Radiation Dose Reduction without Degradation of Low-Contrast Detectability at Abdominal Multisection CT with a Low–Tube Voltage Technique: Phantom Study

Funama, Yoshinori, Awai, Kazuo, Nakayama, Yoshiharu, Kakei, Kiyotaka, Nagasue, Nozomu, Shimamura, Masamichi, Sato, Natsuko, Sultana, Shamima, Morishita, Shoji, Yamashita, Yasuyuki·2005·Radiology

Abstract

PURPOSE: To reduce radiation dose from abdominal computed tomography (CT) without degradation of low-contrast detectability by using a technique with low tube voltage (90 kV). MATERIALS AND METHODS: The institutional review board approved the participation of the radiologists in the observer performance test, and informed consent was obtained from all participating radiologists. A phantom for measurement of the radiation dose and a phantom containing low-contrast objects were scanned with a 16-detector row CT scanner at 120 kV and 90 kV. For determination of the radiation dose at both 90 kV and 120 kV, the tube current-time product settings were 100-560 mAs, and the doses at the center and periphery of the phantom were measured. To assess low-contrast detectability, we used a 300-mAs setting at 120 kV and 250-560-mAs settings at 90 kV. Five observers participated in the receiver operating characteristic analysis. Area under the receiver operating characteristic curve (A(z)) values were calculated in each observer. A(z) values obtained with each of the scanning techniques were recorded, and differences were examined for significance by using the Dunnet method. RESULTS: The mean A(z) value was 0.951 at 120 kV and 300 mAs. A(z) values were 0.927-0.973 at 90 kV and 450-560 mAs, and the differences between those values and values obtained at 120 kV and 300 mAs were not significant (P = .937-.952). A value of 100% was assigned to the radiation dose delivered to the center of the phantom at 120 kV and 300 mAs. The relative dose delivered at 90 kV ranged from 65% at 450 mAs to 79% at 560 mAs. CONCLUSION: A reduction from 120 kV to 90 kV led to as much as a 35% reduction in the radiation dose, without sacrifice of low-contrast detectability, at CT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2373041643

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 226

Metadata

Authors
Funama, Y., Awai, K., Nakayama, Y., Kakei, K., Nagasue, N., Shimamura, M., Sato, N., Sultana, S., Morishita, S., & Yamashita, Y.
Venue
Radiology
Published
2005-12
Volume
237
Issue
3
Pages
905-910
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1985171971
Cited by
226
References
2
FWCI
3.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Radiation Dose Reduction without Degradation of Low-Contrast Detectability at Abdominal Multisection CT with a Low–Tube Voltage Technique: Phantom Study. https://app.cochat.ai/papers/10.1148/radiol.2373041643
The paper
Funama, Y., Awai, K., Nakayama, Y., Kakei, K., Nagasue, N., Shimamura, M., Sato, N., Sultana, S., Morishita, S., & Yamashita, Y. (2005). Radiation Dose Reduction without Degradation of Low-Contrast Detectability at Abdominal Multisection CT with a Low–Tube Voltage Technique: Phantom Study. Radiology. https://doi.org/10.1148/radiol.2373041643

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.