Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 161

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Measurement of Hepatic Lipid: High-Speed T2-Corrected Multiecho Acquisition at1H MR Spectroscopy—A Rapid and Accurate Technique

Pineda, Nashiely, Sharma, Puneet, Xu, Qin, Hu, Xiaoping, Vos, Miriam, Martin, Diego R.·2009·Radiology

Abstract

PURPOSE: To evaluate the feasibility, accuracy, and reproducibility of a fast breath-hold magnetic resonance (MR) spectroscopic method for T2-corrected hepatic lipid measurement in phantoms and in humans. MATERIALS AND METHODS: All experiments were institutional review board approved and HIPAA compliant; informed consent was obtained from all subjects. The 15-second breath-hold high-speed T2-corrected multiecho (HISTO) MR spectroscopic technique was developed to acquire multiple echoes in a single acquisition, which enables the quantification of water and lipid T2, and subsequently to provide a corrected measure of hepatic lipid fraction. The accuracy of T2-corrected MR spectroscopy was evaluated in eight lipid phantoms doped with iron to simulate variable T2 effects. The mean absolute error of the HISTO technique with the known lipid amounts, as well as with uncorrected MR spectroscopic measures, was evaluated. The HISTO sequence was performed in 25 male subjects (mean age, 23.0 years +/- 19.2 [standard deviation]) to evaluate measurement bias with conventional, uncorrected MR spectroscopy. Three additional male subjects (mean age, 30.0 years +/- 1.0) were examined to assess reproducibility by using analysis of variance testing within subject and between separate imaging sessions. RESULTS: The absolute error in quantifying lipid fraction by using iron-doped lipid phantoms was less than 11% for the HISTO technique, compared with more than 50% for uncorrected MR spectroscopy. In the 25 human subjects, hepatic lipid measured by using HISTO differed significantly from that by using uncorrected MR spectroscopic methods by 5.1% +/- 2.6. Analysis of variance of three separate imaging sessions with the HISTO technique indicated no significant variance (P = .13) in three subjects. CONCLUSION: HISTO is an accurate, reproducible MR spectroscopic sequence for quantifying hepatic lipid noninvasively. Evidence has shown this method to be feasible in vivo for clinical use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2523082084

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 161

Metadata

Authors
Pineda, N., Sharma, P., Xu, Q., Hu, X., Vos, M., & Martin, D. R.
Venue
Radiology
Published
2009-08
Volume
252
Issue
2
Pages
568-576
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1982791756
Cited by
161
References
2
FWCI
3.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of Hepatic Lipid: High-Speed T2-Corrected Multiecho Acquisition at1H MR Spectroscopy—A Rapid and Accurate Technique. https://app.cochat.ai/papers/10.1148/radiol.2523082084
The paper
Pineda, N., Sharma, P., Xu, Q., Hu, X., Vos, M., & Martin, D. R. (2009). Measurement of Hepatic Lipid: High-Speed T2-Corrected Multiecho Acquisition at1H MR Spectroscopy—A Rapid and Accurate Technique. Radiology. https://doi.org/10.1148/radiol.2523082084

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.