Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 224

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Leukocyte DNA Damage after Multi–Detector Row CT: A Quantitative Biomarker of Low-Level Radiation Exposure

Rothkamm, Kai, Balroop, Sheena, Shekhdar, Jane, Fernie, Patricia, Goh, Vicky·2007·Radiology

Abstract

PURPOSE: To prospectively determine if gammaH2AX (phosphorylated form of H2AX histone variant)-based visualization and quantification of DNA damage induced in peripheral blood mononuclear cells (PBMCs) can be used to estimate the radiation dose received by adult patients who undergo multidetector computed tomography (CT). MATERIALS AND METHODS: After institutional review board approval and written informed patient consent were obtained, eight women and five men (mean age, 63.8 years) who would be undergoing chest-abdominal-pelvic CT or chest CT only were recruited. Venous blood samples obtained before scanning were exposed to different radiation doses in vitro and incubated for 5-30 minutes to obtain reference values of gammaH2AX focus yield. Additional blood samples were taken 5-30 minutes after CT. Leukocytes were isolated, fixed, and stained for gammaH2AX expression. The gammaH2AX focus yields were determined with fluorescence microscopy, and the radiation doses delivered during CT were estimated by comparing post-CT focus yields with in vitro pre-CT focus yields. These CT radiation doses were compared with doses calculated by using phantom dosimetry and Monte Carlo data sets. Data were analyzed by using linear regression, the dispersion index test, and the contaminated Poisson method. RESULTS: Compared with the gammaH2AX focus yields in blood samples taken before CT (0.06 focus per cell+/-0.01 [mean+/-standard error of mean]), the yields in blood samples taken 5 minutes after chest-abdominal-pelvic CT (0.52 focus per cell+/-0.02) were 8-10-fold higher and corresponded to a mean radiation dose of 16.4 mGy (95% confidence interval: 15.1, 17.7). The mean yield of 0.24 focus per cell+/-0.04 in one patient after chest CT corresponded to a mean radiation dose of 6.3 mGy+/-1.4. In comparison, phantom dosimetry-calculated total blood doses were 13.85 mGy with whole-body CT and 5.16 mGy with chest CT. CONCLUSION: gammaH2AX focus yield in blood cells may be a useful quantitative biomarker of human low-level radiation exposure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2421060171

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 224

Metadata

Authors
Rothkamm, K., Balroop, S., Shekhdar, J., Fernie, P., & Goh, V.
Venue
Radiology
Published
2007-01
Volume
242
Issue
1
Pages
244-251
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2168367012
Cited by
224
References
2
FWCI
8.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Leukocyte DNA Damage after Multi–Detector Row CT: A Quantitative Biomarker of Low-Level Radiation Exposure. https://app.cochat.ai/papers/10.1148/radiol.2421060171
The paper
Rothkamm, K., Balroop, S., Shekhdar, J., Fernie, P., & Goh, V. (2007). Leukocyte DNA Damage after Multi–Detector Row CT: A Quantitative Biomarker of Low-Level Radiation Exposure. Radiology. https://doi.org/10.1148/radiol.2421060171

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.