The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Noninvasive Coronary Angiography with 16–Detector Row CT: Effect of Heart Rate
Abstract
PURPOSE: To evaluate the effect of heart rate on the quality of coronary angiograms obtained with 16-detector row computed tomography (CT) by using temporally enhanced three-dimensional (3D) approaches. MATERIALS AND METHODS: The local ethics committee approved the study, and informed consent was obtained from all patients. Fifty patients underwent coronary CT angiography (heart rate range, 45-103 beats per minute). Raw data from helical CT and electrocardiography (ECG) were saved in a combined data set. Retrospectively ECG-gated images were reconstructed at preselected phases (50% and 80%) of the cardiac cycle. A 3D voxel-based approach with cardiac phase weighting was used for reconstruction. Testing for correlation between heart rate, cardiac phase reconstruction window, and image quality was performed with Kruskal-Wallis analysis. Image quality (freedom from cardiac motion-related artifacts) was referenced against findings at conventional angiography in a secondary evaluation step. Regression analysis was performed to calculate heart rate thresholds for future beta-blocker application. RESULTS: A significant negative correlation was observed between heart rate and image quality (r = 0.80, P < .001). Motion artifact-free images were available for 44 (88%) patients and were achieved consistently at a heart rate of 80 or fewer beats per minute (n = 39). Best image quality was achieved at 75 or fewer beats per minute. Segmental analysis revealed that 97% of arterial segments (diameter > or = 1.5 mm according to conventional angiography) were assessable at 80 or fewer beats per minute. Premature ventricular contractions and rate-contained arrhythmia did not impede diagnostic assessment of the coronary arteries in 10 (83%) of the 12 patients affected. CONCLUSION: Motion-free coronary angiograms can be obtained consistently with 16-detector row CT scanners and adaptive multicyclic reconstruction algorithms in patients with heart rates of less than 80 beats per minute.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nieman, K., Cademartiri, F., Lemos, P. A., Raaijmakers, R., Pattynama, P. M. T., & de Feyter, P. J. (2002) · Circulation · doi:10.1161/01.cir.0000037222.58317.3d · Cited by 956
Ropers, D., Baum, U., Pohle, K., Anders, K., Ulzheimer, S., Ohnesorge, B., Schlundt, C., Bautz, W., Daniel, W. G., & Achenbach, S. (2003) · Circulation · doi:10.1161/01.cir.0000055738.31551.a9 · Cited by 930
Coronary Magnetic Resonance Angiography for the Detection of Coronary Stenoses
Kim, W. Y., Danias, P. G., Stuber, M., Flamm, S. D., Plein, S., Nagel, E., Langerak, S. E., Weber, O. M., Pedersen, E. M., Schmidt, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010866 · Cited by 903
Coronary angiography with multi-slice computed tomography
Nieman, K., Oudkerk, M., Rensing, B. J., van Ooijen, P., Munne, A., van Geuns, R.-J., & de Feyter, P. J. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04058-7 · Cited by 725
A critical review of the systolic time intervals.
Lewis, R. P., Rittogers, S. E., Froester, W. F., & Boudoulas, H. (1977) · Circulation · doi:10.1161/01.cir.56.2.146 · Cited by 624
Budoff, M. J., Georgiou, D., Brody, A., Agatston, A. S., Kennedy, J., Wolfkiel, C., Stanford, W., Shields, P., Lewis, R. J., Janowitz, W. R., et al. (1996) · Circulation · doi:10.1161/01.cir.93.5.898 · Cited by 488
Bashore, T. M., Bates, E. R., Berger, P. B., Clark, D. A., Cusma, J. T., Dehmer, G. J., Kern, M. J., Laskey, W. K., O’Laughlin, M. P., Oesterle, S., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01346-8 · Cited by 320
Wang, Y., Vidan, E., & Bergman, G. W. (1999) · Radiology · doi:10.1148/radiology.213.3.r99dc41751 · Cited by 281
Hong, C., Becker, C. R., Huber, A., Schoepf, U. J., Ohnesorge, B., Knez, A., Brüning, R., & Reiser, M. F. (2001) · Radiology · doi:10.1148/radiol.2203010055 · Cited by 255
Changes in diastolic time with various pharmacologic agents: implication for myocardial perfusion.
Boudoulas, H., Rittgers, S. E., Lewis, R. P., Leier, C. V., & Weissler, A. M. (1979) · Circulation · doi:10.1161/01.cir.60.1.164 · Cited by 206
Herzog, C., Abolmaali, N., Balzer, J. O., Baunach, S., Ackermann, H., Doğan, S., Britten, M. B., & Vogl, T. J. (2002) · European Radiology · doi:10.1007/s00330-002-1553-5 · Cited by 130
Operational definition of normal sinus heart rate
Spodick, D. H., RAJU, P. K., Bishop, R. L., & Rifkin, R. D. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)90947-w · Cited by 128
Achenbach, S. S., Giesler, T., Ropers, D., Ulzheimer, S., Anders, K., Wenkel, E., Pohle, K., Kachelrieß, M., Derlien, H., Kalender, W. A., et al. (2003) · Investigative Radiology · doi:10.1097/00004424-200302000-00007 · Cited by 102
Adaptive temporal resolution optimization in helical cardiac cone beam CT reconstruction
Manzke, R., Graß, M., Nielsen, T., Shechter, G., & Hawkes, D. J. (2003) · Medical Physics · doi:10.1118/1.1624756 · Cited by 97
Self-citationAchenbach, S. S., Moshage, W. E. L., Ropers, D., & Bachmann, K. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.4.9530029 · Cited by 97
Heuschmid, M., Küttner, A., Flohr, T. G., Wildberger, J. E., Lell, M., Kopp, A. F., Schröder, S., Baum, U., Schaller, S., Hartung, A., et al. (2002) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-2002-32227 · Cited by 49
Cited by
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Abbara, S., Arbab-Zadeh, A., Callister, T. Q., Desai, M. Y., Mamuya, W., Thomson, L., & Weigold, W. G. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.03.004 · Cited by 580
Lancellotti, P., Pibarot, P., Chambers, J., Edvardsen, T., Delgado, V., Dulgheru, R., Pepi, M., Cosyns, B., Dweck, M. R., Garbi, M., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jew025 · Cited by 567
Noninvasive Coronary Angiography With Multislice Computed Tomography
Hoffmann, M. H. K. (2005) · JAMA · doi:10.1001/jama.293.20.2471 · Cited by 507
Self-citationSCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
Halliburton, S. S., Abbara, S., Chen, M. Y., Gentry, R., Mahesh, M., Raff, G. L., Shaw, L. J., & Hausleiter, J. (2011) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2011.06.001 · Cited by 491
Metadata
- Authors
- Hoffmann, M. H. K., Shi, H., Manzke, R., Schmid, F. T., De Vries, L., Grass, M., Brambs, H.-J., & Aschoff, A. J.
- Venue
- Radiology
- Published
- 2005-01
- Volume
- 234
- Issue
- 1
- Pages
- 86-97
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2130519322
- Cited by
- 264
- References
- 16
- FWCI
- 31.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.