Liver Fibrosis: Noninvasive Assessment with MR Elastography versus Aspartate Aminotransferase–to-Platelet Ratio Index
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
PURPOSE: To prospectively compare the sensitivity and specificity of magnetic resonance (MR) elastography with those of the routinely available aspartate aminotransferase-to-platelet ratio index (APRI) test for staging hepatic fibrosis in patients who have undergone liver biopsy for suspicion of chronic liver disease, with histopathologic examination as the reference standard. MATERIALS AND METHODS: The study was approved by the ethics committee. All patients gave written informed consent. Eighty-eight patients (37 men, 51 women; mean age, 54.0 years +/- 13.1 [standard deviation]) who underwent liver biopsy for suspicion of chronic liver disease underwent MR elastography and APRI testing within 2 days after liver biopsy. At histopathologic examination, the fibrosis stage was assessed according to METAVIR scores (fibrosis scores F0 [no fibrosis] to F4 [cirrhosis]). MR elastography was performed by transmitting mechanical waves within the liver and measuring the small cyclic displacement of the liver spins with a phase-contrast spin-echo sequence. The performances of MR elastography and APRI testing were assessed, and the optimal cutoff values for fibrosis stage were determined with receiver operating characteristic (ROC) curve analysis. RESULTS: At MR elastography, areas under the ROC curves (A(z)) for elasticity and viscosity, respectively, were 0.999 and 0.863 at fibrosis scores greater than or equal to F2, 0.997 and 0.962 at scores greater than or equal to F3, and 1.000 and 0.986 at score F4. A(z) values for elasticity at MR were significantly larger than those for the APRI (0.854 at scores > or = F2, P < .001; 0.886 at scores > or = F3, P = .003; and 0.851 at score F4, P = .004). Optimal cutoff values of elasticity were 2.5 kPa for fibrosis scores greater than or equal to F2, 3.1 kPa for scores greater than or equal to F3, and 4.3 kPa for score F4. CONCLUSION: Large A(z) values for elasticity (>0.990 for scores > or = F2, > or = F3, and F4) show that MR elastography was accurate in liver fibrosis staging and superior to biochemical testing with APRIs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Management of Hepatocellular Carcinoma *
Bruix, J., & Sherman, M. (2005) · Hepatology · doi:10.1002/hep.20933 · Cited by 5,857
Bataller, R., & Brenner, D. A. (2005) · Journal of Clinical Investigation · doi:10.1172/jci24282 · Cited by 4,958
Wai, C.-T., Greenson, J. K., Fontana, R. J., Kalbfleisch, J. D., Marrero, J. A., Conjeevaram, H. S., & Lok, A. S.-F. (2003) · Hepatology · doi:10.1053/jhep.2003.50346 · Cited by 4,406
An Algorithm for the Grading of Activity in Chronic Hepatitis C
Bedossa, P., & Poynard, T. (1996) · Hepatology · doi:10.1002/hep.510240201 · Cited by 4,088
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Castéra, L., Vergniol, J., Foucher, J., Le Bail, B., Chanteloup, E., Haaser, M., Darriet, M., Couzigou, P., & de Lédinghen, V. (2005) · Gastroenterology · doi:10.1053/j.gastro.2004.11.018 · Cited by 2,487
Sampling Variability of Liver Fibrosis in Chronic Hepatitis C
Bedossa, P., Dargère, D., & Paradis, V. (2003) · Hepatology · doi:10.1016/j.hep.2003.09.022 · Cited by 2,376
Sampling error and intraobserver variation in liver biopsy in patients with chronic HCV infection
Regev, A., Berho, M. E., Jeffers, L. J., Milikowski, C., Molina, E. G., Pyrsopoulos, N., Feng, Z.-Z., Reddy, K. R., & Schiff, E. R. (2002) · The American Journal of Gastroenterology · doi:10.1016/s0002-9270(02)04396-4 · Cited by 2,093
Bravo, A. A., Sheth, S. G., & Chopra, S. (2001) · New England Journal of Medicine · doi:10.1056/nejm200102153440706 · Cited by 2,041
Bedossa, P. (1994) · Hepatology · doi:10.1002/hep.1840200104 · Cited by 2,003
Cited by
Comparison of Noninvasive Markers of Fibrosis in Patients With Nonalcoholic Fatty Liver Disease
Shah, A. G., Lydecker, A., Murray, K., Tetri, B. N., Contos, M. J., & Sanyal, A. J. (2009) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2009.05.033 · Cited by 1,553
Non-invasive evaluation of liver fibrosis using transient elastography
Castera, L., Forns, X., & Alberti, A. (2008) · Journal of Hepatology · doi:10.1016/j.jhep.2008.02.008 · Cited by 1,430
Schwenzer, N. F., Springer, F., Schraml, C., Stefan, N., Machann, J., & Schick, F. (2009) · Journal of Hepatology · doi:10.1016/j.jhep.2009.05.023 · Cited by 749
Magnetic Resonance Elastography for the Noninvasive Staging of Liver Fibrosis
Huwart, L., Sempoux, C., Vicaut, E., Salameh, N., Annet, L., Danse, E., Peeters, F., ter Beek, L. C., Rahier, J., Sinkus, R., et al. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.03.076 · Cited by 731
Self-citationMagnetic resonance elastography: A review
Mariappan, Y. K., Glaser, K. J., & Ehman, R. L. (2010) · Clinical Anatomy · doi:10.1002/ca.21006 · Cited by 680
Magnetic resonance elastography of liver: Technique, analysis, and clinical applications
Venkatesh, S. K., Yin, M., & Ehman, R. L. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23731 · Cited by 659
Friedrich-Rust, M., Wunder, K., Kriener, S., Sotoudeh, F., Richter, S., Bojunga, J., Herrmann, E., Poynard, T., Dietrich, C. F., Vermehren, J., et al. (2009) · Radiology · doi:10.1148/radiol.2523081928 · Cited by 620
Singh, S., Venkatesh, S. K., Wang, Z., Miller, F. H., Motosugi, U., Low, R. N., Hassanein, T., Asbach, P., Godfrey, E. M., Yin, M., et al. (2015) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2014.09.046 · Cited by 547
Bavu, É., Gennisson, J.-L., Couade, M., Bercoff, J., Mallet, V., Fink, M., Badel, A., Vallet-Pichard, A., Nalpas, B., Tanter, M., et al. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.05.016 · Cited by 415
Shear Wave Spectroscopy for In Vivo Quantification of Human Soft Tissues Visco-Elasticity
Deffieux, T., Montaldo, G., Tanter, M., & Fink, M. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.925077 · Cited by 411
Diagnosis and Quantitation of Fibrosis
Manning, D. S., & Afdhal, N. H. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.03.001 · Cited by 399
Validation of the FIB4 index in a Japanese nonalcoholic fatty liver disease population
Sumida, Y., Yoneda, M., Hyogo, H., Itoh, Y., Ono, M., Fujii, H., Eguchi, Y., Suzuki, Y., Aoki, N., Kanemasa, K., et al. (2012) · BMC Gastroenterology · doi:10.1186/1471-230x-12-2 · Cited by 383
Hepatic MR Elastography: Clinical Performance in a Series of 1377 Consecutive Examinations
Yin, M., Glaser, K. J., Talwalkar, J. A., Chen, J., Manduca, A., & Ehman, R. L. (2016) · Radiology · doi:10.1148/radiol.2015142141 · Cited by 276
Assessment of Liver Viscoelasticity by Using Shear Waves Induced by Ultrasound Radiation Force
Chen, S., Sanchez, W., Callstrom, M. R., Gorman, B., Lewis, J. T., Sanderson, S. O., Greenleaf, J. F., Xie, H., Shi, Y., Pashley, M., et al. (2013) · Radiology · doi:10.1148/radiol.12120837 · Cited by 258
Singh, S., Venkatesh, S. K., Loomba, R., Wang, Z., Sirlin, C., Chen, J., Yin, M., Miller, F. H., Low, R. N., Hassanein, T., et al. (2016) · European Radiology · doi:10.1007/s00330-015-3949-z · Cited by 252
Critical comparison of elastography methods to assess chronic liver disease
Friedrich-Rust, M., Poynard, T., & Castera, L. (2016) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2016.86 · Cited by 245
Tang, A., Cloutier, G., Szeverenyi, N. M., & Sirlin, C. B. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.15.14552 · Cited by 216
“Publications using investigational implementations have reported additional parameters, such as storage (G′) and loss modulus (G′′) [39] or elasticity and viscosity, by assuming a Kelvin-Voigt model [50].”
Non-invasive diagnosis of advanced fibrosis and cirrhosis
Sharma, S. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i45.16820 · Cited by 215
Wang, Y., Ganger, D. R., Levitsky, J., Sternick, L. A., McCarthy, R. J., Chen, Z. E., Fasanati, C. W., Bolster, B., Shah, S., Zuehlsdorff, S., et al. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.4580 · Cited by 212
“[12] showed similar high sensitivity of 98% and 95% and specificity of 100% and 100% for discrimination, although relatively lower cutoff values of 2.”
BackgroundResultYasaka, K., Akai, H., Kunimatsu, A., Abe, O., & Kiryu, S. (2018) · Radiology · doi:10.1148/radiol.2017171928 · Cited by 204
Liver fibrosis: Review of current imaging and MRI quantification techniques
Petitclerc, L., Sebastiani, G., Gilbert, G., Cloutier, G., & Tang, A. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25550 · Cited by 200
Rizzo, L., Calvaruso, V., Cacopardo, B., Alessi, N., Attanasio, M., Petta, S., Fatuzzo, F., Montineri, A., Mazzola, A., L'abbate, L., et al. (2011) · American Journal of Gastroenterology · doi:10.1038/ajg.2011.341 · Cited by 200
Advanced MRI Methods for Assessment of Chronic Liver Disease
Taouli, B., Ehman, R. L., & Reeder, S. B. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2601 · Cited by 197
Tang, A., Cloutier, G., Szeverenyi, N. M., & Sirlin, C. B. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.15.14553 · Cited by 197
“Commercial MR elastography typically uses a frequency of 60 Hz, although frequencies between 40 and 200 Hz have been investigated for clinical liver imaging [51–55].”
BackgroundWatanabe, H., Kanematsu, M., Goshima, S., Kondo, H., Onozuka, M., Moriyama, N., & Bae, K. T. (2011) · Radiology · doi:10.1148/radiol.10100621 · Cited by 189
Chen, J., Yin, M., Talwalkar, J. A., Oudry, J., Glaser, K. J., Smyrk, T. C., Miette, V., Sandrin, L., & Ehman, R. L. (2017) · Radiology · doi:10.1148/radiol.2016160685 · Cited by 175
Castera, L. (2009) · Journal of Viral Hepatitis · doi:10.1111/j.1365-2893.2009.01087.x · Cited by 172
Viscoelasticity in natural tissues and engineered scaffolds for tissue reconstruction
Huang, D., Huang, Y., Xiao, Y., Yang, X., Lin, H., Feng, G., Zhu, X., & Zhang, X. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.08.013 · Cited by 168
General review of magnetic resonance elastography
Low, G. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i1.59 · Cited by 123
Metadata
- Authors
- Huwart, L., Sempoux, C., Salameh, N., Jamart, J., Annet, L., Sinkus, R., Peeters, F., ter Beek, L. C., Horsmans, Y., & Van Beers, B. E.
- Venue
- Radiology
- Published
- 2007-11
- Volume
- 245
- Issue
- 2
- Pages
- 458-466
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2149796769
- Cited by
- 365
- References
- 44
- FWCI
- 13.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.