at CT Urography and Conventional Urography

Nawfel, Richard D., Judy, Philip F., Schleipman, A. Robert, Silverman, Stuart G. · 2004 · Radiology

Abstract

PURPOSE: To measure and compare patient radiation dose from computed tomographic (CT) urography and conventional urography and to compare these doses with dose estimates determined from phantom measurements. MATERIALS AND METHODS: Patient skin doses were determined by placing a thermoluminescent dosimeter (TLD) strip (six TLD chips) on the abdomen of eight patients examined with CT urography and 11 patients examined with conventional urography. CT urography group consisted of two women and six men (mean age, 55.5 years), and conventional urography group consisted of six women and five men (mean age, 58.9 years). CT urography protocol included three volumetric acquisitions of the abdomen and pelvis. Conventional urography protocol consisted of acquisition of several images involving full nephrotomography and oblique projections. Mean and SD of measured patient doses were compared with corresponding calculated doses and with dose measured on a Lucite pelvic-torso phantom. Correlation coefficient (R(2)) was calculated to compare measured and calculated skin doses for conventional urography examination, and two-tailed P value significance test was used to evaluate variation in effective dose with patient size. Radiation risk was calculated from effective dose estimates. RESULTS: Mean patient skin doses for CT urography measured with TLD strips and calculated from phantom data (CT dose index) were 56.3 mGy +/- 11.5 and 54.6 mGy +/- 4.1, respectively. Mean patient skin doses for conventional urography measured with TLD strips and calculated as entrance skin dose were 151 mGy +/- 90 and 145 mGy +/- 76, respectively. Correlation coefficient between measured and calculated skin doses for conventional urography examinations was 0.95. Mean effective dose estimates for CT urography and conventional urography were 14.8 mSv +/- 90.0 and 9.7 mSv +/- 3.0, respectively. Mean effective doses estimated for the pelvic-torso phantom were 15.9 mSv (CT urography) and 7.8 mSv (conventional urography). CONCLUSION: Standard protocol for CT urography led to higher mean effective dose, approximately 1.5 times the radiation risk for conventional urography. Patient dose estimates should be taken into consideration when imaging protocols are established for CT urography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2321030222

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 163

Metadata

Authors
Nawfel, R. D., Judy, P. F., Schleipman, A. R., & Silverman, S. G.
Venue
Radiology
Published
2004-07
Volume
232
Issue
1
Pages
126-132
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2146204128
Cited by
163
References
1
FWCI
9.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Patient Radiation Dose at CT Urography and Conventional Urography. https://app.cochat.ai/papers/10.1148/radiol.2321030222
The paper
Nawfel, R. D., Judy, P. F., Schleipman, A. R., & Silverman, S. G. (2004). Patient Radiation Dose at CT Urography and Conventional Urography. Radiology. https://doi.org/10.1148/radiol.2321030222

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.