The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Malignant Liver Tumors: Treatment with Percutaneous Microwave Ablation—Complications among Cohort of 1136 Patients
Abstract
PURPOSE: To report the complications for percutaneous microwave (MW) ablation for the treatment of malignant liver tumors and the possible risk factors for complications in a large series of patients. MATERIALS AND METHODS: The study was approved by the institutional review board; informed consent was waived because of the retrospective design. Over a 13-year period, 1136 patients with 1928 malignant liver tumors underwent ultrasonographically guided percutaneous MW ablation (583 with a noncooled-shaft antenna and 553 with a cooled-shaft antenna). A total of 3697 MW ablation sessions (average, 1.8 sessions per patient) were performed. Mortality and treatment-related major and minor complications were documented. Data were subsequently analyzed to determine whether the major complication rate was related to antenna type, tumor size, tumor location, or number of MW sessions. RESULTS: Two deaths not directly attributable to MW ablation were encountered. Major complications occurred in 30 (2.6%) patients and included liver abscess and empyema (n = 5), bile duct injury (n = 2), perforation of the colon (n = 2), tumor seeding (n = 5), pleural effusion requiring thoracentesis (n = 12), hemorrhage requiring arterial embolization (n = 1), and skin burn requiring resection (n = 3). Minor complications included fever; pain; asymptomatic pleural effusion, gallbladder wall thickening, and arterioportal shunt; small stricture of the bile duct; and skin burn requiring no treatment. Use of noncooled-shaft antenna and an increased number of MW ablation sessions were associated with a higher rate of major complications (P < .05). CONCLUSION: MW ablation is a well-tolerated technique with an acceptably low rate of major complications for treatment of malignant liver tumors. Use of a cooled-shaft antenna, as well as fewer MW sessions, may help minimize major complications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chen, M.-S., Li, J.-Q., Zheng, Y., Guo, R.-P., Liang, H.-H., Zhang, Y.-Q., Lin, X.-J., & Lau, W. Y. (2006) · Annals of Surgery · doi:10.1097/01.sla.0000201480.65519.b8 · Cited by 1,432
Livraghi, T., Solbiati, L., Meloni, M. F., Gazelle, G. S., Halpern, E. F., & Goldberg, S. N. (2003) · Radiology · doi:10.1148/radiol.2262012198 · Cited by 1,298
Image-guided Tumor Ablation: Standardization of Terminology and Reporting Criteria
Goldberg, S. N., Grassi, C. J., Cardella, J. F., Charboneau, J. W., Dodd, G. D., Dupuy, D. E., Gervais, D., Gillams, A. R., Kane, R. A., Lee, F. T., et al. (2005) · Radiology · doi:10.1148/radiol.2353042205 · Cited by 1,193
Solbiati, L., Livraghi, T., Goldberg, S. N., Ierace, T., Meloni, F., Dellanoce, M., Cova, L., Halpern, E. F., & Gazelle, G. S. (2001) · Radiology · doi:10.1148/radiol.2211001624 · Cited by 870
Llovet, J. M., Vilana, R., Brú, C., Bianchi, L., Salmeron, J. M., Boix, L., Ganau, S., Sala, M., Pagès, M., Ayuso, C., et al. (2001) · Hepatology · doi:10.1053/jhep.2001.24233 · Cited by 759
Adverse Events During Radiofrequency Treatment of 582 Hepatic Tumors
de Baère, T., Risse, O., Kuoch, V., Dromain, C., Sengel, C., Smayra, T., Din, M. G. E., Letoublon, C., & Elias, D. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.3.1810695 · Cited by 478
Radiofrequency Thermal Ablation of Abdominal Tumors: Lessons Learned from Complications
Rhim, H., Dodd, G. D., Chintapalli, K. N., Wood, B. J., Dupuy, D. E., Hvizda, J. L., Sewell, P. E., & Goldberg, S. N. (2004) · RadioGraphics · doi:10.1148/rg.241025144 · Cited by 304
Microwave Ablation of Hepatocellular Carcinoma
Liang, P., & Wang, Y. (2007) · Oncology · doi:10.1159/000111718 · Cited by 234
Self-citationVogl, T. J., Straub, R., Eichler, K., Woitaschek, D., & Mack, M. G. (2002) · Radiology · doi:10.1148/radiol.2252011171 · Cited by 232
MR-guided laser-induced thermotherapy (LITT) of liver tumours: experimental and clinical data
Vogl, T., Straub, R., Zangos, S., Mack, M. G., & Eichler, K. (2004) · International Journal of Hyperthermia · doi:10.1080/02656730400007212 · Cited by 138
Cited by
Multimodal treatment of hepatocellular carcinoma on cirrhosis: An update
Vivarelli, M. (2013) · World Journal of Gastroenterology · doi:10.3748/wjg.v19.i42.7316 · Cited by 799
Microwave Tumor Ablation: Mechanism of Action, Clinical Results, and Devices
Lubner, M. G., Brace, C. L., Hinshaw, J. L., & Lee, F. T. (2010) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2010.04.007 · Cited by 765
Radiofrequency Ablation and Microwave Ablation in Liver Tumors: An Update
Izzo, F., Granata, V., Grassi, R., Fusco, R., Palaia, R., Delrio, P., Carrafiello, G., Azoulay, D., Petrillo, A., & Curley, S. A. (2019) · The Oncologist · doi:10.1634/theoncologist.2018-0337 · Cited by 578
Percutaneous treatment of hepatocellular carcinoma: State of the art and innovations
Nault, J.-C., Sutter, O., Nahon, P., Ganne-Carrié, N., & Séror, O. (2018) · Journal of Hepatology · doi:10.1016/j.jhep.2017.10.004 · Cited by 395
Poulou, L. S. (2015) · World Journal of Hepatology · doi:10.4254/wjh.v7.i8.1054 · Cited by 340
Metadata
- Authors
- Liang, P., Wang, Y., Yu, X., & Dong, B.
- Venue
- Radiology
- Published
- 2009-06
- Volume
- 251
- Issue
- 3
- Pages
- 933-940
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2158378333
- Cited by
- 378
- References
- 13
- FWCI
- 9.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Malignant Liver Tumors: Treatment with Percutaneous Microwave Ablation—Complications among Cohort of 1136 Patients. https://app.cochat.ai/papers/10.1148/radiol.2513081740
- The paper
- Liang, P., Wang, Y., Yu, X., & Dong, B. (2009). Malignant Liver Tumors: Treatment with Percutaneous Microwave Ablation—Complications among Cohort of 1136 Patients. Radiology. https://doi.org/10.1148/radiol.2513081740
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.