Lung Image Database Consortium: Developing a Resource for the Medical Imaging Research Community
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
To stimulate the advancement of computer-aided diagnostic (CAD) research for lung nodules in thoracic computed tomography (CT), the National Cancer Institute launched a cooperative effort known as the Lung Image Database Consortium (LIDC). The LIDC is composed of five academic institutions from across the United States that are working together to develop an image database that will serve as an international research resource for the development, training, and evaluation of CAD methods in the detection of lung nodules on CT scans. Prior to the collection of CT images and associated patient data, the LIDC has been engaged in a consensus process to identify, address, and resolve a host of challenging technical and clinical issues to provide a solid foundation for a scientifically robust database. These issues include the establishment of (a) a governing mission statement, (b) criteria to determine whether a CT scan is eligible for inclusion in the database, (c) an appropriate definition of the term qualifying nodule, (d) an appropriate definition of "truth" requirements, (e) a process model through which the database will be populated, and (f) a statistical framework to guide the application of assessment methods by users of the database. Through a consensus process in which careful planning and proper consideration of fundamental issues have been emphasized, the LIDC database is expected to provide a powerful resource for the medical imaging research community. This article is intended to share with the community the breadth and depth of these key issues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early Lung Cancer Action Project: overall design and findings from baseline screening
Henschke, C. I., McCauley, D. I., Yankelevitz, D. F., Naidich, D. P., McGuinness, G., Miettinen, O. S., Libby, D. M., Pasmantier, M. W., Koizumi, J., Altorki, N. K., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(99)06093-6 · Cited by 2,508
Self-citationHistological Typing of Lung and Pleural Tumours
Travis, W. D., Colby, T. V., Corrin, B., Shimosato, Y., & Brambilla, E. (1999) · Springer eBooks · doi:10.1007/978-3-642-60049-4 · Cited by 1,523
Mass screening for lung cancer with mobile spiral computed tomography scanner
Sone, S., Takashima, S., Li, F., Yang, Z., Honda, T., Maruyama, Y., Hasegawa, M., Yamanda, T., Kubo, K., Hanamura, K., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(97)08229-9 · Cited by 931
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Austin, J. H., Müller, N. L., Friedman, P. J., Hansell, D. M., Naidich, D. P., Remy-Jardin, M., Webb, W. R., & Zerhouni, E. A. (1996) · Radiology · doi:10.1148/radiology.200.2.8685321 · Cited by 836
Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography.
Kaneko, M., Eguchi, K., Ohmatsu, H., Kakinuma, R., Naruke, T., Suemasu, K., & Moriyama, N. (1996) · Radiology · doi:10.1148/radiology.201.3.8939234 · Cited by 831
Computer-aided diagnosis in chest radiography: a survey
Van Ginneken, B., Ter Haar Romeny, B. M., & Viergever, M. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974918 · Cited by 516
Lee, Y., Hara, T., Fujita, H., Itoh, S., & Ishigaki, T. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932744 · Cited by 457
Tuddenham, W. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.143.3.509 · Cited by 336
Gurcan, M. N., Sahiner, B., Petrick, N., Chan, H., Kazerooni, E. A., Cascade, P. N., & Hadjiiski, L. (2002) · Medical Physics · doi:10.1118/1.1515762 · Cited by 309
Self-citation
Cited by
Armato, S. G., McLennan, G., Bidaut, L., McNitt‐Gray, M. F., Meyer, C. R., Reeves, A. P., Zhao, B., Aberle, D. R., Henschke, C. I., Hoffman, E. A., et al. (2011) · Medical Physics · doi:10.1118/1.3528204 · Cited by 2,887
Self-citationComparison and evaluation of methods for liver segmentation from CT datasets
Heimann, T., van Ginneken, B., Styner, M. A., Arzhaeva, Y., Aurich, V., Bauer, C., Beck, A., Becker, C., Beichel, R., Bekes, G., et al. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2013851 · Cited by 1,135
Diffusion models in medical imaging: A comprehensive survey
Kazerouni, A., Aghdam, E. K., Heidari, M., Azad, R., Fayyaz, M., Hacihaliloglu, I., & Merhof, D. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102846 · Cited by 765
Cheng, J.-Z., Ni, D., Chou, Y.-H., Qin, J., Tiu, C.-M., Chang, Y.-C., Huang, C.-S., Shen, D., & Chen, C.-M. (2016) · Scientific Reports · doi:10.1038/srep24454 · Cited by 755
Computer analysis of computed tomography scans of the lung: a survey
Sluimer, I., Schilham, A., Prokop, M., & van Ginneken, B. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.862753 · Cited by 556
Yu-Jen Chen, Y.-J., Hua, K.-L., Hsu, C.-H., Cheng, W.-H., & Hidayati, S. C. (2015) · OncoTargets and Therapy · doi:10.2147/ott.s80733 · Cited by 542
A new computationally efficient CAD system for pulmonary nodule detection in CT imagery
Messay, T., Hardie, R. C., & Rogers, S. K. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.02.004 · Cited by 439
Lung Nodule Classification Using Deep Features in CT Images
Kumar, D., Wong, A., & Clausi, D. A. (2015) · 2015 12th Conference on Computer and Robot Vision · doi:10.1109/crv.2015.25 · Cited by 398
“LIDC (Lung Cancer Data Consortium) [5], [6] is one such database which contains CT images of thoracic region for 1010 patients along with the annotation data of suspicious nodules (for both benign and malignant cases) for a size greater than 3 mm from upto four radiologists collected over a long…”
BackgroundSchaap, M., Metz, C. T., van Walsum, T., van der Giessen, A. G., Weustink, A. C., Mollet, N. R., Bauer, C., Bogunović, H., Castro, C., Deng, X., et al. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.06.003 · Cited by 362
Med3D: Transfer Learning for 3D Medical Image Analysis
Chen, S., Ma, K., & Zheng, Y. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1904.00625 · Cited by 317
Giger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311
Computer-aided Diagnosis: How to Move from the Laboratory to the Clinic
van Ginneken, B., Schaefer-Prokop, C. M., & Prokop, M. (2011) · Radiology · doi:10.1148/radiol.11091710 · Cited by 306
van Ginneken, B., Armato, S. G., de Hoop, B., van Amelsvoort-van de Vorst, S., Duindam, T., Niemeijer, M., Murphy, K., Schilham, A., Retico, A., Fantacci, M. E., et al. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.05.005 · Cited by 298
Kuhnigk, J.-M., Dicken, V., Bornemann, L., Bakai, A., Wormanns, D., Krass, S., & Peitgen, H.-O. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.871547 · Cited by 288
Computer-Aided Diagnosis Systems for Lung Cancer: Challenges and Methodologies
El-Baz, A., Beache, G. M., Gimel'farb, G., Suzuki, K., Okada, K., Elnakib, A., Soliman, A., & Abdollahi, B. (2013) · International Journal of Biomedical Imaging · doi:10.1155/2013/942353 · Cited by 277
Building a reference multimedia database for interstitial lung diseases
Depeursinge, A., Vargas, A., Platon, A., Geissbuhler, A., Poletti, P.-A., & Müller, H. (2012) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2011.07.003 · Cited by 248
Tan, M., Deklerck, R., Jansen, B., Bister, M., & Cornelis, J. (2011) · Medical Physics · doi:10.1118/1.3633941 · Cited by 221
“…region if (i) these voxels are adjacent to (in terms of the 26-neighbourhood in 3D image space) the seed region and (ii) their nodule filter values (extracted from the nodule-enhanced image) are within a range of [ (cid:2) 10, þ 10] centered around the most recent voxel included in the segmentation.”
BackgroundMcNitt-Gray, M. F., Armato, S. G., Meyer, C. R., Reeves, A. P., McLennan, G., Pais, R. C., Freymann, J., Brown, M. S., Engelmann, R. M., Bland, P. H., et al. (2007) · Academic Radiology · doi:10.1016/j.acra.2007.07.021 · Cited by 217
Self-citationAmbiguous Medical Image Segmentation Using Diffusion Models
Rahman, A., Valanarasu, J. M. J., Hacihaliloglu, I., & Patel, V. M. (2023) · 2023 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr52729.2023.01110 · Cited by 214
Carbontracker: Tracking and Predicting the Carbon Footprint of Training Deep Learning Models
Anthony, L. F. W., Kanding, B., & Selvan, R. (2020) · arXiv · doi:10.48550/arxiv.2007.03051 · Cited by 255
Pati, S., Baid, U., Edwards, B., Sheller, M. J., Foley, P., Anthony Reina, G., Thakur, S., Sako, C., Bilello, M., Davatzikos, C., et al. (2022) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ac9449 · Cited by 51
Metadata
- Authors
- Armato III, S. G., McLennan, G., McNitt-Gray, M. F., Meyer, C. R., Yankelevitz, D., Aberle, D. R., Henschke, C. I., Hoffman, E. A., Kazerooni, E. A., MacMahon, H., Reeves, A. P., Croft, B. Y., & Clarke, L. P.
- Venue
- Radiology
- Published
- 2004-09
- Volume
- 232
- Issue
- 3
- Pages
- 739-748
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2136325898
- Cited by
- 380
- References
- 24
- FWCI
- 17.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.