Lung Image Database Consortium: Developing a Resource for the Medical Imaging Research Community
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
To stimulate the advancement of computer-aided diagnostic (CAD) research for lung nodules in thoracic computed tomography (CT), the National Cancer Institute launched a cooperative effort known as the Lung Image Database Consortium (LIDC). The LIDC is composed of five academic institutions from across the United States that are working together to develop an image database that will serve as an international research resource for the development, training, and evaluation of CAD methods in the detection of lung nodules on CT scans. Prior to the collection of CT images and associated patient data, the LIDC has been engaged in a consensus process to identify, address, and resolve a host of challenging technical and clinical issues to provide a solid foundation for a scientifically robust database. These issues include the establishment of (a) a governing mission statement, (b) criteria to determine whether a CT scan is eligible for inclusion in the database, (c) an appropriate definition of the term qualifying nodule, (d) an appropriate definition of "truth" requirements, (e) a process model through which the database will be populated, and (f) a statistical framework to guide the application of assessment methods by users of the database. Through a consensus process in which careful planning and proper consideration of fundamental issues have been emphasized, the LIDC database is expected to provide a powerful resource for the medical imaging research community. This article is intended to share with the community the breadth and depth of these key issues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early Lung Cancer Action Project: overall design and findings from baseline screening
Henschke, C. I., McCauley, D. I., Yankelevitz, D. F., Naidich, D. P., McGuinness, G., Miettinen, O. S., Libby, D. M., Pasmantier, M. W., Koizumi, J., Altorki, N. K., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(99)06093-6 · Cited by 2,508
Self-citationHistological Typing of Lung and Pleural Tumours
Travis, W. D., Colby, T. V., Corrin, B., Shimosato, Y., & Brambilla, E. (1999) · Springer eBooks · doi:10.1007/978-3-642-60049-4 · Cited by 1,523
Mass screening for lung cancer with mobile spiral computed tomography scanner
Sone, S., Takashima, S., Li, F., Yang, Z., Honda, T., Maruyama, Y., Hasegawa, M., Yamanda, T., Kubo, K., Hanamura, K., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(97)08229-9 · Cited by 931
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Austin, J. H., Müller, N. L., Friedman, P. J., Hansell, D. M., Naidich, D. P., Remy-Jardin, M., Webb, W. R., & Zerhouni, E. A. (1996) · Radiology · doi:10.1148/radiology.200.2.8685321 · Cited by 836
Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography.
Kaneko, M., Eguchi, K., Ohmatsu, H., Kakinuma, R., Naruke, T., Suemasu, K., & Moriyama, N. (1996) · Radiology · doi:10.1148/radiology.201.3.8939234 · Cited by 831
Computer-aided diagnosis in chest radiography: a survey
Van Ginneken, B., Ter Haar Romeny, B. M., & Viergever, M. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974918 · Cited by 516
Lee, Y., Hara, T., Fujita, H., Itoh, S., & Ishigaki, T. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932744 · Cited by 457
Tuddenham, W. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.143.3.509 · Cited by 336
Gurcan, M. N., Sahiner, B., Petrick, N., Chan, H., Kazerooni, E. A., Cascade, P. N., & Hadjiiski, L. (2002) · Medical Physics · doi:10.1118/1.1515762 · Cited by 309
Self-citationAutomated detection of lung nodules in CT scans: Preliminary results
Armato, S. G., Giger, M. L., & MacMahon, H. (2001) · Medical Physics · doi:10.1118/1.1387272 · Cited by 250
Self-citationData explosion: the challenge of multidetector-row CT
Rubin, G. D. (2000) · European Journal of Radiology · doi:10.1016/s0720-048x(00)00270-9 · Cited by 208
Li, F., Sone, S., Abe, H., MacMahon, H., Armato, S. G., & Doi, K. (2002) · Radiology · doi:10.1148/radiol.2253011375 · Cited by 201
Self-citationComputerized Detection of Pulmonary Nodules in Computed Tomography Images
GIGER, M. L., BAE, K. T., & MacMAHON, H. (1994) · Investigative Radiology · doi:10.1097/00004424-199404000-00013 · Cited by 200
Self-citationMcNitt‐Gray, M. F., Hart, E. M., Wyckoff, N., Sayre, J. W., Goldin, J. G., & Aberle, D. R. (1999) · Medical Physics · doi:10.1118/1.598603 · Cited by 184
Self-citationPatient-specific models for lung nodule detection and surveillance in CT images
Brown, M. S., McNitt-Gray, M. F., Goldin, J. G., Suh, R. D., Sayre, J. W., & Aberle, D. R. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974919 · Cited by 169
Self-citationDetection Failures in Spiral CT Screening for Lung Cancer: Analysis of CT Findings
Kakinuma, R., Ohmatsu, H., Kaneko, M., Eguchi, K., Naruke, T., Nagai, K., Nishiwaki, Y., Suzuki, A., & Moriyama, N. (1999) · Radiology · doi:10.1148/radiology.212.1.r99jn1461 · Cited by 121
Primary carcinoma of the lung overlooked at CT: analysis of findings in 14 patients.
WHITE, C. S., Romney, B. M., Mason, A. C., Austin, J. H. M., Miller, B. H., & Protopapas, Z. (1996) · Radiology · doi:10.1148/radiology.199.1.8633131 · Cited by 99
Quantitative surface characterization of pulmonary nodules based on thin-section CT images
Kawata, Y., Niki, N., Ohmatsu, H., Kakinuma, R., Eguchi, K., Kaneko, M., & Moriyama, N. (1998) · IEEE Transactions on Nuclear Science · doi:10.1109/23.708321 · Cited by 86
Automated lung nodule classification following automated nodule detection on CT: A serial approach
Armato, S. G., Altman, M. B., Wilkie, J. R., Sone, S., Li, F., Doi, K., & Roy, A. S. (2003) · Medical Physics · doi:10.1118/1.1573210 · Cited by 81
Dodd, L. E., Wagner, R. F., Armato, S. G., McNitt‐Gray, M. F., Beiden, S. V., Chan, H., Gur, D., McLennan, G., Metz, C. E., Petrick, N., et al. (2004) · Academic Radiology · doi:10.1016/s1076-6332(03)00814-6 · Cited by 78
Self-citationTourassi, G. D., & Floyd, C. E. (1997) · Medical Decision Making · doi:10.1177/0272989x9701700209 · Cited by 75
National Cancer Institute Initiative
Clarke, L. P., Croft, B. Y., Staab, E. V., Baker, H., & Sullivan, D. C. (2001) · Academic Radiology · doi:10.1016/s1076-6332(03)80555-x · Cited by 51
Self-citationVariations in measured performance of CAD schemes due to database composition and scoring protocol
Nishikawa, R. M., & Yarusso, L. M. (1998) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.310894 · Cited by 40
Cited by
Armato, S. G., McLennan, G., Bidaut, L., McNitt‐Gray, M. F., Meyer, C. R., Reeves, A. P., Zhao, B., Aberle, D. R., Henschke, C. I., Hoffman, E. A., et al. (2011) · Medical Physics · doi:10.1118/1.3528204 · Cited by 2,887
Self-citationComparison and evaluation of methods for liver segmentation from CT datasets
Heimann, T., van Ginneken, B., Styner, M. A., Arzhaeva, Y., Aurich, V., Bauer, C., Beck, A., Becker, C., Beichel, R., Bekes, G., et al. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2013851 · Cited by 1,135
Diffusion models in medical imaging: A comprehensive survey
Kazerouni, A., Aghdam, E. K., Heidari, M., Azad, R., Fayyaz, M., Hacihaliloglu, I., & Merhof, D. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102846 · Cited by 765
Cheng, J.-Z., Ni, D., Chou, Y.-H., Qin, J., Tiu, C.-M., Chang, Y.-C., Huang, C.-S., Shen, D., & Chen, C.-M. (2016) · Scientific Reports · doi:10.1038/srep24454 · Cited by 755
Computer analysis of computed tomography scans of the lung: a survey
Sluimer, I., Schilham, A., Prokop, M., & van Ginneken, B. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.862753 · Cited by 556
Metadata
- Authors
- Armato III, S. G., McLennan, G., McNitt-Gray, M. F., Meyer, C. R., Yankelevitz, D., Aberle, D. R., Henschke, C. I., Hoffman, E. A., Kazerooni, E. A., MacMahon, H., Reeves, A. P., Croft, B. Y., & Clarke, L. P.
- Venue
- Radiology
- Published
- 2004-09
- Volume
- 232
- Issue
- 3
- Pages
- 739-748
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2136325898
- Cited by
- 380
- References
- 24
- FWCI
- 17.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.