The “Laboratory” Effect: Comparing Radiologists' Performance and Variability during Prospective Clinical and Laboratory Mammography Interpretations
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE: To compare radiologists' performance during interpretation of screening mammograms in the clinic with their performance when reading the same mammograms in a retrospective laboratory study. MATERIALS AND METHODS: This study was conducted under an institutional review board-approved, HIPAA-compliant protocol; the need for informed consent was waived. Nine experienced radiologists rated an enriched set of mammograms that they had personally read in the clinic (the "reader-specific" set) mixed with an enriched "common" set of mammograms that none of the participants had previously read in the clinic by using a screening Breast Imaging Reporting and Data System (BI-RADS) rating scale. The original clinical recommendations to recall the women for a diagnostic work-up, for both reader-specific and common sets, were compared with their recommendations during the retrospective experiment. The results are presented in terms of reader-specific and group-averaged sensitivity and specificity levels and the dispersion (spread) of reader-specific performance estimates. RESULTS: On average, the radiologists' performance was significantly better in the clinic than in the laboratory (P = .035). Interreader dispersion of the computed performance levels was significantly lower during the clinical interpretations (P < .01). CONCLUSION: Retrospective laboratory experiments may not represent either expected performance levels or interreader variability during clinical interpretations of the same set of mammograms in the clinical environment well.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Cited by
Rodriguez-Ruiz, A., Lång, K., Gubern-Merida, A., Broeders, M., Gennaro, G., Clauser, P., Helbich, T. H., Chevalier, M., Tan, T., Mertelmeier, T., et al. (2019) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djy222 · Cited by 692
“Therefore, the human performance was affected by a “laboratory effect” that reflects the reading of enriched datasets (46,47).”
BackgroundDetection of Breast Cancer with Mammography: Effect of an Artificial Intelligence Support System
Rodríguez-Ruiz, A., Krupinski, E., Mordang, J.-J., Schilling, K., Heywang-Köbrunner, S. H., Sechopoulos, I., & Mann, R. M. (2019) · Radiology · doi:10.1148/radiol.2018181371 · Cited by 602
Kim, H.-E., Kim, H. H., Han, B.-K., Kim, K. H., Han, K., Nam, H., Lee, E. H., & Kim, E.-K. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30003-0 · Cited by 525
Digital Breast Tomosynthesis: Observer Performance Study
Gur, D., Abrams, G. S., Chough, D. M., Ganott, M. A., Hakim, C. M., Perrin, R. L., Rathfon, G. Y., Sumkin, J. H., Zuley, M. L., & Bandos, A. I. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.2031 · Cited by 363
Self-citationSechopoulos, I., Teuwen, J., & Mann, R. (2021) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2020.06.002 · Cited by 341
Freeman, K., Geppert, J., Stinton, C., Todkill, D., Johnson, S., Clarke, A., & Taylor-Phillips, S. (2021) · BMJ · doi:10.1136/bmj.n1872 · Cited by 338
Carter, S. M., Rogers, W., Win, K. T., Frazer, H., Richards, B., & Houssami, N. (2020) · The Breast · doi:10.1016/j.breast.2019.10.001 · Cited by 312
Conant, E. F., Toledano, A. Y., Periaswamy, S., Fotin, S. V., Go, J., Boatsman, J. E., & Hoffmeister, J. W. (2019) · Radiology: Artificial Intelligence · doi:10.1148/ryai.2019180096 · Cited by 241
Evans, K. K., Birdwell, R. L., & Wolfe, J. M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0064366 · Cited by 236
“(2008) reported a change in confidence ratings with prevalence that would be consistent with a criterion shift and, as noted above, criterion shifts have been a hallmark of prevalence effects outside radiology [15].”
BackgroundMethodPellacani, G., Pepe, P., Casari, A., & Longo, C. (2014) · British Journal of Dermatology · doi:10.1111/bjd.13148 · Cited by 197
Wallis, M. G., Moa, E., Zanca, F., Leifland, K., & Danielsson, M. (2012) · Radiology · doi:10.1148/radiol.11103514 · Cited by 187
Analysis of Perceptual Expertise in Radiology – Current Knowledge and a New Perspective
Waite, S., Grigorian, A., Alexander, R. G., Macknik, S. L., Carrasco, M., Heeger, D. J., & Martinez-Conde, S. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00213 · Cited by 170
Pacilè, S., Lopez, J., Chone, P., Bertinotti, T., Grouin, J. M., & Fillard, P. (2020) · Radiology: Artificial Intelligence · doi:10.1148/ryai.2020190208 · Cited by 161
“First, it was enriched with cancer cases and because readers were aware of that fact, this could have caused a laboratory effect, inducing a high rate of false-positive assessments (29,30).”
BackgroundRams, hounds and white boxes: investigating human–AI collaboration protocols in medical diagnosis
Cabitza, F., Campagner, A., Ronzio, L., Cameli, M., Mandoli, G. E., Pastore, M. C., Sconfienza, L. M., Folgado, D., Barandas, M., & Gamboa, H. (2023) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2023.102506 · Cited by 117
Evaluating Imaging and Computer-aided Detection and Diagnosis Devices at the FDA
Gallas, B. D., Chan, H.-P., D’Orsi, C. J., Dodd, L. E., Giger, M. L., Gur, D., Krupinski, E. A., Metz, C. E., Myers, K. J., Obuchowski, N. A., et al. (2012) · Academic Radiology · doi:10.1016/j.acra.2011.12.016 · Cited by 81
“For an example of a pilot study informing a pivotal study, see the work of Gur et al (44) and Good et al (90).”
BackgroundInfluentialSelf-citationCabitza, F., & Zeitoun, J.-D. (2019) · Annals of Translational Medicine · doi:10.21037/atm.2019.04.07 · Cited by 72
“Laboratory (46) or Hawthorne effects can be common in different experimental settings, while pragmatic and ecological validity require testing and validation in real-world conditions and hospital routines.”
BackgroundRadiology-GPT: A Large Language Model for Radiology
Liu, Z., Zhong, A., Li, Y., Yang, L., Ju, C., Wu, Z., Ma, C., Shu, P., Chen, C., Kim, S., et al. (2023) · arXiv · doi:10.48550/arxiv.2306.08666 · Cited by 59
“There could be significant variations in how different radiologists interpret the same set of radiology findings [39, 40, 41].”
Cabitza, F., Campagner, A., Angius, R., Natali, C., & Reverberi, C. (2023) · Proceedings of the 2023 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3544548.3581095 · Cited by 51
“Indeed, whereas absolute accuracy can be afected by experimental conditions, for a sort of Hawthorne or laboratory efect [43, 68], in that real-world performance is generally better, we conjecture that the ratios of AI-human agreement and disagreement would be less prone to changes across diferent conditions.”
BackgroundGeppert, J., Auguste, P., Asgharzadeh, A., Ghiasvand, H., Patel, M., Brown, A., Jayakody, S., Helm, E., Todkill, D., Madan, J., et al. (2025) · Health Technology Assessment · doi:10.3310/jytw8921 · Cited by 22
Metadata
- Authors
- Gur, D., Bandos, A. I., Cohen, C. S., Hakim, C. M., Hardesty, L. A., Ganott, M. A., Perrin, R. L., Poller, W. R., Shah, R., Sumkin, J. H., Wallace, L. P., & Rockette, H. E.
- Venue
- Radiology
- Published
- 2008-10
- Volume
- 249
- Issue
- 1
- Pages
- 47-53
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2153130422
- Cited by
- 186
- References
- 1
- FWCI
- 7.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.