CoChat

Intramyocellular Lipid Quantification: Repeatability with1H MR Spectroscopy

Torriani, Martin, Thomas, Bijoy J., Halpern, Elkan F., Jensen, Megan E., Rosenthal, Daniel I., Palmer, William E. · 2005 · Radiology
Cited by 64

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

PURPOSE: To prospectively determine the repeatability and variability of tibialis anterior intramyocellular lipid (IMCL) quantifications performed by using 1.5-T hydrogen 1 (1H) magnetic resonance (MR) spectroscopy in healthy subjects. MATERIALS AND METHODS: Institutional review board approval and written informed consent were obtained for this Health Insurance Portability and Accountability Act-compliant study. The authors examined the anterior tibial muscles of 27 healthy subjects aged 19-48 years (12 men, 15 women; mean age, 25 years) by using single-voxel short-echo-time point-resolved 1H MR spectroscopy. During a first visit, the subjects underwent 1H MR spectroscopy before and after being repositioned in the magnet bore, with voxels carefully placed on the basis of osseous landmarks. Measurements were repeated after a mean interval of 12 days. All spectra were fitted by using Java-based MR user interface (jMRUI) and LCModel software, and lipid peaks were scaled to the unsuppressed water peak (at 4.7 ppm) and the total creatine peak (at approximately 3.0 ppm). A one-way random-effects variance components model was used to determine intraday and intervisit coefficients of variation (CVs). A power analysis was performed to determine the detectable percentage change in lipid measurements for two subject sample sizes. RESULTS: Measurements of the IMCL methylene protons peak at a resonance of 1.3 ppm scaled to the unsuppressed water peak (IMCL(W)) that were obtained by using jMRUI software yielded the lowest CVs overall (intraday and intervisit CVs, 13.4% and 14.4%, respectively). The random-effects variance components model revealed that nonbiologic factors (equipment and repositioning) accounted for 50% of the total variability in IMCL quantifications. Power analysis for a sample size of 20 subjects revealed that changes in IMCL(W) of greater than 15% could be confidently detected between 1H MR spectroscopic measurements obtained on different days. CONCLUSION: 1H MR spectroscopy is feasible for repeatable quantification of IMCL concentrations in longitudinal studies of muscle metabolism.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2362041661

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 64

Metadata

Authors
Torriani, M., Thomas, B. J., Halpern, E. F., Jensen, M. E., Rosenthal, D. I., & Palmer, W. E.
Venue
Radiology
Published
2005-08
Volume
236
Issue
2
Pages
609-614
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2043704984
Cited by
64
References
8
FWCI
3.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intramyocellular Lipid Quantification: Repeatability with1H MR Spectroscopy. https://app.cochat.ai/papers/10.1148/radiol.2362041661
The paper
Torriani, M., Thomas, B. J., Halpern, E. F., Jensen, M. E., Rosenthal, D. I., & Palmer, W. E. (2005). Intramyocellular Lipid Quantification: Repeatability with1H MR Spectroscopy. Radiology. https://doi.org/10.1148/radiol.2362041661

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.