CoChat

Appropriateness of a Donor Liver with Respect to Macrosteatosis: Application of Artificial Neural Networks to US Images—Initial Experience

Kim, Se Hyung, Lee, Jeong Min, Kim, Jong Hyo, Kim, Kwang Gi, Han, Joon Koo, Lee, Kyoung Ho, Park, Seong Ho, Yi, Nam-Joon, Suh, Kyung-Suk, An, Su Kyung, Kim, Young Jun, Son, Kyu Ri, Lee, Hye Seung, Choi, Byung Ihn · 2005 · Radiology
Cited by 81

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

PURPOSE: To retrospectively compare performance of artificial neural networks (ANNs) applied to ultrasonographic (US) images with that of radiologists for prediction of appropriateness of a donor liver with respect to macrosteatosis before liver transplantation. MATERIALS AND METHODS: Institutional ethics committee approved study; written informed consent was obtained. ANNs, constructed with three-layered 15-neuron back-propagation algorithm, were trained to predict appropriateness of a donor liver with respect to macrosteatosis by using statistically significant laboratory and US parameters derived from univariate analyses, together with correct diagnosis. Input variables for ANNs were alkaline phosphatase, glutamic oxaloacetic transaminase, glutamic pyruvate transaminase, gamma-glutamyltransferase, hepatorenal ratio of echogenicity, and tail area ratio and tail length of portal vein wall echogenicity. Three radiologists graded US images in 94 potential donors (71 men and 23 women) on the basis of four degrees of hepatic steatosis. After training and testing of ANNs, performance of ANNs and radiologists in predicting appropriateness of potential donors was evaluated with receiver operating characteristic (ROC) analysis and compared by means of univariate z score test. RESULTS: Among 94 potential donor livers, 76 were normal or had mild steatosis, and 18 had moderate or severe macrosteatosis at histopathologic examination. Area under ROC curve (Az) of ANNs (Az=0.9673) was significantly greater than that of radiologists (faculty, Az=0.9106, P=.048; fellow, Az= 0.9038, P=.044; resident, Az=0.8931, P=.038). No statistically significant difference in sensitivity for predicting appropriateness as a liver donor with respect to macrosteatosis was found between ANNs (88.9%) and radiologists (P >.05). However, specificity of ANNs (96.1%) was significantly better than that of radiologists (P <.003). CONCLUSION: ANNs might be a useful tool to categorize whether a donor liver is appropriate for transplantation with respect to macrosteatosis on the basis of multiple variables related to laboratory and US features. Further study is needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2343040142

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 81

Metadata

Authors
Kim, S. H., Lee, J. M., Kim, J. H., Kim, K. G., Han, J. K., Lee, K. H., Park, S. H., Yi, N.-J., Suh, K.-S., An, S. K., Kim, Y. J., Son, K. R., Lee, H. S., & Choi, B. I.
Venue
Radiology
Published
2005-03
Volume
234
Issue
3
Pages
793-803
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2121707410
Cited by
81
References
1
FWCI
2.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Appropriateness of a Donor Liver with Respect to Macrosteatosis: Application of Artificial Neural Networks to US Images—Initial Experience. https://app.cochat.ai/papers/10.1148/radiol.2343040142
The paper
Kim, S. H., Lee, J. M., Kim, J. H., Kim, K. G., Han, J. K., Lee, K. H., Park, S. H., Yi, N.-J., Suh, K.-S., An, S. K., Kim, Y. J., Son, K. R., Lee, H. S., & Choi, B. I. (2005). Appropriateness of a Donor Liver with Respect to Macrosteatosis: Application of Artificial Neural Networks to US Images—Initial Experience. Radiology. https://doi.org/10.1148/radiol.2343040142

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.