The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
CT Colonography in the Detection of Colorectal Polyps and Cancer: Systematic Review, Meta-Analysis, and Proposed Minimum Data Set for Study Level Reporting
Abstract
PURPOSE: To assess the methodologic quality of available data in published reports of computed tomographic (CT) colonography by performing systematic review and meta-analysis. MATERIALS AND METHODS: The MEDLINE database was searched for colonography reports published between 1994 and 2003, without language restriction. The terms colonography, colography, CT colonoscopy, CT pneumocolon, virtual colonoscopy, and virtual endoscopy were used. Studies were selected if the focus was detection of colorectal polyps verified with within-subject reference colonoscopy by using key methodologic criteria based on information presented at the Fourth International Symposium on Virtual Colonoscopy (Boston, Mass). Two reviewers independently abstracted methodologic characteristics. Per-patient and per-polyp detection rates were extracted, and authors were contacted, when necessary. Per-patient sensitivity and specificity were calculated for different lesion size categories, and Forest plots were produced. Meta-analysis of paired sensitivity and specificity was conducted by using a hierarchical model that enabled estimation of summary receiver operating characteristic curves allowing for variation in diagnostic threshold, and the average operating point was calculated. Per-polyp sensitivity was also calculated. RESULTS: Of 1398 studies considered for inclusion, 24 met our criteria. There were 4181 patients with a study prevalence of abnormality of 15%-72%. Meta-analysis of 2610 patients, 206 of whom had large polyps, showed high per-patient average sensitivity (93%; 95% confidence interval [CI]: 73%, 98%) and specificity (97%; 95% CI: 95%, 99%) for colonography; sensitivity and specificity decreased to 86% (95% CI: 75%, 93%) and 86% (95% CI: 76%, 93%), respectively, when the threshold was lowered to include medium polyps. When polyps of all sizes were included, studies were too heterogeneous in sensitivity (range, 45%-97%) and specificity (range, 26%-97%) to allow meaningful meta-analysis. Of 150 cancers, 144 were detected (sensitivity, 95.9%; 95% CI: 91.4%, 98.5%). Data reporting was frequently incomplete, with no generally accepted format. CONCLUSION: CT colonography seems sufficiently sensitive and specific in the detection of large and medium polyps; it is especially sensitive in the detection of symptomatic cancer. Studies are poorly reported, however, and the authors propose a minimum data set for study reporting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Computed Tomographic Virtual Colonoscopy to Screen for Colorectal Neoplasia in Asymptomatic Adults
Pickhardt, P. J., Choi, J. R., Hwang, I., Butler, J. A., Puckett, M. L., Hildebrandt, H. A., Wong, R. K., Nugent, P. A., Mysliwiec, P. A., & Schindler, W. R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa031618 · Cited by 1,972
Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies
Rex, D., Cutler, C., Lemmel, G., Rahmani, E., Clark, D., Helper, D., Lehman, G., & Mark, D. (1997) · Gastroenterology · doi:10.1016/s0016-5085(97)70214-2 · Cited by 1,553
Systematic reviews of evaluations of diagnostic and screening tests
Deeks, J. J. (2001) · BMJ · doi:10.1136/bmj.323.7305.157 · Cited by 1,340
Self-citationGuidelines for Meta-analyses Evaluating Diagnostic Tests
Irwig, L., Tosteson, A. N. A., Gatsonis, C., Lau, J., Colditz, G., Chalmers, T. C., & Mosteller, F. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-8-199404150-00008 · Cited by 753
A Comparison of Virtual and Conventional Colonoscopy for the Detection of Colorectal Polyps
Fenlon, H. M., Nunes, D. P., Schroy, P. C., Barish, M. A., Clarke, P. D., & Ferrucci, J. T. (1999) · New England Journal of Medicine · doi:10.1056/nejm199911113412003 · Cited by 746
Cotton, P. B., Durkalski, V. L., Pineau, B. C., Palesch, Y. Y., Mauldin, P. D., Hoffman, B., Vining, D. J., Small, W. C., Affronti, J., Rex, D., et al. (2004) · JAMA · doi:10.1001/jama.291.14.1713 · Cited by 673
Cited by
Levin, B., Lieberman, D. A., McFarland, B., Andrews, K. S., Brooks, D., Bond, J., Dash, C., Giardiello, F. M., Glick, S., Johnson, D., et al. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.02.002 · Cited by 2,990
Levin, B., Lieberman, D. A., McFarland, B., Smith, R. A., Brooks, D., Andrews, K. S., Dash, C., Giardiello, F. M., Glick, S., Levin, T. R., et al. (2008) · CA: A Cancer Journal for Clinicians · doi:10.3322/ca.2007.0018 · Cited by 1,801
Cunningham, D., Atkin, W., Lenz, H.-J., Lynch, H. T., Minsky, B., Nordlinger, B., & Starling, N. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60353-4 · Cited by 1,351
Self-citationACG Clinical Guidelines: Colorectal Cancer Screening 2021
Shaukat, A., Kahi, C. J., Burke, C. A., Rabeneck, L., Sauer, B. G., & Rex, D. K. (2021) · American Journal of Gastroenterology · doi:10.14309/ajg.0000000000001122 · Cited by 853
Vanhoenacker, P. K., Heijenbrok-Kal, M. H., Van Heste, R., Decramer, I., Van Hoe, L. R., Wijns, W., & Hunink, M. G. M. (2007) · Radiology · doi:10.1148/radiol.2442061218 · Cited by 442
Metadata
- Authors
- Halligan, S., Altman, D. G., Taylor, S. A., Mallett, S., Deeks, J. J., Bartram, C. I., & Atkin, W.
- Venue
- Radiology
- Published
- 2005-12
- Volume
- 237
- Issue
- 3
- Pages
- 893-904
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2107348187
- Cited by
- 382
- References
- 27
- FWCI
- 2.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CT Colonography in the Detection of Colorectal Polyps and Cancer: Systematic Review, Meta-Analysis, and Proposed Minimum Data Set for Study Level Reporting. https://app.cochat.ai/papers/10.1148/radiol.2373050176
- The paper
- Halligan, S., Altman, D. G., Taylor, S. A., Mallett, S., Deeks, J. J., Bartram, C. I., & Atkin, W. (2005). CT Colonography in the Detection of Colorectal Polyps and Cancer: Systematic Review, Meta-Analysis, and Proposed Minimum Data Set for Study Level Reporting. Radiology. https://doi.org/10.1148/radiol.2373050176
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.