The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Coronary Artery Calcium: A Multi-institutional, Multimanufacturer International Standard for Quantification at Cardiac CT
Abstract
PURPOSE: To develop a consensus standard for quantification of coronary artery calcium (CAC). MATERIALS AND METHODS: A standard for CAC quantification was developed by a multi-institutional, multimanufacturer international consortium of cardiac radiologists, medical physicists, and industry representatives. This report specifically describes the standardization of scan acquisition and reconstruction parameters, the use of patient size-specific tube current values to achieve a prescribed image noise, and the use of the calcium mass score to eliminate scanner- and patient size-based variations. An anthropomorphic phantom containing calibration inserts and additional phantom rings were used to simulate small, medium-size, and large patients. The three phantoms were scanned by using the recommended protocols for various computed tomography (CT) systems to determine the calibration factors that relate measured CT numbers to calcium hydroxyapatite density and to determine the tube current values that yield comparable noise values. Calculation of the calcium mass score was standardized, and the variance in Agatston, volume, and mass scores was compared among CT systems. RESULTS: Use of the recommended scanning parameters resulted in similar noise for small, medium-size, and large phantoms with all multi-detector row CT scanners. Volume scores had greater interscanner variance than did Agatston and calcium mass scores. Use of a fixed calcium hydroxyapatite density threshold (100 mg/cm(3)), as compared with use of a fixed CT number threshold (130 HU), reduced interscanner variability in Agatston and calcium mass scores. With use of a density segmentation threshold, the calcium mass score had the smallest variance as a function of patient size. CONCLUSION: Standardized quantification of CAC yielded comparable image noise, spatial resolution, and mass scores among different patient sizes and different CT systems and facilitated reduced radiation dose for small and medium-size patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786
Wexler, L., Brundage, B., Crouse, J., Detrano, R., Fuster, V., Maddahi, J., Rumberger, J., Stanford, W., White, R., & Taubert, K. (1996) · Circulation · doi:10.1161/01.cir.94.5.1175 · Cited by 1,070
Self-citationRaggi, P., Callister, T. Q., Cooil, B., He, Z.-X., Lippolis, N. J., Russo, D. J., Zelinger, A., & Mahmarian, J. J. (2000) · Circulation · doi:10.1161/01.cir.101.8.850 · Cited by 835
Callister, T. Q., Cooil, B., Raya, S. P., Lippolis, N. J., Russo, D. J., & Raggi, P. (1998) · Radiology · doi:10.1148/radiology.208.3.9722864 · Cited by 750
Prediction of coronary events with electron beam computed tomography
Arad, Y., Spadaro, L. A., Goodman, K., Newstein, D., & Guerci, A. D. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00872-x · Cited by 744
ECG‐correlated image reconstruction from subsecond multi‐slice spiral CT scans of the heart
Kachelrieß, M., Ulzheimer, S., & Kalender, W. A. (2000) · Medical Physics · doi:10.1118/1.1286552 · Cited by 225
Self-citationOhnesorge, B., Flohr, T., Fischbach, R., Kopp, A., Knez, A., Schröder, S., Schöpf, U., Crispin, A., Klotz, E., Reiser, M., et al. (2002) · European Radiology · doi:10.1007/s00330-002-1394-2 · Cited by 185
Assessment of calcium scoring performance in cardiac computed tomography
Ulzheimer, S., & Kalender, W. A. (2003) · European Radiology · doi:10.1007/s00330-002-1746-y · Cited by 177
Self-citationWang, S., Detrano, R., Secci, A., Tang, W., Doherty, T. M., Puentes, G., Wong, N. D., & Brundage, B. H. (1996) · American Heart Journal · doi:10.1016/s0002-8703(96)90237-9 · Cited by 142
Reproducibility of the measurement of coronary calcium with ultrafast computed tomography
Devries, S. R., Wolfkiel, C. J., Shah, V. T., Chomka, E. V., & Rich, S. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80706-1 · Cited by 133
Cited by
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Self-citationRevised microcalcification hypothesis for fibrous cap rupture in human coronary arteries
Kelly-Arnold, A., Maldonado, N., Laudier, D., Aikawa, E., Cardoso, L., & Weinbaum, S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1308814110 · Cited by 356
Wolterink, J. M., Leiner, T., de Vos, B. D., van Hamersvelt, R. W., Viergever, M. A., & Išgum, I. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.04.004 · Cited by 321
Perrone-Filardi, P., Achenbach, S., Möhlenkamp, S., Reiner, Z., Sambuceti, G., Schuijf, J. D., Van der Wall, E., Kaufmann, P. A., Knuuti, J., Schroeder, S., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq235 · Cited by 149
Gennari, A. G., Rossi, A., De Cecco, C. N., van Assen, M., Sartoretti, T., Giannopoulos, A. A., Schwyzer, M., Huellner, M. W., & Messerli, M. (2024) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-024-03080-4 · Cited by 16
Metadata
- Authors
- McCollough, C. H., Ulzheimer, S., Halliburton, S. S., Shanneik, K., White, R. D., & Kalender, W. A.
- Venue
- Radiology
- Published
- 2007-05
- Volume
- 243
- Issue
- 2
- Pages
- 527-538
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2131036255
- Cited by
- 321
- References
- 13
- FWCI
- 12.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coronary Artery Calcium: A Multi-institutional, Multimanufacturer International Standard for Quantification at Cardiac CT. https://app.cochat.ai/papers/10.1148/radiol.2432050808
- The paper
- McCollough, C. H., Ulzheimer, S., Halliburton, S. S., Shanneik, K., White, R. D., & Kalender, W. A. (2007). Coronary Artery Calcium: A Multi-institutional, Multimanufacturer International Standard for Quantification at Cardiac CT. Radiology. https://doi.org/10.1148/radiol.2432050808
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.