Meta-Analysis of MR Imaging in the Diagnosis of Breast Lesions
Abstract
PURPOSE: To determine, in a meta-analysis, the diagnostic performance of contrast material-enhanced magnetic resonance (MR) imaging in patients with breast lesions. MATERIALS AND METHODS: Studies to assess the diagnostic performance of MR imaging in patients suspected of having breast cancer who underwent MR imaging and biopsy from January 1985 through March 2005 were reviewed for inclusion. A summary receiver operating characteristic curve was constructed, and pooled weighted estimates of sensitivity and specificity were calculated by using the recently developed bivariate approach for diagnostic meta-analysis. RESULTS: Of 251 eligible studies, 44 were included in the meta-analysis (sample size range, 14-821; cancer prevalence, 23%-84%). Pooled weighted estimates of sensitivity and specificity were 0.90 (95% confidence interval: 0.88, 0.92) and 0.72 (95% confidence interval: 0.67, 0.77), respectively. The performance of breast MR imaging was influenced by the prevalence of cancer in the studied population (P = .05) and by whether two criteria (ie, morphology, enhancement, and kinetic enhancement pattern)--versus one or three criteria--were used to differentiate benign from malignant lesions (P = .02). CONCLUSION: MR imaging of the breast has high sensitivity and lower specificity in the evaluation of breast lesions. SUPPLEMENTAL MATERIAL: http://radiology.rsnajnls.org/cgi/content/full/2461061298/DC1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No adjustments are needed for multiple comparisons.
Rothman, K. J. (1990) · Epidemiology · doi:10.1097/00001648-199001000-00010 · Cited by 5,965
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Reitsma, J. B., Glas, A. S., Rutjes, A. W. S., Scholten, R. J. P. M., Bossuyt, P. M., & Zwinderman, A. H. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.02.022 · Cited by 3,369
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
The diagnostic odds ratio: a single indicator of test performance
Glas, A. S., Lijmer, J. G., Prins, M. H., Bonsel, G. J., & Bossuyt, P. M. M. (2003) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(03)00177-x · Cited by 2,261
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
What to add to nothing? Use and avoidance of continuity corrections in meta‐analysis of sparse data
J. Sweeting, M., J. Sutton, A., & C. Lambert, P. (2004) · Statistics in Medicine · doi:10.1002/sim.1761 · Cited by 1,734
Kriege, M., Brekelmans, C. T. M., Boetes, C., Besnard, P. E., Zonderland, H. M., Obdeijn, I. M., Manoliu, R. A., Kok, T., Peterse, H., Tilanus-Linthorst, M. M. A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa031759 · Cited by 1,687
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405
Do multiple outcome measures require p-value adjustment?
Feise, R. J. (2002) · BMC Medical Research Methodology · doi:10.1186/1471-2288-2-8 · Cited by 1,299
Kuhl, C. K., Mielcareck, P., Klaschik, S., Leutner, C., Wardelmann, E., Gieseke, J., & Schild, H. H. (1999) · Radiology · doi:10.1148/radiology.211.1.r99ap38101 · Cited by 1,277
Kuhl, C. K., Schrading, S., Leutner, C. C., Morakkabati-Spitz, N., Wardelmann, E., Fimmers, R., Kuhn, W., & Schild, H. H. (2005) · Journal of Clinical Oncology · doi:10.1200/jco.2004.00.4960 · Cited by 1,147
Breast Carcinoma: Effect of Preoperative Contrast-enhanced MR Imaging on the Therapeutic Approach
Fischer, U., Kopka, L., & Grabbe, E. (1999) · Radiology · doi:10.1148/radiology.213.3.r99dc01881 · Cited by 664
Harms, S. E., Flamig, D. P., Hesley, K. L., Meiches, M. D., Jensen, R. A., Evans, W. P., Savino, D. A., & Wells, R. V. (1993) · Radiology · doi:10.1148/radiology.187.2.8475297 · Cited by 634
Boetes, C., Mus, R. D., Holland, R., Barentsz, J. O., Strijk, S. P., Wobbes, T., Hendriks, J. H., & Ruys, S. H. (1995) · Radiology · doi:10.1148/radiology.197.3.7480749 · Cited by 519
Magnetic Resonance Imaging of the Breast Prior to Biopsy
Bluemke, D. A. (2004) · JAMA · doi:10.1001/jama.292.22.2735 · Cited by 513
FLETCHER, R. H. (1986) · Annals of Internal Medicine · doi:10.7326/0003-4819-104-1-66 · Cited by 473
Meta-analytic methods for diagnostic test accuracy
Irwig, L., Macaskill, P., Glasziou, P., & Fahey, M. (1995) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(94)00099-c · Cited by 467
Buadu, L. D., Murakami, J., Murayama, S., Hashiguchi, N., Sakai, S., Masuda, K., Toyoshima, S., Kuroki, S., & Ohno, S. (1996) · Radiology · doi:10.1148/radiology.200.3.8756909 · Cited by 465
Estimating Diagnostic Accuracy from Multiple Conflicting Reports: A New Meta-analytic Method
Littenberg, B., & Moses, L. E. (1993) · Medical Decision Making · doi:10.1177/0272989x9301300408 · Cited by 434
Boetes, C., Barentsz, J. O., Mus, R. D. M., van der Sluis, R. F., van Erning, L. J. T. O., Hendriks, J. H. C. L., Holland, R., & Ruys, S. H. (1994) · Radiology · doi:10.1148/radiology.193.3.7972823 · Cited by 377
Factors affecting sensitivity and specificity of exercise electrocardiography
Hlatky, M. A., Pryor, D. B., Harrell, F. E., Califf, R. M., Mark, D. B., & Rosati, R. A. (1984) · The American Journal of Medicine · doi:10.1016/0002-9343(84)90437-6 · Cited by 371
Staging of symptomatic primary breast cancer with MR imaging.
Mumtaz, H., Hall-Craggs, M. A., Davidson, T., Walmsley, K., Thurell, W., Kissin, M. W., & Taylor, I. (1997) · American Journal of Roentgenology · doi:10.2214/ajr.169.2.9242745 · Cited by 291
Kinkel, K., Helbich, T. H., Esserman, L. J., Barclay, J., Schwerin, E. H., Sickles, E. A., & Hylton, N. M. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.175.1.1750035 · Cited by 219
Detection of Breast Malignancy: Diagnostic MR Protocol for Improved Specificity
Huang, W., Fisher, P. R., Dulaimy, K., Tudorica, L. A., O’Hea, B., & Button, T. M. (2004) · Radiology · doi:10.1148/radiol.2322030547 · Cited by 219
Update of Breast MR Imaging Architectural Interpretation Model
Nunes, L. W., Schnall, M. D., & Orel, S. G. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma44484 · Cited by 208
Moons, K. G. M., van Es, G.-A., Deckers, J. W., Habbema, J. D. F., & Grobbee, D. E. (1997) · Epidemiology · doi:10.1097/00001648-199701000-00002 · Cited by 189
Self-citationCecil, K. M., Schnall, M. D., Siegelman, E. S., & Lenkinski, R. E. (2001) · Breast Cancer Research and Treatment · doi:10.1023/a:1017911211090 · Cited by 164
Hulka, C. A., Edmister, W. B., Smith, B. L., Tan, L., Sgroi, D. C., Campbell, T., Kopans, D. B., & Weisskoff, R. M. (1997) · Radiology · doi:10.1148/radiology.205.3.9393545 · Cited by 160
Three-dimensional RODEO breast MR imaging of lesions containing ductal carcinoma in situ.
Soderstrom, C. E., Harms, S. E., Copit, D. S., Evans, W. P., Savino, D. A., Krakos, P., Farrell, R. S., & Flamig, D. P. (1996) · Radiology · doi:10.1148/radiology.201.2.8888235 · Cited by 152
Daldrup-Link, H. E., Rydland, J., Helbich, T. H., Bjørnerud, A., Turetschek, K., Kvistad, K. A., Kaindl, E., Link, T. M., Staudacher, K., Shames, D. M., et al. (2003) · Radiology · doi:10.1148/radiol.2293021045 · Cited by 79
Clustered Breast Microcalcifications: Evaluation by Dynamic Contrast-Enhanced Subtraction MRI
Gilles, R., Meunier, M., Lucidarme, O., Sigal‐Zafrani, B., Guinebretière, J., Tardivon, A. A., Gal, M. L., Vanel, D., Neuenschwander, S., & Arriagada, R. (1996) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199601000-00003 · Cited by 75
Cited by
Magnetic resonance imaging of the breast: Recommendations from the EUSOMA working group
Sardanelli, F., Boetes, C., Borisch, B., Decker, T., Federico, M., Gilbert, F. J., Helbich, T., Heywang-Köbrunner, S. H., Kaiser, W. A., Kerin, M. J., et al. (2010) · European Journal of Cancer · doi:10.1016/j.ejca.2010.02.015 · Cited by 992
Ultrasound Imaging Technologies for Breast Cancer Detection and Management: A Review
Guo, R., Lu, G., Qin, B., & Fei, B. (2018) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.09.012 · Cited by 542
Sardanelli, F., Podo, F., Santoro, F., Manoukian, S., Bergonzi, S., Trecate, G., Vergnaghi, D., Federico, M., Cortesi, L., Corcione, S., et al. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e3181f3fcdf · Cited by 337
Peters, N. H. G. M., van Esser, S., van den Bosch, M. A. A. J., Storm, R. K., Plaisier, P. W., van Dalen, T., Diepstraten, S. C. E., Weits, T., Westenend, P. J., Stapper, G., et al. (2011) · European Journal of Cancer · doi:10.1016/j.ejca.2010.11.035 · Cited by 326
Self-citationCurrent State of Breast Cancer Diagnosis, Treatment, and Theranostics
Bhushan, A., Gonsalves, A., & Menon, J. U. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13050723 · Cited by 298
Metadata
- Authors
- Peters, N. H. G. M., Borel Rinkes, I. H. M., Zuithoff, N. P. A., Mali, W. P. T. M., Moons, K. G. M., & Peeters, P. H. M.
- Venue
- Radiology
- Published
- 2008-01
- Volume
- 246
- Issue
- 1
- Pages
- 116-124
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2013703224
- Cited by
- 529
- References
- 35
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.