Intracranial Aneurysms: Treatment with Bare Platinum Coils—Aneurysm Packing, Complex Coils, and Angiographic Recurrence
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
PURPOSE: To retrospectively assess, with three-dimensional rotational angiography, the relationship between packing, complex coils, and angiographic recurrence of aneurysms treated with coils. MATERIALS AND METHODS: Informed consent was waived by the institutional review board that approved the study. Results at follow-up angiography of 255 aneurysms in 223 patients (161 female and 62 male patients; mean age, 48 years) were dichotomized into presence or absence of recurrence. The degree of packing of aneurysms treated with complex coils alone, with complex and helical coils, and with helical coils only was compared for significant differences. With generalized estimating equations analysis, relative risk (RR) for recurrence was calculated for mode of manifestation, duration of follow-up, aneurysm volume, packing, initial angiographic result, percentage of complex coils, aneurysm location, and multiplicity of aneurysms. RESULTS: Follow-up angiography revealed recurrence in 28.6% of aneurysms at a mean follow-up of 12 months; 5.5% were amenable to re-treatment. Aneurysms treated with complex and those treated with helical coils only had a mean packing of 27% and 26%, respectively. There was no significant difference between packing of aneurysms treated with complex and those treated with helical coils (P = .538). Recurring and stable aneurysms both had a mean packing of 27%. Generalized estimating equations analysis showed significant differences between duration of follow-up and recurrence (P = .001, RR = 3.39), between aneurysm volume and recurrence (P < .001, RR = 6.15), and between hemorrhagic manifestation and recurrence (P = .002, RR = 3.17). There was no significant difference between packing and recurrence, between initial angiographic result and recurrence, between percentage of complex coils and recurrence, between aneurysm location and recurrence, or between multiplicity of aneurysms and recurrence. CONCLUSION: More angiographic recurrences are detected over time. Complex coils do not augment aneurysm packing. Packing is not related to protection against recurrence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wiebers, D. O. (2003) · The Lancet · doi:10.1016/s0140-6736(03)13860-3 · Cited by 3,905
Molyneux, A. J., Kerr, R. S., Yu, L.-M., Clarke, M., Sneade, M., Yarnold, J. A., & Sandercock, P. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67214-5 · Cited by 2,886
Prevalence and Risk of Rupture of Intracranial Aneurysms: A Systematic Review
Rinkel, G. J. E., Djibuti, M., Algra, A., & van Gijn, J. (1998) · Stroke · doi:10.1161/01.str.29.1.251 · Cited by 1,512
Raymond, J., Guilbert, F., Weill, A., Georganos, S. A., Juravsky, L., Lambert, A., Lamoureux, J., Chagnon, M., & Roy, D. (2003) · Stroke · doi:10.1161/01.str.0000073841.88563.e9 · Cited by 1,496
Sluzewski, M., van Rooij, W. J., Slob, M. J., Bescós, J. O., Slump, C. H., & Wijnalda, D. (2004) · Radiology · doi:10.1148/radiol.2313030460 · Cited by 404
Kawanabe, Y., Sadato, A., Taki, W., & Hashimoto, N. (2001) · Acta Neurochirurgica · doi:10.1007/s007010170073 · Cited by 229
Tamatani, S., Ito, Y., Abe, H., Koike, T., Takeuchi, S., & Tanaka, R. (2002) · PubMed Central · Cited by 222
A multicenter study of 705 ruptured intracranial aneurysms treated with Guglielmi detachable coils.
Gallas, S., Pasco, A., Cottier, J., Gabrillargues, J., Drouineau, J., Cognard, C., & Herbreteau, D. (2005) · PubMed Central · Cited by 217
Sluzewski, M., van Rooij, W. J., Rinkel, G. J. E., & Wijnalda, D. (2003) · Radiology · doi:10.1148/radiol.2273020656 · Cited by 193
The relation between packing and reopening in coiled intracranial aneurysms: a prospective study
Slob, M. J., Sluzewski, M., & van Rooij, W. J. (2005) · Neuroradiology · doi:10.1007/s00234-005-1446-9 · Cited by 89
Cited by
Ferns, S. P., Sprengers, M. E. S., van Rooij, W. J., Rinkel, G. J. E., van Rijn, J. C., Bipat, S., Sluzewski, M., & Majoie, C. B. L. M. (2009) · Stroke · doi:10.1161/strokeaha.109.553099 · Cited by 455
Metadata
- Authors
- Piotin, M., Spelle, L., Mounayer, C., Salles-Rezende, M. T., Giansante-Abud, D., Vanzin-Santos, R., & Moret, J.
- Venue
- Radiology
- Published
- 2007-05
- Volume
- 243
- Issue
- 2
- Pages
- 500-508
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2138123546
- Cited by
- 170
- References
- 14
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intracranial Aneurysms: Treatment with Bare Platinum Coils—Aneurysm Packing, Complex Coils, and Angiographic Recurrence. https://app.cochat.ai/papers/10.1148/radiol.2431060006
- The paper
- Piotin, M., Spelle, L., Mounayer, C., Salles-Rezende, M. T., Giansante-Abud, D., Vanzin-Santos, R., & Moret, J. (2007). Intracranial Aneurysms: Treatment with Bare Platinum Coils—Aneurysm Packing, Complex Coils, and Angiographic Recurrence. Radiology. https://doi.org/10.1148/radiol.2431060006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.