Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 625

The DOI matches its Crossref record.

Cerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis.

Axel, L·1980·Radiology

Abstract

Dynamic computed tomography (CT) using rapid-sequence scanning can be used to determine cerebral blood flow noninvasively following an intravenous bolus injection of contrast material. Since the contrast material remains intravascular in the normal brain, principles of indicator dilution analysis for nondiffusible indicators are applied to the time course of the changes in contrast concentration. While a delay is introduced by the relatively prolonged intravenous injection, this can be corrected for if the arteries are seen on the scan; the corrected mean transit time of the first passage of the bolus through the vessels gives the blood flow per unit vascular volume. To find the blood flow per unit of total tissue volume requires measuring the concentration of contrast material in the blood, which cannot always be done directly from brain scans with current CT equipment; however, a relative volume for total tissue flow can be found by using the area under the curve of contrast concentration as a function of time, as this area is proportional to the fractional vascular volume of the tissue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.137.3.7003648

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 625

Metadata

Authors
Axel, L.
Venue
Radiology
Published
1980-12
Volume
137
Issue
3
Pages
679-686
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1974125693
Cited by
625
References
0
FWCI
1.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis. https://app.cochat.ai/papers/10.1148/radiology.137.3.7003648
The paper
Axel, L. (1980). Cerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis. Radiology. https://doi.org/10.1148/radiology.137.3.7003648

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.