Malignant Liver Tumors: Treatment with Percutaneous Microwave Ablation—Complications among Cohort of 1136 Patients

Liang, Ping, Wang, Yang, Yu, XiaoLing, Dong, Baowei · 2009 · Radiology

Abstract

PURPOSE: To report the complications for percutaneous microwave (MW) ablation for the treatment of malignant liver tumors and the possible risk factors for complications in a large series of patients. MATERIALS AND METHODS: The study was approved by the institutional review board; informed consent was waived because of the retrospective design. Over a 13-year period, 1136 patients with 1928 malignant liver tumors underwent ultrasonographically guided percutaneous MW ablation (583 with a noncooled-shaft antenna and 553 with a cooled-shaft antenna). A total of 3697 MW ablation sessions (average, 1.8 sessions per patient) were performed. Mortality and treatment-related major and minor complications were documented. Data were subsequently analyzed to determine whether the major complication rate was related to antenna type, tumor size, tumor location, or number of MW sessions. RESULTS: Two deaths not directly attributable to MW ablation were encountered. Major complications occurred in 30 (2.6%) patients and included liver abscess and empyema (n = 5), bile duct injury (n = 2), perforation of the colon (n = 2), tumor seeding (n = 5), pleural effusion requiring thoracentesis (n = 12), hemorrhage requiring arterial embolization (n = 1), and skin burn requiring resection (n = 3). Minor complications included fever; pain; asymptomatic pleural effusion, gallbladder wall thickening, and arterioportal shunt; small stricture of the bile duct; and skin burn requiring no treatment. Use of noncooled-shaft antenna and an increased number of MW ablation sessions were associated with a higher rate of major complications (P < .05). CONCLUSION: MW ablation is a well-tolerated technique with an acceptably low rate of major complications for treatment of malignant liver tumors. Use of a cooled-shaft antenna, as well as fewer MW sessions, may help minimize major complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2513081740

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 378

Metadata

Authors
Liang, P., Wang, Y., Yu, X., & Dong, B.
Venue
Radiology
Published
2009-06
Volume
251
Issue
3
Pages
933-940
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2158378333
Cited by
378
References
13
FWCI
9.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Malignant Liver Tumors: Treatment with Percutaneous Microwave Ablation—Complications among Cohort of 1136 Patients. https://app.cochat.ai/papers/10.1148/radiol.2513081740
The paper
Liang, P., Wang, Y., Yu, X., & Dong, B. (2009). Malignant Liver Tumors: Treatment with Percutaneous Microwave Ablation—Complications among Cohort of 1136 Patients. Radiology. https://doi.org/10.1148/radiol.2513081740

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.