Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 516

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Intracortical Lesions in Multiple Sclerosis: Improved Detection with 3D Double Inversion-Recovery MR Imaging

Open access
Geurts, Jeroen J. G., Pouwels, Petra J. W., Uitdehaag, Bernard M. J., Polman, Chris H., Barkhof, Frederik, Castelijns, Jonas A.·2005·Radiology

Abstract

PURPOSE: To prospectively compare the depiction of intracortical lesions by using multislab three-dimensional (3D) double inversion-recovery (DIR), multislab 3D fluid-attenuated inversion-recovery (FLAIR), and T2-weighted spin-echo (SE) magnetic resonance (MR) imaging in patients with multiple sclerosis. MATERIALS AND METHODS: Local ethics review board approval and informed consent were obtained. Conventional T2-weighted SE and multislab 3D FLAIR and DIR images were acquired in 10 patients with multiple sclerosis (five women, five men) and 11 age-matched healthy control subjects (seven women, four men). Mean age was 40 years (range, 25-54 years) in patients and 34 years (range, 24-55 years) in control subjects. Lesions were classified according to seven anatomic regions: intracortical, mixed white matter-gray matter, juxtacortical, deep gray matter, periventricular white matter, deep white matter, and infratentorial lesions. The numbers of lesions per category were compared between techniques (Dunnett-corrected analysis of variance). Gain or loss (with 95% confidence intervals [CIs]) of numbers of lesions detected at 3D DIR imaging was calculated in comparison with those detected at T2-weighted SE and 3D FLAIR imaging. RESULTS: Total number of lesions did not differ between 3D DIR and 3D FLAIR sequences, but the 3D DIR sequence showed a gain of 21% (95% CI: 4%, 41%) in comparison with the T2-weighted SE sequence. Because of high gray matter-white matter contrast, DIR images depicted more intracortical lesions (80 lesions in 10 patients) than both SE (10 lesions) and FLAIR (31 lesions) images; gains with DIR were 538% (95% CI: 191%, 1297%) and 152% (95% CI: 15%, 453%) compared with SE and FLAIR, respectively. Only four intracortical lesions were detected in control subjects. Also, DIR imaging enabled a better definition of mixed white matter-gray matter lesions because of greater contrast between the lesion and its surroundings. CONCLUSION: MR imaging with 3D DIR enables increased intracortical lesion detection in the multiple sclerosis brain, as well as improved distinction between juxtacortical and white matter-gray matter lesions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2361040450

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

See all 516

Metadata

Authors
Geurts, J. J. G., Pouwels, P. J. W., Uitdehaag, B. M. J., Polman, C. H., Barkhof, F., & Castelijns, J. A.
Venue
Radiology
Published
2005-07
Volume
236
Issue
1
Pages
254-260
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2152674393
Cited by
516
References
30
FWCI
11.15
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intracortical Lesions in Multiple Sclerosis: Improved Detection with 3D Double Inversion-Recovery MR Imaging. https://app.cochat.ai/papers/10.1148/radiol.2361040450
The paper
Geurts, J. J. G., Pouwels, P. J. W., Uitdehaag, B. M. J., Polman, C. H., Barkhof, F., & Castelijns, J. A. (2005). Intracortical Lesions in Multiple Sclerosis: Improved Detection with 3D Double Inversion-Recovery MR Imaging. Radiology. https://doi.org/10.1148/radiol.2361040450

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.